A Suggestion for Counting Efficiency Management of the Automation Instrument

자동화장비 계측효율 관리적 측정방법 제안

  • Park, Jun Mo (Department of nuclear medicine, Yeouido ST.Mary's hospital Catholic University) ;
  • Kim, Han Chul (Department of nuclear medicine, Yeouido ST.Mary's hospital Catholic University) ;
  • Choi, Seung Won (Department of nuclear medicine, Yeouido ST.Mary's hospital Catholic University)
  • 박준모 (가톨릭대학교 여의도성모병원 핵의학과) ;
  • 김한철 (가톨릭대학교 여의도성모병원 핵의학과) ;
  • 최승원 (가톨릭대학교 여의도성모병원 핵의학과)
  • Received : 2018.10.01
  • Accepted : 2018.10.11
  • Published : 2018.10.31

Abstract

Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.

Keywords

References

  1. 김지나, 안재석, 원우재. 장비정도관리에 Calibrator[I-125] Set 적용. 대한핵의학기술학회지. 2015;19(2):109
  2. Cobra II Series Auto-Gamma counting Systems Reference Manual: R592-R593