Study on the corrosion of A/C condenser in the ship (선박용 해수 열교환방식 A/C 응축기의 부식원인)

  • Baek, S.M.;Yang, J.H.;Kim, K.J.;Moon, K.M.;Lee, M.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.283-284
    • /
    • 2006
  • The ship performs heat exchange using seawater to keep main engine and auxiliary machinery at optimum temperature. In heat exchanger, refrigerant located outside of copper tube is cooled by seawater flowing through inside of copper tube. On the other hand, seawater erosion and corrosion nay occasionally cause the corrosion of the copper tube in A/C(Air Conditioner) condenser. This corrosion of copper tube makes seawater and refrigerant mixed, seriously damaging A/C system. In this study, accordingly, the exact ive mechanism of the corrosion on the condenser entailing serious problems occasional is investigated through the electrochemical polarization experiments on the condenser's component materials. According to the experiments, the corrosive procedures on the copper tube was verified by the fact that passive film of the copper tube surface which is destroyed by the pressure of sucked seawater, is damaged by the corrosive ingredients in the seawater.

  • PDF

Clinical Experience of Stenotic Anastoma of Neck after Reconstuctive Surgery for Corrosive Esophageal Stricture (재수술을 요한 식도재건술 환자의 원인분석과 임상적 고찰)

  • 안욱수
    • Journal of Chest Surgery
    • /
    • v.25 no.2
    • /
    • pp.183-187
    • /
    • 1992
  • Reconstructive surgery for corrosive esophageal stricture was performed in 392 patients at National Medical Center from 1959 to 1990 Between Jan. 1971 and Dec. 1990, 23 cases were experienced stenotic anastoma of neck after reconstructive surgery for corrosive esophageal stricture. The major procedure of esophageal reconstruction was colon interposition without resection of the strictured esophagus except jejunal interposition in 1 case. There were 12 males % 11 females, and mean age was forty years. The caustic materials were 16[70%] alkali and 7[30%] acid. Half of the cases had hypopharyngeal injury. After reconstructed surgery, dysphagia was developed immediate in 65%, from 2 months to 5 months in 31%, and from years in 4%[1 case]. The complications were anastomatic leakage in 13 cases, anastomatic stenosis in 8 cases, graft gangrene in 1 case, and cancer development in 1 case. The therapeutic procedures were end-to-end anstomolis & partial resection of stenotic anastoma in 18 cases, bourgination in 2 cases, and coin interposition with graft removal in 3 cases. The therapeutic results were excellent in 16 cases, mild discomfort in 3 cases, poor in 3 cases, and death in 1 cases.

  • PDF

Surgical Treatment of Benign Esophageal Stricture (양성 식도 협착의 외과적 치료)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.107-114
    • /
    • 1990
  • During a ten-year period from August, 1978 to September, 1989 45 patients with benign esophageal stricture were surgically evaluated. The results are as follows; l. Out of 45 patients, there were 26 males and 19 females ranging from 2 to 70 years of age with a mean of 31.9 years. 2. The most common cause of benign esophageal stricture was corrosive burn due to caustic agents[40 cases, 88.9 %]. Corrosive agents were 15 cases of lye, 22 cases of acid and 3 cases of other agents. Other causes were two cases of esophageal web and each one case of previous surgical result, inflammation and idiopathic mediastinal fibrosis respectively. 3. The most frequent stricture site was whole esophagus as 21 cases[46.7 %] and the next was lower a third thoracic esophagus[10 cases, 25.0%]. 4. In 33 of total 45 cases, colon interposition with right colon was performed without resection of the strictured esophagus except one case which was complicated esophageal cancer. Other procedures were 4 cases esophagogastrostomy with segmental resection, 2 cases of plastic repair and so on. 5. Major postoperative complications which were needed for secondary operation were 5 cases[11.1 %]. [2 cases of stenosis, ileus and ulcer bleeding respectively] Overall mortality rate was 4.4 %.

  • PDF

Evaluation of SCC Susceptibility of Weld HAZ in Structural Steel(I) -material properties and strain rate- (강용접부의 응력부식크랙감수성 평가에 관한 연구 I -재료특성과 변형률 속도-)

  • 임재규;정대식;정세희
    • Journal of Welding and Joining
    • /
    • v.11 no.3
    • /
    • pp.48-60
    • /
    • 1993
  • The cause of corrosion failure found in structures or various components operating in severe corrosive environments has been attributed to stress corrosion cracking(SCC)which is resulting from the combined effects of corrosive environments and static tensile stress. Slow strain rate test (SSRT) provides a rapid reliable method to determine SCC susceptibility of metals and alloys for a broad range of application. The chief advantage of SSRT procedures is that it is much more aggressive in producing SCC than conventional constant strain or constant load tests, so that the testing time is considerably reduced. Therefore, in this paper, the combined effects of material properties and strain rate on the tensile ductility and fracture morphology of parents and weldment for SM45C, SCM440 and SM20C steels were examined and discussed in synthetic sea water. The susceptibility of SCC was the most severe under the strain rate of $1.0{\times}10^{-6} sec^{-1}$, and R.O.A. can be used for parent and maximum load for weldment to evaluate the parameter for SCC susceptibility.

