• 제목/요약/키워드: corrosion rates

검색결과 272건 처리시간 0.024초

Demonstration of EPRI CHECWORKS Code to Predict FAC Wear of Secondary System Pipings of a Nuclear Power Plant

  • Lee, Sung-Ho;Seong Jegarl;Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • 제31권4호
    • /
    • pp.375-384
    • /
    • 1999
  • The credibility of CHECWORKS FAC model analysis was evaluated for plant application in a model plant chosen for demonstration. The operation condition at each pipe component was defined before the wear rate analysis by plant data base, water chemistry analysis, and network flow analysis. The predicted wear was compared with the measured wear for 57 sample components selected from 43 susceptible line groups analysed. The inspected 57 locations represent components of highest predicted wear in each line group. Both absolute value and relative ranking comparisons indicated reasonable correlations between the predicted and the measured values. Four components showed much higher measured wear rates than the predicted ones in the feed water train from main feed water pump discharge to steam generator, probably due to high hydrazine concentration operation the effect of which had not been incorporated into the CHECWORKS model. The measured wear was higher than the predicted one consistently for components with least susceptibility to FAC. It is believed that the conservatism maintained during UT data analysis dominated the measurement accuracy. A great deal of enhancement is anticipated over the current plant pipe management program when a comprehensive plant pipe management program is implemented based on the model analysis.

  • PDF

Development of Wall-Thinning Evaluation Procedure for Nuclear Power Plant Piping-Part 1: Quantification of Thickness Measurement Deviation

  • Yun, Hun;Moon, Seung-Jae;Oh, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • 제48권3호
    • /
    • pp.820-830
    • /
    • 2016
  • Pipe wall thinning by flow-accelerated corrosion and various types of erosion is a significant and costly damage phenomenon in secondary piping systems of nuclear power plants (NPPs). Most NPPs have management programs to ensure pipe integrity due to wall thinning that includes periodic measurements for pipe wall thicknesses using nondestructive evaluation techniques. Numerous measurements using ultrasonic tests (UTs; one of the nondestructive evaluation technologies) have been performed during scheduled outages in NPPs. Using the thickness measurement data, wall thinning rates of each component are determined conservatively according to several evaluation methods developed by the United States Electric Power Research Institute. However, little is known about the conservativeness or reliability of the evaluation methods because of a lack of understanding of the measurement error. In this study, quantitative models for UT thickness measurement deviations of nuclear pipes and fittings were developed as the first step for establishing an optimized thinning evaluation procedure considering measurement error. In order to understand the characteristics of UT thickness measurement errors of nuclear pipes and fittings, round robin test results, which were obtained by previous researchers under laboratory conditions, were analyzed. Then, based on a large dataset of actual plant data from four NPPs, a quantitative model for UT thickness measurement deviation is proposed for plant conditions.

스테인레스강의 내산화성 향상을 위한 스케일 형성에 관한 연구 (A study on the formation of oxide scale on the stainless steel to improve the oxidation resistance)

  • 김대환;김재철;김길무
    • 한국표면공학회지
    • /
    • 제28권6호
    • /
    • pp.333-342
    • /
    • 1995
  • Stainless steels are widely selected as commercial engineering materials mainly because of their excellent corrosion resistance, oxidation resistance and strength. Because the manufacturing temperature of stainless steels is relatively high, the chemical and physical properties of the oxide film which was formed on the stainless steels are of importance in determining the rate of oxidation and the life of equipment exposed to high temperature oxidizing environments. In this study, the oxidation behavior of S. S. 304 and S. S. 430 added by a small amount of oxygen active elements(each +0.5wt% Hf and Y) was studied to improve oxidation resistance. The results of cyclic and isothermal oxidation on S. S. 304 added by OAE showed relatively poor oxidation resistance due to spallations and cracks of $Cr_2O_3$ layer. But all S. S. 430+0.5wt% OAE maintained constant oxidation rates and stable oxide layers at high temperature environment. Especially S. S. 430+0.5wt% Y formed a $Cr_2O_3$ oxide layer and improved cyclic oxidation resistance preventing loss of protective layers about 1000 hours at $1000^{\circ}C$

  • PDF

증기발생기 급수링 관통손상 원인 및 영향 고찰 (Study on Cause and Effect of SG Feed Water Ring Through-Wall Hole)

