• Title/Summary/Keyword: corrosion evaluation

Search Result 908, Processing Time 0.03 seconds

Electrochemical and surface investigations of copper corrosion in dilute oxychloride solution

  • Gha-Young Kim ;Junhyuk Jang;Jeong-Hyun Woo;Seok Yoon;Jin-Seop Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2742-2746
    • /
    • 2023
  • The corrosion behavior of copper immersed in dilute oxychloride solution (100 mM) was studied through surface investigation and in-situ monitoring of open-circuit potential. The copper corrosion was initiated with copper dissolution into a form of CuCl-2, resulting in mass decrease within the first 40 h of immersion. This was followed by a hydrolysis reaction initiated by the CuCl-2 at the copper surface, after which oxide products were formed and deposited on the surface, resulting in a mass increase. The formation of nucleation sites for copper oxide and its lateral extension during the corrosion process were examined using focused ion beam (FIB)-scanning electron microscopy (SEM). The presence of metastable compounds such as atacamite (CuCl2·3Cu(OH)2) on the corroded copper surface was revealed by X-ray photoelectron spectra (XPS) and transmission electron microscopy (TEM)-energy dispersive spectrometry (EDS) analysis.

Inspection of corrosion in under frame side sill for rolling stocks using pulsed eddy current testing (펄스 와전류(Pulsed eddy current)를 이용한 도시철도차량의 Under Frame Side Sill 부식 평가)

  • Kim, Woong-Ji;Song, Sung-Jin;Kim, Hak-Jun;Chung, Jung-Duk;Lee, Chan-Woo
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1117-1124
    • /
    • 2009
  • Under frame side sill of rolling stock structure is designed for preventing corrosion in order to meet mechanical requirements. However during long operation time more than 20 years, there are corrosion in the under frame side sill caused by environmental effect, vibration and etc. So, detection and evaluation of the corrosion ill the under frame nondestructive is one of important issues to extend their life time. Most of nondestructive methods are not easy to apply for detecting corrosion in the under frame side sill, since the under frame side sill consist of there layered with different material (stainless steel - stainless steel - mild steel) and each layer is connected by spot weld and plug weld. Fortunately, pulsed eddy current method claimed that it can be measured not only thickness change but also corrosion under their insulation layers. So, in this study, we have investigated performance of pulsed eddy current testing method by measuring thickness variation of fabricate of mock-up specimens. The investigation results obtained from mock-up specimens and the corrosion evaluation results of the aged rolling stocks will be presented.

  • PDF

Study on Evaluation of Strength Properties of RC Beams Damaged by Corrosion of Tension Main Rebar (인장주근이 부식한 RC보의 내력성능 평가에 관한 연구)

  • 이한승
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.665-670
    • /
    • 1998
  • This study was carried out to investigate quantitatively the relationship between the degree of rebar corrosion and the strength of reinforced concrete beams. After producing equations for the relationship between both the tensile properties of rebars and bond properties and the corrosion percentage of rebars. Finite element analysis and bending tests were conducted for RC beams damaged by corrosion of tension main rebar. As a result, it was made that the strength of RC beams damged by corrosion could be practically simulated by FEM using experimentally determined material representing the bond properties and the mechanical properties of corroded rebars.

  • PDF

Evaluation of Corrosion Protection for Epoxy and Urethane Coating by EIS under Various Cyclic Corrosion Tests

  • Hyun, Jonghun;Shon, Minyoung
    • Corrosion Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.95-100
    • /
    • 2011
  • Protective coatings play an important role in the protection of metallic structures against corrosive environment. The main function of anticorrosive coating is to prevent the materials from corrosive agents, such as water, oxygen and ions. In the study, the corrosion protection properties of urethane and epoxy coating systems were evaluated using EIS methods exposed to the corrosion acceleration test such as Norsok M501, Prohesion and hygrothermal cyclic test. AFM analysis of the coating systems was carried out to monitor the change of roughness of coatings. Urethane coating system was more stable than the epoxy coating under given cyclic conditions. Water uptake into the urethane coatings was less than that into the epoxy coating. The urethane coating system showed better corrosion protection than epoxy coating system based on the changes of the impedance modulus at low frequency region with exposure time. Consequently, the corrosion protection properties of the epoxy and urethane coatings was well correspond with their surface roughness changes and water uptakes.

Evaluation of Corrosion Fatigue Life of TMCP Steel Using the DCPD Method (DCPD 법을 이용한 TMCP 강의 부식피로수명 평가)

  • Park, Jin-Hyung;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.220-225
    • /
    • 2003
  • In order to develop a method of corrosion fatigue design and estimate reliability of TMCP steel using as the material of heavy industries and plants, its corrosion susceptibilities and corrosion fatigue life considering corrosion degradation were investigated. From the results, the corrosion characteristic of TMCP steel is very susceptible in 3.5wt.% NaCl solution. Its susceptibility was linearly increased with the solution temperature increase. The potential difference due to the crack growth behavior in $25^{\circ}C$, 3.5wt.% NaCl solution is very susceptible. And it was found that stress amplitude has a linear relationship with the critical potential. Therefore, it is expected that the corrosion fatigue life of TMCP steel can be nondestructively predicted using the DCPD method.