  • PDF

Flexural Strength of Reinforced Concrete T Beams Strengthened with Soffit and Web Fiber Sheets. (섬유시트로 밑면과 옆면이 보강된 T형 철근콘크리트보의 휨 강도)

  • 박대효;이규철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.469-474
    • /
    • 2002
  • Recently fiber sheets are used for strengthening the damaged concrete structures due to its many advantages such as its durability, non-corrosive nature, low weight, ease of application, cost saving, control of crack propagation, strength to thickness ratio, high tensile strength, serviceability and aesthetic. However, the lack of analytical procedures for predicting the nominal moment capacity by the fiber sheet reinforcement leads to difficulties in the effective process of decisions of the factors in the strengthening procedure. In this work, flexural strengthening effects by fiber sheets bonded on soffit and web of the member are theoretically studied for the reinforced concrete T beam. The analytical solutions are compared with experimental results of several references to verify the proposed approach.

  • PDF

Iatrogenic Esophageal Perforation - Patterns of Injury, Presentation, Management, and Outcome - (의인성 식도 파열 - 기전, 치료 및 성적 -)

  • 김영진;이철주;소동문;류한영;노환규;문광덕
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.1
    • /
    • pp.30-35
    • /
    • 1999
  • Between 1994 to 1998, 7 patients had taken emergency operations by iatrogenic esophageal perforation. To evaluate patterns of injury, clinical presentation, and treatment options for patients, we reviewed all the 7 patients who had gotten transmural injury to the esophagus during dilatations or stenting procedures at our hospital. The primary diagnosis of the patients were as followings , two were achalagia and remaining five were corrosive esophageal strictures. Chest pain, fever, tachycardia were the early signs after esophageal perforation. The sites of perforation were thoracic esophagus in all cases and all of them underwent operation within 8 hours of initial injury. There were no postoperative mortality. Complications were developed three cases: stricture of anastomotic site, mediastinitis due to graft failure of colon and pleural empyema.

  • PDF

A Study on Behavior of Novel Non-Metallic Anchoring System for FRP Tendons (FRP 긴장재의 비금속 정착 시스템의 거동에 관한 연구)

  • 서관세;조병완;이계삼;김영진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.983-988
    • /
    • 2000
  • Anchoring systems with structural stability and endurance have been one of the most important elements for PSC structures, especially for the structures using non-corrosive FRP tendons. FRP tendons are in increasing use for underground and coastal structures constantly contacted with fresh water or sea water because of their superiority to metallic ones in corrosion-resistance. In this study new non-metallic anchoring system for FRP tendons has been tested and investigated. The newly developed anchoring system utilizes FRP pipes and HEM (Highly Expansive Mortar). The major factors considered in this experiment were expansive pressure of HEM during its hydration and the strength of GFRP(Glass Fiber Reinforced Plastic) Pipe. Anchoring forces of the new anchoring system were investigated from the pull-out testes. The authors analyzed pull-out procedures of the FRP tendons in the various pipe filled with HEM and suggested an improved idea to develop novel non-metallic anchoring system for FRP tendons

Development of CCPP(Calcium Carbonate Precipitation Potential) calculating program for corrosion control of drinking water distribution system (상수도관 부식방지를 위한 CCPP(Calcium Carbonate Precipitation Potential) 산정 프로그램 개발)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.170-175
    • /
    • 2008
  • In this study, we developed the CCPP calculating program, which is a kind of index and can determine whether calcium carbonate would precipitate or not in pipe line of water distribution system. Through 9 complicated procedures, CCPP can be calculated. Assuming pH of equilibrium as a first trial, compare the right-hand-side result with left-hand-side result. If the percentage difference between the two results is less than a prescribed tolerance, the initial assumption for the assumed equilibrium pH is adequate. If the difference is too large, make a different assumption and repeat until a result within the prescribed tolerance is achieved. Plugging the intermediate results into the final equation, we could compute the CCPP. Using Fortran and Visual Basic languages, we developed the program. As a result of application of the program, the water quality of intaking water of Han River is highly corrosive by the index of CCPP.

