• Title/Summary/Keyword: correction methods

Search Result 2,007, Processing Time 0.031 seconds

Determination of Representative Renal Depth for Accurate Attenuation Correction in Measurement of Glomerular Filtration Rate in Transplanted Kidney (이식 신의 사구체 여과율 측정에서 정확한 감쇄 보정을 위한 신장 깊이 대표값 설정)

  • Oh, Soon-Nam;Kim, Sung-Hoon;Rha, Sung-Eun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2002
  • Purpose: To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. Materials and Methods: We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured GFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depths under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. Results: The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are $4.09{\pm}0.65cm$ in men, and $4.24{\pm}0.78cm$ in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. Conclusion: When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

Principal component analysis in C[11]-PIB imaging (주성분분석을 이용한 C[11]-PIB imaging 영상분석)

  • Kim, Nambeom;Shin, Gwi Soon;Ahn, Sung Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.12-16
    • /
    • 2015
  • Purpose Principal component analysis (PCA) is a method often used in the neuroimagre analysis as a multivariate analysis technique for describing the structure of high dimensional correlation as the structure of lower dimensional space. PCA is a statistical procedure that uses an orthogonal transformation to convert a set of observations of correlated variables into a set of values of linearly independent variables called principal components. In this study, in order to investigate the usefulness of PCA in the brain PET image analysis, we tried to analyze C[11]-PIB PET image as a representative case. Materials and Methods Nineteen subjects were included in this study (normal = 9, AD/MCI = 10). For C[11]-PIB, PET scan were acquired for 20 min starting 40 min after intravenous injection of 9.6 MBq/kg C[11]-PIB. All emission recordings were acquired with the Biograph 6 Hi-Rez (Siemens-CTI, Knoxville, TN) in three-dimensional acquisition mode. Transmission map for attenuation-correction was acquired using the CT emission scans (130 kVp, 240 mA). Standardized uptake values (SUVs) of C[11]-PIB calculated from PET/CT. In normal subjects, 3T MRI T1-weighted images were obtained to create a C[11]-PIB template. Spatial normalization and smoothing were conducted as a pre-processing for PCA using SPM8 and PCA was conducted using Matlab2012b. Results Through the PCA, we obtained linearly uncorrelated independent principal component images. Principal component images obtained through the PCA can simplify the variation of whole C[11]-PIB images into several principal components including the variation of neocortex and white matter and the variation of deep brain structure such as pons. Conclusion PCA is useful to analyze and extract the main pattern of C[11]-PIB image. PCA, as a method of multivariate analysis, might be useful for pattern recognition of neuroimages such as FDG-PET or fMRI as well as C[11]-PIB image.

  • PDF

Recent Changes in Bloom Dates of Robinia pseudoacacia and Bloom Date Predictions Using a Process-Based Model in South Korea (최근 12년간 아까시나무 만개일의 변화와 과정기반모형을 활용한 지역별 만개일 예측)

  • Kim, Sukyung;Kim, Tae Kyung;Yoon, Sukhee;Jang, Keunchang;Lim, Hyemin;Lee, Wi Young;Won, Myoungsoo;Lim, Jong-Hwan;Kim, Hyun Seok
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.3
    • /
    • pp.322-340
    • /
    • 2021
  • Due to climate change and its consequential spring temperature rise, flowering time of Robinia pseudoacacia has advanced and a simultaneous blooming phenomenon occurred in different regions in South Korea. These changes in flowering time became a major crisis in the domestic beekeeping industry and the demand for accurate prediction of flowering time for R. pseudoacacia is increasing. In this study, we developed and compared performance of four different models predicting flowering time of R. pseudoacacia for the entire country: a Single Model for the country (SM), Modified Single Model (MSM) using correction factors derived from SM, Group Model (GM) estimating parameters for each region, and Local Model (LM) estimating parameters for each site. To achieve this goal, the bloom date data observed at 26 points across the country for the past 12 years (2006-2017) and daily temperature data were used. As a result, bloom dates for the north central region, where spring temperature increase was more than two-fold higher than southern regions, have advanced and the differences compared with the southwest region decreased by 0.7098 days per year (p-value=0.0417). Model comparisons showed MSM and LM performed better than the other models, as shown by 24% and 15% lower RMSE than SM, respectively. Furthermore, validation with 16 additional sites for 4 years revealed co-krigging of LM showed better performance than expansion of MSM for the entire nation (RMSE: p-value=0.0118, Bias: p-value=0.0471). This study improved predictions of bloom dates for R. pseudoacacia and proposed methods for reliable expansion to the entire nation.

