• 제목/요약/키워드: cortical surface

검색결과 162건 처리시간 0.029초

$PerioTest^{(R)}$를 이용한 임플란트 동요도에 관한 임상적 연구 ([ $PERIOTEST^{(R)}$ ] ASSESSMENT OF DENTAL IMPLANT MOBILITY : A CLINCAL STUDY)

  • 김선재;한동후
    • 대한치과보철학회지
    • /
    • 제36권5호
    • /
    • pp.758-771
    • /
    • 1998
  • Assessment of implant mobility is an important and reliable method to clinically evaluate implant stability. PerioTest is a precise and reproducible device that cam dynamically measure the reaction of damping characteristics of peri-implant tissue. The aim of this study is to evaluate the effects of amount of implant surface area, diameter, type, implantation site, degrees of cortical engagement, and length of time in function on PTVs and to find out the most determining factor on PTVs. The results are as follows 1. 5.0mm diameter implants show significantly lower PTV than that of 3.75mm diameter implants. 2. PTV in the mandible is significantly lower than that of the maxilla 3. In the maxilla, there is no significant difference in PTV during the first year of implant function, but during the second year a significant decrease in PTV is noted. 4. In the mandible, there is a significant decrease in PTV during the first and second year of implant function. 5. Implantation site seems to be the most determining factor on PTV among the influencing factors in this study. In conclusion, the amount of implant surface area, type, degrees of cortical engagement had no significant effect on PTV, but installation site and diameter influenced significantly on PTV

  • PDF

4종류 목향류(木香類)의 외부(外部) 및 내부형태(內部形態)와 이화학패턴연구 (A Study on external and internal morphology and pattern analysis in 4 kinds of Mok-Hyaeng Radix)

  • 김홍준;강경식;최고야;김호경;정승일;주영승
    • 한국한의학연구원논문집
    • /
    • 제12권3호통권18호
    • /
    • pp.117-130
    • /
    • 2006
  • The purpose of this study was to introduce the differential standard of Mok-Hyaeng Radix species. We established the classificatory standard according to the external and internal morphology and the pattern in 4 kinds of Mok-Hyaeng Radix. The results follow: 1. On the external morphology, Radix of Vladimiria souliei had a sticky material in the head of roots and it was yellowish white in the cut surface. It attached to teeth during chewing. Radix of Aucklandia lappa (=Saussurea lappa) was dark grayish brown and was grayish brown in the cut surface. It had special odor and was not attache to teeth chewing it. On the other hand, Radix of Inula helenium was dark brown. In the cut surface, cortical layer was different from wood layer. Radix of Aristolochia contorta was yellowish brown. In the cut surface, it was not smooth and cortical layer was different from wood layer. 2. On the internal morphology, Radix of Vladimiria souliei had many fascicular fibers and scattered large oil chambers in the bast ray, xylem ray, and parenchyma. On Radix of Aucklandia lappa (=Saussurea lappa), it was difficult to find out the trace when the cork layer was exfoliated. The cambium formed circle and the large oil chambers were scattered in the phloem and xylem. On the other hand, external cortical layer of Radix of Inula helenium was detached and cambium was formed to indistinct circle and large oil chambers were scattered in the phloem and xylem. On Radix of Arustolochia contorta, the large oil chambers were scattered in the surface later, bast part was relatively broad and cambium formed circle. 3. On the TLC pattern, Radix of Aristolochia contorta, Inula helenium, Aucklandia lappa, and Vladimiria souliei were chromogenic to violet and purple according to sulfuric acid colour pattern, especially faint on Aristolochia contorta. 4. On the pattern analysis of HPLC, we compared the content and the pattern of constunolide and dehydrocostus lactone, Radix of Aucklandia lappa was similar to Radix of Vladimiria souliei and Radix of Aristolochia contorta was similar to Radix of Inula helenium. On the total HPLC component pattern, constunolide and dehydrocostus lactone were similar in all four types, but it showed the Rf 5-6 peak was only in Radix of Aristolochia contorta, not in Radix of Inula helenium, Aucklandia lappa, and Vladimiria souliei. It is considered the results of this study will be furnished the basis to succeeding studies and it is needed to extensive comparative study for the same genus-degree of relatedness.

