DOI QR코드

DOI QR Code

증기발생기 급수링 관통손상 원인 및 영향 고찰

Study on Cause and Effect of SG Feed Water Ring Through-Wall Hole

  • 투고 : 2015.06.12
  • 심사 : 2015.06.24
  • 발행 : 2015.06.30

초록

The function of Feed Water Ring is to provide the flow path from Feedwater Nozzle to inside of SG(steam generator). Significant amounts of general FAC on the outside of the Feed Water Ring are not likely due to the low flow velocities in this area. However, on the interior of the Feed Water Ring, there may be areas of local higher flow velocity which could lead to higher FAC rates. These may include the inlet tee from the Feedwater Nozzle into the Feed Water Ring, the areas where the Feed Water Ring changes diameter, and especially the entrance area to the J-Nozzles. In this paper, the results of root cause analysis of through-wall hole observed at domestic WH 51F SG Feed Water Ring and its effect on the integrity and performance of SG are described. And, the maintenance strategy for WH 51F SG Feed Water Ring and the monitoring strategy for Downcomer Feed Water Ring of CE System 80 SG are presented.

키워드

참고문헌

  1. EPRI, 2011, "Steam Generator Management Program: Investigation of Steam Generator Secondary-Side Degradation", TR-1022830
  2. J.S. Rees, T.J. Pournaras, D. Merkovsky, 2011, "Evaluation of Steam Generator Internals with Erosion Corrosion", Westinghouse Letter LTR-SGDA-11-169
  3. ASME B&PV Code, Code Case N-597-2, 2003, "Requirements for Analytical Evaluation of Pipe Wall Thinning"
  4. EPRI, 1996, "Flow Accelerated Corrosion in Power Plants", TR-106611-R1
  5. EPRI, 2006, "Recommendations for an Effective FAC Program", NSAC-202L-R3