  • 이성호;이요섭
    • 한국압력기기공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.61-68
    • /
    • 2015
  • The function of Feed Water Ring is to provide the flow path from Feedwater Nozzle to inside of SG(steam generator). Significant amounts of general FAC on the outside of the Feed Water Ring are not likely due to the low flow velocities in this area. However, on the interior of the Feed Water Ring, there may be areas of local higher flow velocity which could lead to higher FAC rates. These may include the inlet tee from the Feedwater Nozzle into the Feed Water Ring, the areas where the Feed Water Ring changes diameter, and especially the entrance area to the J-Nozzles. In this paper, the results of root cause analysis of through-wall hole observed at domestic WH 51F SG Feed Water Ring and its effect on the integrity and performance of SG are described. And, the maintenance strategy for WH 51F SG Feed Water Ring and the monitoring strategy for Downcomer Feed Water Ring of CE System 80 SG are presented.

Microstructure and Tribological Properties of Ti-Si-C-N Nanocomposite Coatings Prepared by Filtered Vacuum Arc Cathode Deposition

  • Elangovan, T.;Kim, Do-Geun;Lee, Seung-Hun;Kim, Jong-Kuk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.54-54
    • /
    • 2011
  • The demand for low-friction, wear and corrosion resistant components, which operate under severe conditions, has directed attentions to advanced surface engineering technologies. The Filtered Vacuum Arc Cathode Deposition (FVACD) process has demonstrated atomically smooth surface at relatively high deposition rates over large surface areas. Preparation of Ti-Si-C-N nanocomposite coatings on (100) Si and stainless steel substrates with tetramethylsilane (TMS) gas pressures to optimize the film preparation conditions. Ti-S-C-N coatings were characterized using X-ray diffraction, X-ray photoelectron spectroscopy, transmission electron microscopy, nanoindentation, Rockwell C indentation and ball-on-disk wear tests. The XRD results have confirmed phase formation information of TiSiCN coatings, which shows mixing of TiN and TiC structure, corresponding to (111), (200) and (220) planes of TiCN. The chemical composition of the film was investigated by XPS core level spectra. The binding energy of the elements present in the films was estimated using XPS measurements and it shows present of elemental information corresponding to Ti2p, N1s, Si 2p and C1. Film hardness and elastic modulus were measured with a nano-indenter, and film hardness reached 40 GPa. Tribological behaviors of the films were evaluated using a ball-on-disk tribometer, and the films demonstrated properties of low-friction and good wear resistance.

  • PDF

터빈 습분분리재열기 Type-439 스테인리스강 튜브 와전류검사 (Eddy Current Testing of Type-439 S/S Tube of MSR in Turbine System)

  • 이희종;조찬희;정지홍;문균영
    • 한국압력기기공학회 논문집
    • /
    • 제4권2호
    • /
    • pp.50-56
    • /
    • 2008
  • The tubes in heat exchanger are typically made of copper alloy, stainless steel, carbon steel, titanium alloy material. Type-439 ferritic stainless steel is ferromagnetic material, and furnish higher heat transfer rates than austenitic stainless steels and higher resistance to corrosion-induced flaws. Ferritic stainless steel can be found in low-pressure(LP) feedwater heaters and moisture separator reheaters(MSRs) in turbine system. LP feedwater heaters generally utilize thin wall Type-439 stainless steel tubing, whereas MSRs typically employ a heavier wall tubing with integral fins. Service-induced damage can occur on the O.D(outside diameter) surface of Type-439 ferritic stainless steel tubing which is employed for MSRs tubing, and the most typical damage mechanism is vibration-induced tube-to-TSP(tube support plate) wear and fatigue cracking. The wear has been reported that occurs mainly on the OD surface. Accordingly, in this study, we have evaluated the flaw sizing capability of magnetic saturation eddy current technique using magnetic saturation probe and flawed specimen.