  • PDF

흰쥐의 위궤양 발생에 미치는 대상회전 제거 및 미주신경 절단의 영향 (Influence of cingulate cortical ablation and vagotomy upon gastric ulceration in rats)

  • 박형진;강숙희;조양혁;김철
    • The Korean Journal of Physiology
    • /
    • 제11권1호
    • /
    • pp.45-50
    • /
    • 1977
  • This study was undertaken to investigate the effect of cingulate cortical ablation upon gastric ulceration, and the pathway through which cingulate cortex exerts the effect. 56 female rats were divided equally into cingulate (cingulate cortical ablation), cingulate-vagal (cingulate cortical ablation and vagotomy), normal control and vagal (vagotomy) groups. Cingulate cortex was ablated through a slit-shaped opening (1 mm in width, 13 mm in length) which was made symmetrically on both sides of, and parallel to, the sagittal suture by removing a bone flap from parietal and frontal bones on each side. Vagus nerves on both sides were transected around the distal end of the esophagus. In the normal control animals, surgical intervention ended with scalp incision. All rats were kept without restraint or food deprivation for 3 weeks after surgery. The stomach of each rat was inflated with 7 ml of physiological saline and then removed under deep anesthesia. The mucosal surface was examined under dissecting microscope for the location, shape and number of ulcers, and then enlarged photograph $(4{\times})$was taken. The incidence of ulcer in each group was counted and the number of ulceration as well as the total area of glandular mucosa were measured on the photograph. Results obtained were as follows: 1. The mean number of ulcer per stomach and the total area of ulcer exprssed as permillage of the total area of glandular mucosa were significantly higher in the cingulate group than the cingulate-vagal, the normal control and the vagal groups. There was no difference among the latter three groups. 2. The incidence of ulcer in the cingulate group was significantly higher than that in the .normal control group and was also higher, though not significantly, than those in the cingulate-vagal and the vagal groups. There was no difference among the normal control, the cingulate-vagal and the vagal groups. It is inferred from the above results that the cingulate cortex exerts an inhibitory influence upon gastric ulceration and that this influence is mediated by controlling the vagal activity.

  • PDF

First Records of Two Aquatic Oxytrichid Ciliates (Ciliophora: Sporadotrichida: Oxytrichidae) from Korea

  • Kwon, Choon-Bong;Shin, Mann-Kyoon
    • Animal Systematics, Evolution and Diversity
    • /
    • 제27권1호
    • /
    • pp.59-65
    • /
    • 2011
  • For investigation of the Korean ciliate fauna, two oxytrichid ciliates, Histriculus histrio (Muller, 1773) and Sterkiella thompsoni Foissner, 1996, were collected from freshwater and brackish waters in South Korea, respectively. These two ciliates are reported for the first time in Korea. Descriptions were based on observations of live and silver stained specimens. Diagnoses of these species are as follows. Histriculus histrio: body is approximately $190{\times}85\;{\mu}m$ in size, almost ellipsoidal in shape, posterior part rather thin and very translucent. Cortical granules are absent. Both marginal rows are almost confluent at the posterior end. Six dorsal kineties are present. Sterkiella thompsoni: body is approximately $140{\times}50\;{\mu}m$ in size. Body margins are usually in parallel. Cortical granules are absent. Invariably, four dorsal kineties are present. Two caudal cirri are located on the dorsal surface. Three ellipsoidal macronuclear nodules are present.

임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석 (Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis)

