• Title/Summary/Keyword: countermeasure method

Search Result 501, Processing Time 0.031 seconds

Influence of Conducting Particle on the Breakdown Phenomena of $SF_6$ gas in Gas Insulated System ([$SF_6$] 가스 절연기기내에 도전성 금속이물 존재시 섬락전압에 미치는 영향)

  • Lee, B.W.;Ham, G.H.;Kim, I.S.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1687-1689
    • /
    • 1998
  • In this work, the behaviours of conducting wire type particles within the coaxial electrode gap energized with high ac voltage have been systematically investigated using charge simulation method. For this, spheroidal charge is adopted as a image charge for the CSM analysis in order to calculate the acquired charge of the particles which are erected on the surface of the outer electrode. For this purpose, the effects of the lengths and diameters of Cu, Al particles in gas insulated system have been studied by a numerical computation and particle lifting voltage, lifting field, breakdown voltage, acquired charge and travelling distance have been considered. From this, we understand that the particle behaviours have different characteristics according to the particle lengths and diameters. And a possible countermeasure, based on the proposed simulation, has been provided with a view to estimating the flashover voltage of $SF_6$ gas under the 1 atm.

  • PDF

A Study on the Noise Reduction Technology for Air-Compressor (공기압축기 소음 저감 기술에 관한 연구)

  • Kim, Bong-Gi;Kim, Jae-Seung;Kim, Hyeon-Sil;Gang, Hyeon-Ju;Kim, Sang-Ryeol
    • 연구논문집
    • /
    • s.33
    • /
    • pp.39-51
    • /
    • 2003
  • This paper deals with the noise measurement and evaluation method of a reciprocating air-compressor and its noise reduction. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known as motor, belts, suction/discharge valves, moving piston, and flow-induced noise which are caused by edges or discontinuities along the flow path e.g. expansions, contractions, junctions and bends. As a result, it can be found that main noise sources of the air-compressor can be categorized by the suction/discharge noise, valve noise, and compressed-air tank noise. Based on the investigations, mufflers are designed to reduce both the suction/discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, engineering plastics are used as a new one for the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings in the cylinder head. As a result of the countermeasure plans, it can be achieved that the noise reduction of the air-compress is up to 10 dB.

  • PDF

Application of Mobile GIS for Structure Safety and Management (건축물 안전관리를 위한 Mobile GIS의 적용)

  • Yoo, Hwan-Hee;Kang, Sung-Bong;Lee, Sung-Min;Kang, Teack-Sun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.2 s.25
    • /
    • pp.3-9
    • /
    • 2003
  • Recent construction industry is going through much change as getting high-quality, high-technology and environment-friendly, and a safety countermeasure is required urgently as construction structures become larger and more complex. But, Safety management was ignored under quantity-oriented construction policy and that has led to large-scale accidents. Recently, interest for safety management and effective construction of safety management system has been enhanced. Therefore, in this study, we constructed safety management system using Mobile GIS for effective building safety management. As the result, we proposed a method which can manage buildings quickly and effectively as performing data accessibility, storage, and analysis directly in the field.

  • PDF

Drought Index Calculation for Irrigation Reservoirs (관개용 저수지의 한발지수산정)

  • 김선주;이광야;신동원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.6
    • /
    • pp.103-111
    • /
    • 1995
  • Drought index calculation based on the principal hydrological parameters, such as rainfall and reservoir storage, can estimate the duration and intensity of drought in irrigation reservoirs. It is difficult to build up a drought criteria since the conditions change variously by the reliability of rainfall. Because of the increasing water demands, it is urgent to prepare a generalized positive countermeasure to overcome drought. Water demands can at calculated but the estimation of drought characteristics, and the effective water management method can be established. The purpose of this study is to obtain a drought index and build up a data-base on the reservoir basins for establishing the fundamental hydrological data-base. This Index can observe the behavior of the WSI(Water Supply Index) and the component indices. The results summarized through this study are as follows. 1. WSI value of zero does not correspond to 100% in average due to the skewness in the probability distributions. 2. WSI is not a linear index; that is, given change in terms of water volume or percentage of average does not result in a proportional change on the WSI scale. 3. WSI is not always between the reservoir and the rainfall index in magnitude. This is only true if the component indices are of opposite sign. If they are of the same sign, the SWSI will often have a mangitude greater than either of the component indices. This is easily understood, because the concurrence of extreme values of the same sign for the two components is rarer than the occurrence of extreme values for either of the two components individually.

  • PDF

Preventing disaster system of the subaqueous tunnel under the Han river in the Bundang railway (분당선 한강 하저터널의 방재시스템)

  • Kim Yong-Il;Hwang Nak-Yeon;Yoon Young-Hoon;Jie Hong-Keun;Jang Sung-Wook;Kim Dong-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.308-327
    • /
    • 2004
  • As use of tunnels and subways increase there also are accidents proportionate to it. Daegu Subway Station fire, Hongjimoon tunnel fire led people to be conscious of disaster protection and as a result, there is a trend to adopt standards for fire protection. Accordingly, this thesis is focused on investigating various fire and water protection related issues for subaqueous tunnel under Ran river. The thesis developed evacuation and disaster prevention plan as fire level increases and have identified the suitability of disaster prevention through evacuation and fire simulation, countermeasure of a water leakage during construction and operation considering the subaqueous tunnel. And we selected EPB shield TBM equipment considering the ground condition and effect of boring hole, and accomplished reasonable water protection design through setting goals using event-tree method, as well as examining model test of boring hole and flooding in heavy rain. Also included structured total system consist of water leakage sensing system, water protection gate, pumping system and fire protection system to respond systematically in emergency.

