• Title/Summary/Keyword: core power distribution

Search Result 295, Processing Time 0.029 seconds

Implementation of S1n91e-Phase SAMRT Meter using Programmable IC (Programmable IC를 이용한 다기능 전자식 단상 전력량계 기능 구현)

  • Park, Jong-Beom;Yoon, Gi-Gab;Woo, Sang-Mok;Park, In-Kwon;Kim, Hong;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.644-646
    • /
    • 2000
  • According to the deregulations of governments in the world. the power industries of United State and European nations are proceeding remote meter reading and remote load control. But the core technology of multifunctional electronic meter implemented by programmable one-chip IC, which can be the right answer of all the power industy's efforts is now still under development in the advanced countries. Implementation of smallest size, lowest price single-phase meter with features which enable distribution automation such as bidirectional communication, Remote load control, remote meter reading, remote credit assigment. Prepayment billing system.

  • PDF

Electrical Characteristics of Super Junction MOSFET According to Trench Etch Angle of P-pillar (P-pillar 식각 각도에 따른 Super Junction MOSFET의 전기적 특성 분석에 관한 연구)

  • Kang, Ey Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.8
    • /
    • pp.497-500
    • /
    • 2014
  • In this paper, we analyze electrical characteristics of n/p-pillar layer according to trench angle which is the most important characteristics of SJ MOSFET and core process. Because research target is 600 V class SJ MOSFET, so conclusively trench angle deduced 89.5 degree to implement the breakdown voltage 750 V with 30% margin rate. we found that on resistance is $22mohm{\cdot}cm^2$ and threshold voltage is 3.5 V. Moreover, depletion layer of electric field distribution also uniformly distributes.

Implementation of Three-Phase SAMRT Meter using Programmable IC (Programmable IC를 이용한 다기능 전자식 삼상 전력량계 기능 구현)

  • Park, Jong-Beom;An, Yong-Ho;Kim, Hong;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2039-2041
    • /
    • 2001
  • According to the deregulation of governments in the world, the power industries of United State and European nations are proceeding remote meter reading and remote load control. But the core technology of multifunctional electronic meter implemented by programmable one-chip IC, which can be the right answer of ail the power industy's efforts is now still under development in the advanced countries. Implementation of smallest size, lowest price three-phase meter with features which enable distribution automation such as bidirectional communication. The three phase metering IC and meter can be used as metering, automatic meter reading and transformer monitoring. Prepayment billing system.

  • PDF

The study on the DC Ic measurement and AC loss in the 22.9kV, 50MVA HTS power cable (22.9kV/50MVA급 고온초전도 전력케이블의 DC Ic 측정 및 교류손실에 관한 연구)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.808-809
    • /
    • 2008
  • 22.9kV 50MVA HTS power cable has been developed and tested by Korea Electrotechnology Research Institute and LS Cable Company and it was supported by a grant from Center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program. In this paper, DC Ic of 100m HTS cable which is installed at Kochang testing station was measured and analyzed. A measurement technique of DC Ic used by resistance and inductance removal method is established. The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. For the analysis of AC losses in an HTS power cable, 2-dimensional numerical calculation was carried out to define the magnetic field distribution. We calculated the magnetization losses in the HTS core of that cable from these fields. These calculated results are in accordance with those of experiment.

  • PDF

A Study on the Reliability Prediction and Lifetime of the Electrolytic Condenser for EMU Inverter (전동차 인버터 구동용 전해콘덴서의 신뢰도예측과 수명 연구)

  • Han, Jae-Hyun;Bae, Chang-Han;Koo, Jeong-Seo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Inverter module, which feeds the converted power to the traction motor for EMU. Consists of the power semiconductors with their gate drive unit(GDU)s and the control computer for driving, voltage, current and speed controls. Electrolytic condenser, connected to the gate drive unit and a core component to drive the power semiconductor, has problems such as reduction in lifetime and malfunction caused by electrical and mechanical characteristic changes from heat generation during high speed switching for generation of stable power. In this study, To check the service life of electrolytic condenser, the test was carried out in two ways. First, In the case of accelerated life testing of condenser, the Arrhenius model is a way of life testing. Another way is to analyze the reliability of the failure data by the method of parametric data analysis. Eventually, life time by accelerated life test than a method of failure data analysis(Weibull distribution) was found to be slightly larger output.