  • 정재덕;조인호
    • 구강회복응용과학지
    • /
    • 제25권2호
    • /
    • pp.109-123
    • /
    • 2009
  • 임플란트 골유착의 성공과 임플란트 안정성에서 가장 중요한 것은 골의 양과 질이며 안정성을 평가하는 방법 중 하나인 주입회전력도 골질에 영향을 받는다. 임플란트를 식립할 때 모터에서 생긴 힘이 임플란트에 전달되면 임플란트는 회전력(moment)과 축력(axial force)을 갖게 되고 임플란트와 접촉한 골에서는 절삭과 압박 그리고 마찰이 일어나 응력이 생기는데 이 때 측정되는 주입회전력(insertion torque)은 골질에 따라 다양하게 나타난다. 본 연구에서는 임플란트를 하악 소구치 부위 골에 식립하는 것을 가정하여 골질을 치밀골의 두께와 망상골의 밀도 그리고 하방 치밀골 존재 시로 나누고, 골의 응력과 변위를 소탄성 범위의 유한요소법으로 분석하고 유효응력(von Mises stress)과 회전력 그리고 축력을 비교 연구하여 골질이 주입 회전력에 미치는 영향을 평가하였다. 임플란트($Br{\aa}nemark$ MKIII.RP, ${\phi}3.75{\times}10.0mm$, Nobel Biocare, $G{\ddot{o}}teborg$, Sweden) 와 원통형 골모형(${\phi}9.5{\times}12.0mm$)의 유한요소 모형을 설계하고 변수로 상부 치밀골의 두께(0.5 mm, 1.5 mm, 2.5 mm)와 치밀골 하부에 망상골의 밀도($0.85g/cm^3$, $1.11g/cm^3$, $1.25g/cm^3$) 그리고 골모형 하부에 1 mm 두께의 치밀골 유무에 따라 총 7개의 모형을 만들었으며, 임플란트가 식립될 때 발생하는 유효응력과 축력 그리고 회전력을 시간대 별로 비교하였다. 임플란트 플랜지 하연이 골의 상부를 파고드는 300 msec, 중간 정도 들어간 550 msec, 완전히 들어가 플랜지 상면이 골 표면과 일치한 800 msec로 나누어 관찰하였을 때 축력은 500 msec 전후에서, 회전력은 800 msec 전후에서 최대값를 보였으며 유효응력 분포는 서로 비슷하였다. 이 같은 실험 결과를 바탕으로 축력을 영역 별로 비교하여 다음과 같은 결과를 얻었다. 1. $Br{\aa}nemark$ MKIII 임플란트는 플랜지가 골을 파고들 때 축력이 치밀 골에서 가장 높았고, 회전력은 플랜지가 골상부에 걸리어 축력이 급격히 감소한 이후에 최대 회전력을 보였으며, 이 때 유효응력 분포는 플랜지와 접촉하는 골 상부에 집중되었다. 2. 임플란트 식립 시 치밀골의 두께가 두꺼울수록 축력과 회전력이 높게 나타났으며 치밀골의 두께가 축력과 회전력에 가장 큰 영향을 주었다. 3. 치밀골의 두께가 1.5 mm 이상인 경우 망상 골의 밀도가 축력에 미치는 영향은 작았고, 치밀골의 두께가 0.5 mm인 경우 망상골의 밀도가 축력과 회전력에 영향이 있을 것으로 사료되었다. 4. 양측 피질골 존재 시 축력의 합은 상부 피질골의 두께가 같은 다른 경우와 비슷하였으나 부위별 촉력은 골하부에서 양측 피질골 모형이 가장 높았고, 회전력은 하방 피질골과 접촉할 때는 피질골 두께가 같은 다른 모형보다 다소 높으나 최대 회전력은 비슷하였다. 위 결과를 토대로 하악 소구치 부위에 $Br{\aa}nemark$ MKIII 임플란트 식립 시 골질과 관련된 요소 중에 치밀골의 두께가 주입회전력에 가장 큰 영향을 주며 망상골의 밀도를 높이는 술식도 일차적 안정성 증가에 유용할 것으로 사료되는 바이다.

유한요소분석법을 이용한 치근형 임플랜트의 응력분포에 관한 연구 (A STUDY ON THE STRESS ANALYSIS OF THREE ROOT-FORM IMPLANTS WITH FNITE ELEMENT ANALYSIS)

  • 문병화;양재호
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.129-150
    • /
    • 1993
  • Since the restoration or masticatory function is the most important aim of implants, it should be substituted for the role of natural teeth and deliver the stress to the bone under the continous load during function. In natural teeth, stress distribution can be obtained through enamel, dentin and cementum and the elasticity of the periodontal ligament play a role of buffering action. In contrast, implant prosthesis has a very unique characteristics that it delvers the load directly to bone through the implant and superstructure. This fact arise the needs to evaluate the stress distribution of the implant in the mechnical aspects, which has a similar role of natural teeth but different pathway of stress. With 3 kinds of implant in prevalent use, 2 types of experimental PEA implant models were made, axisymmetric and 2-dimensional type. In axisymmetric model, the stiffness of the part including the prosthesis and implant which extrude out of bony surface could be calculated with displacement of the superstructure un er 100N vertical load and then damping effects could be determined through this stiffness. In axisymmetric FEA model, load to the bone could be deduced by evaluation the stress distribution of the designed surface under the 100N vertical force and in 2-dimensional model, 100N eccentric vertical load and 20N horizontal loda. The result are as follows. 1. In every implant, stress to the bone tends to be concenturated on the cortical bone. 2. Though the stress of the cancellous bone is larger at the apex of implants, it is less compared with cortical bone. 3. Under 20N horizontal load, stress of the left and right sides of implant shows a symmetrical pattern. But under 100N eccentric vertical load, loaded side shows much larger stress value. 4. In the 1mm interface, stress distribution among implants tend to have a similar pattern. But under 20N horizontal load apposite side of being loaded shows less stress in IMZ. 5. In the case of screw type implant, stress tends to vary along with screw shape. 6. According to the result determined with microstrain, cancellous bone id generally under the condition of overload, while cortical bone is usually within the limitation of physiologic load. 7. In the Branemark implant, maximum stress to the cortical bone is larger than any other implant except for the condition of 20N horizontal force and 0.05mm interface. 8. Damping effects of implants is maximum in IMZ.

