• Title/Summary/Keyword: corner effect

Search Result 317, Processing Time 0.029 seconds

A study on the improvement of cutting precision of CNC system using $H_{\infty}$ 2-degree-of-freedom controller ($H_{\infty}$ 2 자유도 제어기를 이용한 CNC 시스템의 가공 정밀도 향상에 관한 연구)

  • 최성규;최병욱;현용탁;강성귀;권욱현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1040-1043
    • /
    • 1996
  • The accuracy of the servo control in CNC system has a great influence on the duality of machine product. Tracking performance of the servo control is deteriorated mainly by the time delay of the servo system and the inertia of the work table or bed. Contouring errors occur in every interpolation steps by the effect of the tracking performance. In this paper, $H_{\infty}$ two-degree-of-freedom(TDF) controller is designed for improvement to improve the tracking performance. The designed controller is applied 3-axis machining center model and the cutting accuracy is simulated in case of corner cutting, circular and involute interpolation. Simulation results show that $H_{\infty}$ TDF controller designed in this paper has a good effect to improve tracking performance in CNC system.

  • PDF

Feature Based Map Building Method Using Sonar Data

  • Soo, Kang-Byung;Hwan, Lim-Jong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.134.1-134
    • /
    • 2001
  • The paper presents a sonar based map building method. The environment is a room or area inside a building, which is composed of four types of geometric primitives(corners, edges, cylinders, and walls). We also assume the environment can be modeled into two dimensional map in terms of planes(walls), points(corner and edge), and circle(cylinder). In a real world where most of the object surfaces are specular ones, a sonar sensor suffers from a multipath effect which results in a wrong interpretation of the location of an object. To reduce the effect and uncertainty, the method employs a simple thresholding technique for extracting circular arc features called regions of constant depth(RCD) from scanning sonar data. The usefulness of the approach is illustrated with the results produced by sets of experiments.

  • PDF

A Numerical Study on the Planar Contraction Flow of Oldroyd B Fluids (Oldroyd B 유체의 평면 수축 유동에 관한 수치 해석적 연구)

  • Yoo, Jung-Yul;Na, Yang
    • The Korean Journal of Rheology
    • /
    • v.2 no.1
    • /
    • pp.33-45
    • /
    • 1990
  • This study analyzes the planar 4:1 contraction flow of viscoelastic fluids with retardation time using finite volume method. To consider separately the elasticity effect of the viscoelastic fluid without shear thinn-ing effect, Oldroyd B liquid model is adopted for the numerical simulation. Instead of the stream function-vorticity formulation, SIMPLER algorithm with staggered grid system which incorporates primitive variable has been introduced in discretizing the momentum equations. An upwind corrected scheme has been used in discetizing the constitutive equations for the non-Newtonian part of the stress. The size of the corner vortex is shown to be slightly influenced by the Weissenberg number. However as the Weissenberg number is increased the chang-ing of the vortex shape agrees qualitatively well with some experimental studies.

  • PDF

Numerical Analysis of the Chill Effect in L-shaped Sand Castings (L-형 사형주조에서 Chill 효과에 관한 수치적 해석)

  • Kim, Sam-Dong;Kang, Choon-Sik
    • Journal of Korea Foundry Society
    • /
    • v.5 no.2
    • /
    • pp.109-117
    • /
    • 1985
  • A two dimensional analysis of the solidification phenomena has been simulated by IAD (Implicit Alternating Direction)method for L-shaped castings with external chills. The effect of chills has been studied with the variation of chill size, shape, and their materials, and also with the variation of the pouring temperature. Three kinds of cross-sectional shapes of chills such as triangle, square, and L-shape were chosen, and graphite, cast iron, and copper for their materials. It has been shown by the computation that the hot spot at the junction of L-shaped castings can not be removed by external chills, and that the distance between the inner corner and the hot spot on the line of symmetry, as well as the solidification time of castings depend only on VHC (Volumetric Heat Capacity).