A Study on the Measurement of Dynamic Visual Acuity according to the Change of Accommodative Stimulus (조절자극 변화에 따른 동체시력(Dynamic visual acuity) 측정에 관한 연구)

  • Jin, Moon-Seog;Jeon, In-Chul
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate the difference in the dynamic visual acuity between (DVA) the distance and near and the effect of change of accommodative stimulus on the dynamic visual acuity by the addition of the plus lens. Methods : The study involved 40 male and female adults ($22.84{\pm}2.43$ years old) with over 1.0 of visual acuity and without systemic disease or ocular disease. We compared the distance and near DVA and the change of DVA induced by the addition of the plus lens(+0.50D, +1.00D, +1.50D). Results : The distance DVA and near DVA are $78.86{\pm}19.46deg/sec$ and $76.90{\pm}18.05deg/sec$ respectively. The distance DVA was slightly higher(p=0.04). The higher the distance DVA, the higher the positive correlation with the near DVA and distance DVA, and distance DVA was higher in those who had higher the near DVA(r=0.95, p=0.00, Fig. 4). The near DVA according to the change of accommodative stimulus was $75.95{\pm}18.85deg/sec$ in full correction and the near DVA with +0.50D spherical power was $76.95{\pm}16.45$ but there was no statistically significant differences(p>0.05). However, the near DVA with +1.00D spherical power was $79.02{\pm}13.51deg/sec$ and it was slightly higher. Also, the near DVA with +1.50D spherical power was $84.28{\pm}18.96deg/sec$, there and it was statistically significant difference(p<0.05). Conclusion : There is no difference between distance and near DVA, but near DVA is also excellent if distance DVA is good. The DVA increases as added a plus lens for controlled accommodative stimulation changes.

Differences in Urine Cadmium Associations with Renal Damage Markers According to the Adjustment with Specific Gravity or Urinary Creatinine (요비중 또는 크레아티닌 보정에 따른 요중 카드뮴과 신장손상지표와의 관련성 비교)

  • Kim, Yong-Dae;Eom, Sang-Yong;Yim, Dong-Hyuk;Kwon, Soon Kil;Park, Choong-Hee;Kim, Guen-Bae;Yu, Seung-Do;Choi, Byung-Sun;Park, Jung-Duck;Kim, Heon
    • Journal of Life Science
    • /
    • v.29 no.2
    • /
    • pp.265-271
    • /
    • 2019
  • In general, specific gravity (SG) and urinary creatinine (CR) have been used to adjust urinary cadmium (Cd) concentrations. However, the validity of correction methods has been controversial. We compared the two adjustments to evaluate associations between urinary Cd and various renal damage markers and to evaluate the relationship between urinary Cd concentration and renal disease markers, such as estimated glomerular filtration rate (eGFR), in a relatively large general population sample. Among the 1,086 volunteers who were enrolled in this study, 862 healthy volunteers who did not have kidney disease were included in the final analysis. Urinary Cd, malondialdehyde (MDA), and N-acetyl-${\beta}$-D-glucosaminidase (NAG) concentrations were measured, the creatinine-based eGFR was calculated, and the relationships between these markers were subsequently analyzed. This study showed the use of urinary Cd concentration adjusted with SG rather than with urinary creatinine may be appropriate in studies evaluating renal function based on Cd exposure. Urinary Cd concentration adjusted with SG had a positive correlation with urinary MDA levels and a negative correlation with eGFR. This relationship was relatively stronger in women than in men. This study showed that urinary Cd level was associated with decreased eGFR in the general population, and oxidative stress was likely to act as an intermediator in this process. These results suggest that eGFR can be a very good indicator of kidney damage caused by Cd exposure in the general population.

Is It Appropriate to Insert Pedicle Screws at an Infected Vertebral Body in the Treatment of Lumbar Pyogenic Spondylodiscitis? (요추부 화농성 척추염의 수술적 치료: 이환된 추체에 척추경 나사 고정이 타당한가?)

  • Na, Hwa-Yeop;Jung, Yu-Hun;Lee, Joo-Young;Kim, Hyung-Do
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.419-426
    • /
    • 2021
  • Purpose: In the surgical treatment of pyogenic lumbar spondylodiscitis, screw insertion at the affected vertebra has been avoided because of biofilm formation, and the risk of infection recurrence. The authors analyzed the success rate of infection treatment while minimizing the number of instrumented segments by inserting pedicle screws into the affected vertebrae. Therefore, this study examined the usefulness of this technique. Materials and Methods: From January 2000 to June 2018, among patients with pyogenic lumbar spondylodiscitis treated surgically, group A consisted of patients with pedicle screws inserted directly at the affected vertebrae (28 cases), and group B underwent fusion by inserting screws at the adjacent normal vertebrae due to bone destruction of the affected vertebral pedicle (20 cases). The classified clinical results were analyzed retrospectively. All patients were treated via the posterior-only approach, so the affected disc and sequestrum were removed. Posterior interbody fusion was performed with an autogenous strut bone graft, and the segments were then stabilized with pedicle screw systems. The hospitalization period, operation time, amount of blood loss, EQ-5D index, duration of intravenous antibiotics, and the clinical and radiological results were analyzed. Results: In group A, the number of instrumented segments, operation time, blood loss, and EQ-5D index at one month postoperatively showed significant improvement compared to group B. There were no significant differences in the duration of antibiotic use, hospitalization, radiological bone union time, sagittal angle correction rate, and recurrence rate. Conclusion: Minimal segmental fixation, in which pedicle screws were inserted directly into the affected vertebrae through the posterior approach, reduced the surgery time and blood loss, preserved the lumbar motion by minimizing fixed segments and showed rapid recovery without spreading or recurrence of infection. Therefore, this procedure recommended for the surgical treatment of lumbar pyogenic spondyodiscitis.