  • PDF

다양한 길이의 two-component 미니 임플란트의 응력분산에 대한 3차원적 유한요소분석 (Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length)

  • 최봄;이동옥;모성서;김성훈;박기호;정규림;;한성호
    • 대한치과교정학회지
    • /
    • 제41권6호
    • /
    • pp.423-430
    • /
    • 2011
  • Objective: To evaluate the extent and aspect of stress to the cortical bone after application of a lateral force to a two-component orthodontic mini-implant (OMI, mini-implant) by using three-dimensional finite element analysis (FEA). Methods: The 3D-finite element models consisted of the maxilla, maxillary first molars, second premolars, and OMIs. The screw part of the OMI had a diameter of 1.8 mm and length of 8.5 mm and was placed between the roots of the upper second premolar and the first molar. The cortical bone thickness was set to 1 mm. The head part of the OMI was available in 3 sizes: 1 mm, 2 mm, and 3 mm. After a 2 N lateral force was applied to the center of the head part, the stress distribution and magnitude were analyzed using FEA. Results: When the head part of the OMI was friction fitted (tapped into place) into the inserted screw part, the stress was uniformly distributed over the surface where the head part was inserted. The extent of the minimum principal stress suggested that the length of the head part was proportionate with the amount of stress to the cortical bone; the stress varied between 10.84 and 15.33 MPa. Conclusions: These results suggest that the stress level at the cortical bone around the OMI does not have a detrimental influence on physiologic bone remodeling.

Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits

  • Park, Eun Young;Sohn, Hae Ok;Kim, Eun-Kyong
    • Journal of Yeungnam Medical Science
    • /
    • 제36권1호
    • /
    • pp.43-49
    • /
    • 2019
  • Background: In the osseointegration of dental implants, the implant surface properties have been reported to be some of the most important critical factors. The effect of implant's surfaces created by resorbable blast media (RBM) followed by laser ablation on bone tissue reactions was examined using the removal torque test and histomorphometric analysis. Methods: Two types of dental implants, RBM-laser implants (experimental group) and RBM implants (control group) (CSM implant system, Daegu, Korea; L=6 mm, diameter=3.75 mm) were placed into the right and left distal femoral metaphysis of 17 adult rabbits. Six weeks after placement, removal torque was measured and histomorphometric analysis was performed. Results: The mean removal torque was $24.0{\pm}10.2Ncm$ and $46.6{\pm}16.4Ncm$ for the control and test specimens, respectively. The experimental RBM-laser implants had significantly higher removal torque values than the control RBM implants (p=0.013). The mean values of total and cortical bone to implant contact (BIC) were respectively $46.3{\pm}10.8%$ and $65.3{\pm}12.5%$ for the experimental group, and $41.9{\pm}18.5%$ and $57.6{\pm}10.6%$ for the control group. The experimental RBM-laser implants showed a higher degree of total and cortical BIC compared with RBM implants, but there was no statistical significance (p=0.482, 0.225). Conclusion: The removal torque and BIC of the test group were higher than those of the control group. In this study, the surface treatment created by RBM treatment followed by laser ablation appears to have a potential in improving bone tissue reactions of dental implants.