  • PDF

금속기 복합재료의 마찰ㆍ마모 특성에 관한 연구 (A Study on the Frictional Abrasion Properties of MMC)

  • 이광영;박원조;허선철
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.171-177
    • /
    • 2002
  • Metal matrix composites had generated a lot of interest in recent times because of significant in specific properties, it was also highlighted as the material of frontier industry because strength, heat-resistant, corrosion-resistant and wear-resistant were superiored. In recent years, the study of metal matrix composite has increased by aluminum alloy. The study is based on the tribological properties of AC4CH that is a part of the mechanical property of metal matrix composites. Metal matrix composite that is produced from matrix material AC4CH and reinforcement SiO$_2$, Al$_2$O$_3$ and TiO$_2$ are added to the metal matrix composite fur strength so binding among the whisker can take place. Each metal matrix composite is produced using the squeeze casting method. To test for tribe a pin-on-disk machine and lubricant is used without paraffine 8.2CST at room temperature which is 40$\^{C}$. As the results of this study, the tribological properties of each specimen are more improved than AC4CH. The variation of coefficient resistance is more stable at the AC4CH and TiO$_2$, but the variation rates are higher at the inanimate binder.

GIS를 이용한 로스엔젤레스에 매설된 강관 손상 평가 (Loss Estimation of Steel Pipeline Damage in Los Angeles Using GIS)

  • Jeon, Sang-Soo
    • 한국지반공학회논문집
    • /
    • 제20권2호
    • /
    • pp.47-58
    • /
    • 2004
  • 강관은 Northridge 지진이 발생했을 당시 산사태가 일어나는 언덕이나 산악지역에 매설되어 있었다. 본 논문은 지리정보체계(GIS) 시스템에서 위치에 따라 강관을 서로 다른 유형별로 분류하고 정의하였다. 이 논문은 지반속도와 강관의 손상관계를 분석하고 Northridge 지진 시 발생한 산사태의 영향을 받았던 지역을 조사하였다. 하나의 주목할 만한 사실은 Northridge 지진 후 강관의 손상률이 다른 종류의 매설관, 특히 캐스트아이런(CI)보다 더 높았다는 것이다. Northridge 지진으로 인한 상대적으로 높은 강관의 손상률은 가장 큰 내부압력을 요하는 곳에서의 설치관례와 부식으로 인한 영향으로 해석될 수 있다.

국내 지중 케이블 고장현황 분석 (Failure Analysis of Underground Transmission Cable Systems)

  • 강연욱;조성배;곽방명;임헌의;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2377-2379
    • /
    • 1999
  • In order to analyze failure rates of underground transmission power cable systems in Korea, the survey has been performed for the failure cases of cables, joints, and terminations in CV, OF and POF cable systems which occurred from 1983 to 1998. During 16 years, the failure cases due to trips of the systems were 47 among the total 108 cases, These 47 cases could be divided into internal reasons(manufacture/installation, corrosion and degradation) of 16 cases and external reasons (external mechanical damages, lightning, fire. etc.) of 31 cases. For the 154 kV cable systems during 12 years from 1987 to 1998, total failure rate was 0.0057 [case/100C-km/year] and internal reason failure rate was 0.0020 [case/100C-km/Year], which is similar to those of foreign countries. Also, the many cases of internal reason failures occurred in the early stage after the operations due to incorrect installations. This implies that the installation process is very important and some diagnostic tests such as PD measurement are needed besides after laying test.

  • PDF

북동태평양지역의 방산충 생층서 및 고해양환경 연구 (Radiolarian Biostratigraphy and Paleoceanographic Study from the Northeast Equatorial Pacific)

  • 김기현;박정희
    • Ocean and Polar Research
    • /
    • 제21권2호
    • /
    • pp.127-136
    • /
    • 1999
  • Radiolarian assemblages from KODOS area were analyzed in order to understand the biostratigraphy and paleoceanography of deep-sea sediment from the Northeast Equatorial Pacific. The sediment core was divided into two or three units on the basis of the chemical and physical properties. In the upper sediment, mixtures of Quaternary and Tertiary radiolarians are found indicating active reworking processes. Dissolution of radiolarians seem to increase with depth. Radiolarians are seldom in Unit III presumably due to dissolution and corrosion. The middle part of unit I appears to correspond to Collosphaera invaginata Zone (0.21 Ma). Unit II belongs to Collosphaera tuberosa Zone. Based on the absence of Stylatractus universus, we estimate its age to be younger than 0.42 Ma. Based on our analyses of radiolarians in Unit I and II, we estimated the age of unit III as Tertiary, particularly from Oligocene to Miocene. There may to be hiatuses of more than 3 My from late Miocene to Pliocene, which probably resulted from erosion and dissolution by the Antarctic Bottom Water Sedimentation rates during Quaternary range from 0.15 to 0.50 mm/ky with significant variabilities among stations. Radiolarians in the study area were mostly warm-water species.

  • PDF