Long-Term Results of Surgical Treatment for the Idiopathic Clubfoot (선천성 만곡족의 장기 수술적 치료 결과)

  • Kim, Hui Taek;Kim, In Hee;Cho, Yoon Je;Ahn, Tae Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.547-556
    • /
    • 2019
  • Purpose: This study evaluated the results of surgical treatment for residual or recurrent deformity after the conservative treatment of idiopathic clubfoot. Materials and Methods: Fifty-one cases (32 patients), who were followed up to skeletal maturity, were reviewed retrospectively. The mean age at the last follow-up was 18.7 years. The surgical options included selective or comprehensive soft tissue release, tendon lengthening and transfer, and various types of osteotomy. The radiology measurements included the talocalcaneal angle and talo-first metatarsal angle in the anteroposterior (AP) view, and the talocalcaneal angle and calcaneal pitch in the lateral view. The radiology measurements were compared with the normal values for adults. The clinical evaluations were made using the ankle-hindfoot score and the midfoot score of the American Orthopaedic Foot and Ankle Society (AOFAS): excellent (>85), good (71-85), pair (56-70), and poor (<56). Results: At the last follow-up, the percentages of the 51 cases, whose parameter values fell within the normal ranges were as follows: in the AP view, 41.2% (talocalcaneal angle); and 90.2% (talo-first metatarsal angle). In the lateral view, the percentage was 84.3% (talocalcaneal angle). For the calcaneal pitch, the percentages were 61%. The mean AOFAS score was 88.1±10.7 on the ankle-hindfoot score and 86.7±11.5 on the midfoot score. Conclusion: The long-term outcome of patients with idiopathic clubfoot, who underwent surgical treatment after conservative treatment, was found to be 43%-90% of the normal range of radiographic indices. Clinically, the mean AOFAS scores were "excellent". Therefore, a satisfactory result can be obtained by analyzing the elements of deformity more accurately and then using the selective operation method, even if the non-surgical correction method fails.

Surgical Treatment of Osteoporotic Vertebral Compression Fractures at Thoraco-Lumbar Levels: Only Pedicle Screw Constructs with Polymethylmethacrylate Augmentation (흉요추부 골다공증성 척추 압박 골절의 수술적 치료: 골시멘트 보강술을 이용한 척추경 나사 고정)

  • Jun, Deuk Soo;Baik, Jong-Min;Park, Ji Hyeon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.327-335
    • /
    • 2019
  • Purpose: To investigate the radiological efficacy of polymethylmethacrylate (PMMA) augmentation of pedicle screw operation in osteoporotic vertebral compression fractures (OVCF) patients. Materials and Methods: Twenty OVCF patients, who underwent only posterior fusion using pedicle screws with PMMA augmentation, were included in the study. The mean follow-up period was 15.6 months. The demographic data, bone mineral density (BMD), fusion segments, number of pedicle screws, and amount of PMMA were reviewed as medical records. To analyze the radiological outcomes, the radiologic parameters were measured as the time serial follow-up (preoperation, immediately postoperation, postoperation 6 weeks, 3, 6 months, and 1 year follow-up). Results: A total of 20 patients were examined (16 females [80.0%]; mean age, 69.1±8.9 years). The average BMD was -2.5±0.9 g/cm2. The average cement volume per vertebral body was 6.3 ml. The mean preoperative Cobb angle of focal kyphosis was 32.7°±7.0° and was improved significantly to 8.7°±6.9° postoperatively (p<0.001), with maintenance of the correction at the serial follow-up, postoperatively. The Cobb angle of instrumented kyphosis, wedge angle, and sagittal index showed similar patterns. In addition, the anterior part of fractured vertebral body height averaged 11.0±5.0 mm and was improved to 18.5±5.7 mm postoperatively (p=0.006), with maintenance of the improvement at the 3-month, 6-month, and 1-year follow-up. Conclusion: The reinforcement of pedicle screws using PMMA augmentation may be a feasible surgical technique for OVCF. Moreover, it appears to be appropriate for improving the focal thoracolumbar/lumbar kyphosis and is maintained well after surgery.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.