치조골 높이가 다른 2개 임플란트 금관의 고정연결 조건에 따른 응력분석 (Stress Analysis on the Splinted Conditions of the Two Implant Crowns with the Different Vertical Bone Level)

  • 전창식;정신영;강동완
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.169-182
    • /
    • 2005
  • The purpose of this study was to compare the stress distribution around the surrounding bone according to the splinted and non-splinted conditions on the finite element models of the two implant crowns with the different vertical bone level. The finite element model was designed with the parallel placement of the two fixtures ($4.0mm{\times}11.5mm$) with reverse buttress thread on the mandibular 1st and 2nd molars. As the bone quality, the inner cancellous bone and the outer 2 mm cortical bone were designed, and the cortical and cancellous bone were assumed to be perfectly bonded to the implant fixture. The splinted model(Model 1) had 2 mm contact surface and the non-splinted model(Model 2) had $8{\mu}m$ gap between two implant crowns. Two group (Splinted and non-splinted) was loaded with 200 N magnitude in the vertical and oblique directions on the loading point position on the central position of the crown, the 2 mm and 4 mm buccal offset point from the central position. Von Mises stress value was recorded and compared in the fixture-bone interface in the bucco-lingual and mesio-distal sections. The results were as follows; 1. In the vertical loading condition of central position, the stress was distributed on the cortical bone and the cancellous bone around the thread of the fixture in the splinted and non-splinted models. In the oblique loading condition, the stress was concentrated toward the cortical bone of the fixture neck, and the neck portion of 2nd molar in the non-splinted model was concentrated higher than that of 1st molar compared to the splinted model. 2. In the 2 mm buccal offset position of the vertical loading compared to the central vertical loading, stress pattern was shifted from apical third portion of the fixture to upper third portion of that. In the oblique loading condition, the stress was distributed over the fixture-bone interface. 3. In the 4 mm buccal offset position of the vertical loading, stress pattern was concentrated on the cortical bone around the buccal side of the fixture thread and shifted from apical third portion of the fixture to upper third portion of that in the splinted and non-splinted models. In the oblique loading, stresses pattern was distributed to the outer position of the neck portion of the fixture thread on the mesio-distal section in the splinted and non-splinted models. Above the results, it was concluded that the direction of loading condition was a key factor to effect the pattern and magnitude of stress over the surrounding bone of the fixture under the vertical and oblique loading conditions, although the type with or without proximal contact did not effect to the stress distribution.

흰쥐의 위궤양 발생에 미치는 뇌해마 제거 및 부신 적출의 영향 (Influence of Hippocampectomy and Adrenalectomy upon Gastric Ulceration in Rats)

  • 김명석;안병태;김철
    • The Korean Journal of Physiology
    • /
    • 제10권2호
    • /
    • pp.39-45
    • /
    • 1976
  • This study was conducted to see whether the hippocampectomy exerted facilitatory influence upon gastric ulceration in animals, and if so, whether the effect of hippocampectomy could be suppressed by adrenalectomy. 107 male rats were divided into 5 groups: rats that had over 90% of their hippocampal tissue removed through an opening on each side of the cerebral cortex(hippocampal group, N=21), rats that received bilateral adrenalectomy(adrenal group, N=29), rats that received adrenalectomy as well as hippocampectomy(hippocampo-adrenal group, N=10), rats that received damage to each side of the cortex over the hippocampus(cortical control group, N=20), and rats that had solely their head skin incised(normal control group, N=27). All rats were kept without restraint or food deprivation until on the 25th day after surgery, the stomach of each rat was inflated with 7ml of physiological saline and then removed under deep anesthesia. The mucosal surface was sketched under dissecting microscope, and enlarged photographs$(4{\times})$ were taken. The percentage of animals developing gastric ulcer in each animal group was calculated, the number of ulcer in each stomach was counted, and the total area of ulceration per stomach was measured on the Photograph with the aid of superimposed graph paper and expressed as permillage of total area of the glandular mucosa. Results obtained were as follows: 1. The percentage of animals developing gastric ulcer was significantly larger in the hippocampal group than they were in the hippocampo-adrenal, the adrenal, the cortical, and the normal control groups. 2. The mean number of ulcer per stomach was significantly larger in the hippocampal group than they were in the adrenal, the cortical control, and the normal control groups, while no significant difference existed between the hippocampal and the hippocampo-adrenal groups. 3. Total area of ulcer per stomach was significantly larger in the hippocampal group than they were in the cortical control and the normal control groups, but no significant differ-ence existed among the hippocampal, the adrenal, and the hippocampo·adrenal groups. 4. All measured values of the adrenal group were not significantly different from those of the hippocampo-adrenal, the cortical control, and the normal control groups. It is inferred from the above results that the hippocampus exerts an inhibitory influence upon gastric ulceration and that the hippocampal influence is mediated only partly through suppression of pituitary·adrenal activity.

  • PDF