  • PDF

Prevention of Crevice Corrosion of STS 304 Stainless Steel by a Mg-alloy Galvanic Anode

  • Lim, U.J.;Yun, B.D.;Kim, J.J.
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.90-93
    • /
    • 2006
  • Prevention of crevice corrosion was studied for STS 304 stainless steel using a Mg-alloy galvanic anode in solutions with various specific resistivity. The crevice corrosion and corrosion protection characteristics of the steel was investigated by the electrochemical polarization and galvanic corrosion tests. Experimental results show that the crevice corrosion of STS 304 stainless steel does not occur in solutions of high specific resistivity, but it occurs in solutions of low specific resistivity like in solutions with resistivities of 30, 60 and $115{\Omega}{\cdot}m$. With decreasing specific resistivity of the solution, the electrode potential of STS 304 stainless steel in the crevice is lowered. The potential of STS 304 stainless steel in the crevice after coupling is cathodically polarized more by decreasing specific resistivity indicating that the crevice corrosion of STS 304 stainless steel is prevented by the Mg-alloy galvanic anode.

A Research on Stray-Current Corrosion Mechanism of High Voltage Cable Connector on Electrification Vehicles

  • Lee, Hwi Yong;Ahn, Seung Ho;Im, Hyun Taek
    • Corrosion Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.117-120
    • /
    • 2019
  • Considering the tendency of development of electrification vehicles, development and verification of new evaluation technology is needed because of new technology applications. Recently, as the battery package is set outdoors of an electric vehicle, such vehicles are exposed to corrosive environments. Among major components connected to the battery package, rust prevention of high-voltage cables and connectors is considered the most important issue. For example, if corrosion of high voltage cable connectors occurs, the corrosion durability assessment of using an electric vehicle will be different from general environmental corrosion phenomena. The purpose of this study is to investigate the corrosion mechanism of high voltage cable connectors of an electric vehicle under various driving environments (road surface vibration, corrosion environment, current conduction by stray current, etc.) and develop an optimal rust prevention solution. To improve our parts test method, we have proposed a realistic test method to reproduce actual electric vehicle corrosion issues based on the principle test.

Fatigue Strength Evaluation of Rusting Decayed Hull Steel Plate in Air and in Artificial Seawater Condition (선체의 부식쇠모강판의 대기중 및 해수중 피로강도평가에 관한 연구)

  • Kim, Won-Beom;Paik, Jeom-Kee;Iwata, Mitsumasa;Yajima, Hiroshi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.4 s.148
    • /
    • pp.467-475
    • /
    • 2006
  • Fatigue strength of hull structural steel plate, extracted from longitudinal bulkhead of a 17-year-old ore/oil carrier for renewal, was investigated in air and in artificial seawater condition. The surface of the plate was covered with corrosion pits and they proved to be crack initiation sites by fractography using SEM. From this research, it was found that the evaluation method for fatigue strength of virgin mild steel plates in air and in artificial seawater can also be applied to the evaluation of the fatigue strength of mild steel plates those were long-term exposed to a corrosive environment and their surfaces had been rusted intensively.

A Study on the Corrosion Properties of Reinforcing bar and Performance Evaluation of Repair Material and Method for Reinforced Concrete Structure by Exposure Experiment under the Coastal and Normal Atmosphere Environment (해양 및 일반대기환경의 폭로실험에 의한 철근콘크리트구조물 보수재료.공법의 성능평가 및 철근의 부식특성에 관한 연구)

  • Nam Jeong-Soo;Roh Kyung-Min;Shin Seung-Bong;Kim Young-Sun;kim Gyu-Yong;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.167-171
    • /
    • 2006
  • In this study, for the establishment of the performance evaluation methods of repair material and method for reinforced concrete structure and the quality control standards of durability recovery method, the quantitative exposure data by exposure experiment under the coastal and normal atmosphere environment is accumulated and analyzed. Investigating and evaluating the result of exposure experiment during 30 months of exposure age under the coastal and normal atmosphere environment, carbonation depth and chlorideion penetration depth very little penetrated than cover depth. It seems reasonable to conclude that main cause of corrosion of reinforcing bar are inner chloride-ion and macro cell from the result of corrosion area and corrosion velocity. Accordingly, it is considered that fundamental data on the performance evaluation and quality control standards of repair material and method could be presented through continuous exposure test in the future.

  • PDF