The Study on the Current Limiting Characteristics of YBCO Coated Conductor with Different kinds of Stabilization Layer Applied to SFCL Using Iron Core and Coil (철심과 권선을 이용한 전류제한기에 적용시킨 안정화층이 다른 YBCO Coated Conductor의 전류제한 특성에 관한 연구)

  • Lee, Dong-Heok;Du, Ho-Ik;Kim, Yong-Jin;Han, Byoung-Sung;Yim, Seong-Woo;Han, Sang-Chul;Lee, Jeong-Phil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.788-792
    • /
    • 2010
  • The yttrium-barium-copper-oxide (YBCO) coated conductor, which supplement the fault of the existing superconducting current-limit materials YBCO thin film, bismuth-strontium-calcium-copper-oxide(BSCCO) wire and bulk, has been improved its mechanical weakness and has high index; hence, after quench YBCO coated conductor could limit the fault current effectively because of fast resistance occurrence speed. Furthermore, it has wide applicable area as an current limit material because it shows different resistance occurrence tendency by the thickness and kind of stabilization material sputtered on the superconducting layer. Therefore, many researchers are carrying out the study of application of YBCO coated conductor to superconducting fault current limiter (SFCL) for making high quality current limit element, based on resistance type. On the other hand, the study for other type except resistance type has been rarely conducted for the application of YBCO coated conductor to SFCL as an current limit element. Consequently, in this study, YBCO coated conductor with different stabilization layer Cu and Stainless steel, is applied to SFCL using iron core and coil, and examine the many index points as an current limit element, such as current limit characteristic, the tendency of resistance occurrence, response time, the temperature trend for stability.

Fabrication of 13Cr-1.5Nb-Fe Alloy Powder and AC Magnetic Properties of the Sintered Magnetic Core (소결 13Cr-1.5Nb-Fe 합금의 교류 자기 특성)

  • 오환수;김택기;조용수
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.11-15
    • /
    • 2000
  • 13Cr-1.5Nb-Fe alloy powder prepared by water atomizing method is reduced with flowing hydrogen gas. The characteristics of a reduced alloy powder is investigated and magnetic cores formed by using the reduction power sintered in the vacuum of ∼10$\^$-5/ Torr. In order to study on the magnetic cores permeability and power loss in alternating magnetic field are also measured. The result of particle size distribution shows the paticle size is 70 ㎛ at volume fraction of 50 %. The saturation magnetization of the reduced alloy powder is 160 emu/g. The relative peak permeability (H$\_$a/=5Oe) of a magnetic core is 400 and the power loss (B$\_$m/=80G) 0.12 mW/cc at sintering temperature of 1,200 $\^{C}$, 10 ton/㎠ forming pressure, and 1 kHz.

  • PDF

A Three-Dimensional Simulation of Kori-1 Core by Nodal Method

  • Kim, Young-Jin;Moon, Kap-Suk;Lee, Sang-Keun;Lee, Ji-Bok;Lee, Chang-Kun
    • Nuclear Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 1981
  • The KINS (KAERI-Improved Nodal Simulation) program, a three-dimensional nodal simulation code for pressurized water reactors, has been developed and benchmarked against the first cycle of the Kori-1 reactor. The KINS program is based on the computational model used in FLARE code and has been modified to represent the PWR characteristics more explicitly. The critical boron concentration and three-dimensional power distribution at the beginning of life hot zero power have been calculated and compared with the operating data. A three-dimensional depletion calculation at the intervals of 1000 MWD/MTU turnup steps has been performed. As the result of comparison, our calculation is shown to be in excellent agreement with the operating data. It is displayed that, incorporated with the computing time, the KINS program is an effective and powerful tool for PWR core management.