Surgical treatment on the stenosis of the esophagus (식도섬책에 대한 외과적 치료)

  • Kim, Geun-Ho;Kim, Yeong-Hak
    • Journal of Chest Surgery
    • /
    • v.22 no.1
    • /
    • pp.134-140
    • /
    • 1989
  • A clinical evaluation was made on total 207 cases of corrosive esophageal stricture after ingestion of various corrosive substances and 173 cases of neoplasms in the esophagus and the cardia. The various complications associated with esophageal corrosion were observed on 28 cases [13.5%] in a total of 207 cases. Pathoanatomic findings of complication may be classified to the five category as follow; [1] stenosis in the pharynx due to adhesion of the epiglottis, [2] esophagobronchial fistula, [3] esophageal perforation with bougienation, [4] necrotic rupture of the esophagus and the stomach, and [5] so-called chronic corrosive gastritis. The comparative studies were done on a total of 165 cases of the various procedures of esophagoplasty to the reconstruction of the esophagus, which consists of antethoracal esophagoplasty with jejunum, retrosternal esophagoplasty with jejunum, retrosternal esophagoplasty with right colon, and retrosternal esophagoplasty with left colon. There is no hard and fast rule in selection of jejunum, right colon or left colon as the transplanting bowel and an operative method either antethoracal or retrosternal approach. When there was no possibility of the complication and no any defect of the anatomical states, one stage retrosternal esophagoplasty using right colon was better in various points of view. The 173 patients of the neoplasm of the esophagus consist of 28 cases of benign tumors and 145 cases of malignant tumors in the esophagus and cardia. 28 cases of benign tumors in the esophagus received the surgical treatment and they obtained with excellent results postoperatively. Of the 145 patients of esophageal carcinoma who received surgical managements, 101 cases [69.6%] were found to be operable and 44 cases [30.3%] were inoperable. Due to the various level of carcinoma in the esophagus, the following different surgical procedure was properly used case by case to get the best results in each case. Esophageal carcinoma in the upper and middle third segment received the total esophagectomy and the reconstruction of the esophagus using right colon by substernal procedure. Esophageal carcinoma in the lower third segment received an esophagojejunostomy in the mediastinum after the resection of lower third segment of the esophagus. Carcinoma in the esophago cardia and the stomach received also an esophagojejunostomy after the resection of the lower third segment of the esophagus and subtotal gastrectomy. For the 44 patients with inoperable carcinoma, the several palliative surgical managements such as gastrostomy or jejunostomy for feeding and esophagojejunostomy for bypass of the lower esophagus and the stomach were properly performed case by case for their maximum improvement.

  • PDF

Pain Control for Hydrofluoric Acid Chemical Burn Using EMLA® creams (EMLA® 연고를 이용한 불산 화학 화상의 통증 조절)

  • Choi, Hwan Jun;Song, Jin Woo;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.113-117
    • /
    • 2009
  • Purpose: Although Hydrofluoric acid(HF) is not a strong acid when compared to other hydrogen halides, it is a feared corrosive and is particularly dangerous at higher concentrations. HF burns are characterized by symptoms, often delayed and localized with diluted HF solutions, to include erythema, edema and severe pain. Pain, a well known symptom following exposure to calcium binding. And, EMLA$^{(R)}$ cream is a topical formulation based upon the eutectic mixture of lidocaine and prilocaine and is used in clinical settings to provide pain relief undergoing superficial surgical procedures. The aim of this study is to evaluate effects of EMLA$^{(R)}$ cream, pain - control dressing on the treatment for HF injury wound. Methods: From June 2007 to June 2008, this study was carried out with 10 patients who had HF partial thickness burns. We were applied topically EMLA$^{(R)}$ cream to injured wound with vaseline gauze and 10% calcium gluconate wet gauze dressings. As a principle, in the emergency treatment, partial or complete removal of the bullae along with copious washing with normal saline was done, depending on the degree of HF invasion of the distal digital extremities. The effect of dressing was investigated by visual analogue pain scale. Results: We therefore reviewed 10 cases of HF - induced pain and pain relief treatment principle. The 10 cases who came to the hospital nearly immediately after the injury healed completely without sequelae and EMLA$^{(R)}$ related complications. Conclusion: Proper initial treatment of HF burns are important, if not promptly recognized and properly treated, for produce serious injury. Topical EMLA$^{(R)}$ cream remain a powerful, new advancement for minimizing HF - related pain during dressing procedures. When used appropriately, topical EMLA$^{(R)}$ cream can provide a safe and effective alternative to other forms of HF - pain control treatment.