  • PDF

Beam and shadow effects occurring at connetions of tubes in the molecular flow (분자류에서 도관의 연결부에 나타나는 빔 효과와 그림자 효과)

  • 인상렬
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • An unexpected error is produced in calculating the transmission probability of a multipartite duct because of beam and shadow effects, if using a simple summation rule like the Oatley's equation. Particles moving in a tube are directed more or less towards the axis of the tube by the beam effect, and the length of a compound tube shortens virtually by the shadow effect originated from a reduction in the number of particles reaching the corner between two tubes of different cross-sections. Both effects make the transmission probability of the tube connected behind and consequently of the whole duct increase slightly. In this paper sources of the error in the calculation of the transmission probability are analyzed quantitatively and variations in the error depending on the dimensions of cylindrical tubes are calculated.

  • PDF

Bi-layer channel large grain TFT의 channel width의 변화에 따른 전기적 특성 비교 분석

  • Lee, Won-Baek;Park, Hyeong-Sik;Park, Seung-Man;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.430-430
    • /
    • 2010
  • MICC 방법으로 제작된 TFT는 large grain과 그에 따른 grain boundary의 감소로 인하여여, 소자의 전기적 특성을 좋게 할 수 있다. 본 연구에서는 bi-layer channel의 large grain size TFT를 제작하여 소자의 전기적 특성을 비교하였다. Channel의 width / length의 크기는 각 각의 경우 $7/5{\times}2$, $10/5{\times}2$, $15/5{\times}2$ (${\mu}m$)로 하였다. 소자의 성능 측정 결과 Field-effect mobility의 경우에는 channel width가 증가할 수록 감소하는 경향성을 나타내었으며, Threshold voltage의 경우에는 조금 감소하는 경향성은 있었으나 변화의 폭이 매우 작았다. Output characteristics 의 경우에는 모든 set에서 좋은 saturation 특성을 보였다. 이것은 current croding이 없었다는 것을 의미하는데, 큰 grain size로 인한 효과로 해석 할 수 있다. 본 연구에서는 bi-layer channel에서 corner effect에 중점을 두어 소자의 전기적 특성 변화에 대하여 논하였다.

  • PDF

Combined effect of the horizontal components of earthquakes for moment resisting steel frames

  • Reyes-Salazar, Alfredo;Juarez-Duarte, Jose A.;Lopez-Barraza, Arturo;Velazquez-Dimas, Juan I.
    • Steel and Composite Structures
    • /
    • v.4 no.3
    • /
    • pp.189-209
    • /
    • 2004
  • The commonly used seismic design procedures to evaluate the maximum effect of both horizontal components of earthquakes, namely, the Square Root of the Sum of the Squares (SRSS) and the 30-percent (30%) combination rules, are re-evaluated. The maximum seismic responses of four three-dimensional moment resisting steel frames, in terms of the total base shear and the axial loads at interior, lateral and corner columns, are estimated as realistically as possible by simultaneously applying both horizontal components. Then, the abovementioned combination rules and others are evaluated. The numerical study indicates that both, the SRSS rule and the 30% combination method, may underestimate the combined effect. It is observed that the underestimation is more for the SRSS than for the 30% rule. In addition, the underestimation is more for inelastic analysis than for elastic analysis. The underestimation cannot be correlated with the height of the frames or the predominant period of the earthquakes. A basic probabilistic study is performed in order to estimate the accuracy of the 30% rule in the evaluation of the combined effect. Based on the results obtained in this study, it is concluded that the design requirements for the combined effect of the horizontal components, as outlined in some code-specified seismic design procedures, need to be modified. New combination ways are suggested.