  • PDF

Analysis of Distributed Computational Loads in Large-scale AC/DC Power System using Real-Time EMT Simulation (대규모 AC/DC 전력 시스템 실시간 EMP 시뮬레이션의 부하 분산 연구)

  • In Kwon, Park;Yi, Zhong Hu;Yi, Zhang;Hyun Keun, Ku;Yong Han, Kwon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.159-179
    • /
    • 2022
  • Often a network becomes complex, and multiple entities would get in charge of managing part of the whole network. An example is a utility grid. While the entire grid would go under a single utility company's responsibility, the network is often split into multiple subsections. Subsequently, each subsection would be given as the responsibility area to the corresponding sub-organization in the utility company. The issue of how to make subsystems of adequate size and minimum number of interconnections between subsystems becomes more critical, especially in real-time simulations. Because the computation capability limit of a single computation unit, regardless of whether it is a high-speed conventional CPU core or an FPGA computational engine, it comes with a maximum limit that can be completed within a given amount of execution time. The issue becomes worsened in real time simulation, in which the computation needs to be in precise synchronization with the real-world clock. When the subject of the computation allows for a longer execution time, i.e., a larger time step size, a larger portion of the network can be put on a computation unit. This translates into a larger margin of the difference between the worst and the best. In other words, even though the worst (or the largest) computational burden is orders of magnitude larger than the best (or the smallest) computational burden, all the necessary computation can still be completed within the given amount of time. However, the requirement of real-time makes the margin much smaller. In other words, the difference between the worst and the best should be as small as possible in order to ensure the even distribution of the computational load. Besides, data exchange/communication is essential in parallel computation, affecting the overall performance. However, the exchange of data takes time. Therefore, the corresponding consideration needs to be with the computational load distribution among multiple calculation units. If it turns out in a satisfactory way, such distribution will raise the possibility of completing the necessary computation in a given amount of time, which might come down in the level of microsecond order. This paper presents an effective way to split a given electrical network, according to multiple criteria, for the purpose of distributing the entire computational load into a set of even (or close to even) sized computational loads. Based on the proposed system splitting method, heavy computation burdens of large-scale electrical networks can be distributed to multiple calculation units, such as an RTDS real time simulator, achieving either more efficient usage of the calculation units, a reduction of the necessary size of the simulation time step, or both.

Evaluation of Neutron Flux Distributions of SMART-P IST Region for the Design of Ex-Core Detector (SMART 연구로 노외계측기 설계를 위한 IST 영역의 중성자속 분포 평가)

  • Koo, Bon-Seung;Kim, Kyo-Youn;Lee, Chung-Chan;Zee, Sung-Quun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2005
  • The evaluation of neutron flux distribution was performed for the ex-core detector design of SMART-P. DORT and MCNP code were used for the calculation of energy-dependent neutron flux distribution at 100% full power condition. Two code results show that maximum thermal flux appears at the $1^{st}$ water region in IST region and agree within 10% difference. In addition, another evaluation was performed code with assumptions that cote was composed of fission source and control rod without fuel assemblies. These assumptions make neutron count rate to be minimized. As a results, maximum thermal flux showed $6.99{\times}10^{-2}(n/cm^2-sec)$, when the strength of initial fission source was assumed as $1.0{\times}10^8(n/sec)$. The main reason of these results is due to the thermalization of fast neutrons in the water region and thermal flux is proportional to 80% of total neutron flux. Therefore, optimization of filler material of detector guide tube, position of installation and axial length of detector segments is necessary for the design of ex-core detector to enhance the neutron count rate and above results could be used in ex-core detector design as a fluence requirement.