  • PDF

Flood Discharge Analysis on Land Use Changes in Han Stream, Jeju Island (토지이용변화에 따른 한천유역의 홍수유출 변동 분석)

  • Yang, Se-Chang;Yang, Sung-Kee;Lee, Jun-Ho;Jung, Woo-Yul;Ko, Kwang-Hyo
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.425-435
    • /
    • 2015
  • A number of projects for development have been done continuously due to the increase of tourist in Jeju Island. However flood disaster countermeasure due to urbanization is not considered during this development projects. This study is to make basic process for the flood estimation in Han stream of Jeju Island. The variation of stream discharge due the every 5 years' land use change from 1980 to 2005. Data for flood events (rainfall and discharge) were collected for HEC-HMS model. Clark method was used for unit hydrograph analysis. For the estimation of Clark unit hydrograph parameters, Kraven II and Sabol's empirical equations were applied. The peak discharge increased 9.9~33.67% and total discharge amount increased 12.53~30.21%. Also, time of concentration for peak discharge was reduced by 10 minutes for each event.

A Study on Fabrication and Evaluation of Ferrite Electromagnetic Wave Absorber

  • Kim, Dong-Il;Bae, Jae-Young;Son, June-Young;Won, Young-Soo;Song, Jae-Man
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.95-99
    • /
    • 2001
  • According to the progress of the electronic industy and radio communication technologies, mankind might enjoy its abundant life On the other hand, many social problems such as EMI, and unnecessary electromagnetic wave occur due to the increased use of electromagnetic wave. Therefore, the organiztions such as CISPR, FCC, ANSl,etc. have provided the standard of electromagnetic wave enviroment for the countermeasure of the EMC. It had been required that the absorbing ability of an electromagnetic wave absorber is more than 20 dB, the bandwidth of which is required through 30 MHz to 1,000 MHz for satisfying the international standard about an anechoic chamber for EMI/EMS measurment. From November of 1998, however, the CISPRll has accepted the extended frequency band from 1 GHz to 18 GHz additionally in the bandwidth of EMI measurementent$^{[1]}$ . In this paper, we proposed a new type absorber satisfying the above requirements and carried out broadband design using the equivalent material constants method. Futheremore, the experiments were carried out over the frequency band from 30 MHz to 2 GHz, and hence, the validity of the proposed design theory was confirmed.

  • PDF

A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing (대변기 세정시 발생하는 배수소음의 특성변화에 관한 연구)

  • Soul, Soo-Hwan;Jung, Chul-Woon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.789-796
    • /
    • 2007
  • It has been noted, in case of the apartments in collective form, the drainage noise from cleaning of toilet causes many problems in the basement and adjacent rooms, mainly hampering the pleasant housing environment. The problems are increasingly raised by civil complaints with the public offices. Therefore, if the drainage noise generates when wash out of toilet bowl is grasped how the characteristics change according to the sorts of drainpipe, it is considered that the establishment of an effective sound insulation countermeasure could be possible when a civil petition against the drainage noise of apartment house is submitted hereafter. On such viewpoint, this study measured and analyzed the characteristics of drainage noise per the type of drainage pipe, according to KS A ISO $1996-1{\sim}3$, with the horizontal branch pipe and riser pipes in the drainage noise experiment chamber which has the characteristics of the anechoic room. In the result, the pipe type with excellent noise reduction function. The result of this study is considered to become available as fundamental data, to take actions on reduction of drainage noise of the ceiling piping method.

Simulation of 1993 East Sea Tsunami by Parallel FEM Model (병렬 FEM 모형을 이용한 1993년 동해 지진해일 시뮬레이션)

  • Hong, Sung-Jin;Choi, Byung-Ho;Pelinovsky, Efim
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.3 s.49
    • /
    • pp.35-45
    • /
    • 2006
  • The simulation of tsunami using detailed bathymetry and topography is required to establish the countermeasure of disaster mitigation and the tsunami hazard map. In this study, a simulation of the 1993 tsunami event in the East Sea using parallel finite element model, which is possible to simulate with suitable accuracy by the Beowulf parallel computation method, is performed to produce detailed features of coastal inundation. Results of simulation are compared with measured data. The evolution of statistic distribution of tsunami heights is studied numerically and the distribution functions of tsunami heights show a tendency to the log-normal curve along coastal area.

The Building for Standard Specification DB of Urban Transit System Infrastructure used by Computer Design Tool (전산지원도구를 이용한 도시철도시설 표준사양 DB 구축 연구)

  • Lee, Woo-Dong;Park, Kee-Jun;Chung, Jong-Duk
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.791-795
    • /
    • 2006
  • Urban transit is one of the most effective ways for efficient operation and construction of an urban transit by composition system which is liked originally such as rolling-stock, power, signal and infrastructure. Urban rail transit system is running in domestic, imports major equipments from advanced countries and setup for maintenance. But it takes long time because it does each organizations and lines. Also, signal, power and track system apply different standard by each construction organizations it causes an increasing construction of cost accordingly it desperately needs a systematic countermeasure. Therefore standard specification of urban transit have been establishing and operatingfor efficient operation of urban transit and base technology security that is populace ride to become a base of state economy. After track, power and signal system will be announced. Standard specification become more, the importance of administrationof standards is emphasized more. Specification administrator’s the importance which use a computing support tool recently in railroad part in embossed and is predicted to be more such forward. Therefore we propose the effective method of management with track, power signal system by constructed data-base system.

  • PDF