Interference effects in a group of tall buildings closely arranged in an L- or T-shaped pattern

  • Zhao, J.G.;Lam, K.M.
    • Wind and Structures
    • /
    • v.11 no.1
    • /
    • pp.1-18
    • /
    • 2008
  • Interference effects in five square tall buildings arranged in an L- or T-shaped pattern are investigated in the wind tunnel. Mean and fluctuating shear forces, overturning moments and torsional moment are measured on each building with a force balance mounted at its base. Results are obtained at two values of clear separation between adjacent buildings, at half and a quarter building breadth. It is found that strong interference effect exists on all member buildings, resulting in significant modifications of wind loads as compared with the isolated single building case. Sheltering effect is observed on wind loads acting along the direction of an arm of the "L" or "T" on the inner buildings. However, increase in these wind loads from the isolated single building case is found on the most upwind edge building in the arm when wind blows at a slight oblique angle to the arm. The corner formed by two arms of buildings results in some wind catchment effect leading to increased wind pressure on windward building faces. Interesting interference phenomena such as negative drag force are reported. Interference effects on wind load fluctuations, load spectra and dynamic building responses are also studied and discussed.

Analysis of the GPS-derived Control Point Errors for Quality Assurance of 3D Digital Maps (3차원 수치지도 정확도 검증을 위한 GPS 기반 기준점 오차의 영향 분석)

  • Bae, Tae-Suk;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.153-160
    • /
    • 2010
  • It is necessary to determine accurate 3-dimensional coordinates of the building corner points that could be control or check points in order to verify the accuracy of 3D digital maps in the near future. The usual process of obtaining the coordinates of the building corner points is to set up the ground control points with a GPS and then to practice terrestrial survey such as distance or angle measurements. However, since an error in the ground control points can be propagated through the terrestrial survey into the final coordinates of the buildings, accurately should be considered as much as possible. The actual effect of the GPS-derived ground control point error on the estimates of the unknowns through the terrestrial survey is mathematically analyzed, and the simulation data is tested numerically. The error of the ground control points is tested in the cases of 1-4 cm for the horizontal components and 2-8 cm for the vertical component. The vertical component error is assigned twice the horizontal ones because of the characteristics of the GPS survey. The distance measurement is assumed for convenience and the precision of the estimated coordinates of the building corner points is almost linearly increased according to the errors of the ground control points. In addition, the final estimates themselves can vary by the simulated random errors depending on the precision of the survey instrument, but the precision of the estimates is almost independent of survey accuracy.

Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns with Loading (섬유혼입공법을 적용한 고강도콘크리트 기둥의 재하 내화시험)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Kim, Heung-Youl
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.473-480
    • /
    • 2009
  • The 180 minutes fire test based on the standard curve of ISO-834 were conducted on three RC column specimens with different constant axial loading ratios to evaluate the fire performance of fiber cocktail (polypropylene+steel fiber) reinforced high strength concrete column. The columns were tested under three loading levels as 40%, 50%, and 61% of the design load. No explosive spalling has been observed and the original color of specimen surface has been changed to light pinkish grey. The maximum axial displacements of three specimens were 1.5~2.2 mm. There was no reduction in load bearing capacity of each specimen exposed to fire and no effect were observed on the fire performance within 61% of the design load. The tendencies of the results with loading, such as the temperature distribution of in concrete and the changes in temperature rise due to the water vaporization in concrete, are very similar to those without loading. The final temperatures of steel rebar after 180 minutes of fire test resulted in 491.4${^{\circ}C}$ for corner rebar, 329.0${^{\circ}C}$ for center rebar, and 409.8${^{\circ}C}$ for total mean of steel rebar. The difference of mean temperature between corner and center rebar was 153.7${^{\circ}C}$ㅍ. The tendency of temperature rise in concrete and steel rebar changed after 30~50 minutes from the starting time of the fire test because the heat energy influx into corner rebar is larger than that into center rebar. The cause of decrease in temperature rise was due to the water vaporization in concrete, the lower temperature gradient of the concrete with steel and polypropylene fiber cocktails, the moisture movement toward steel rebars and the moisture clogging.