• Title/Summary/Keyword: cop

Search Result 1,228, Processing Time 0.027 seconds

Experimental Study on the Coefficient of Performance of a Small Absorption Refrigerator (소형 흡수식 냉동기의 성적계수에 관한 실험적 연구)

  • Lee Sun Kyoo;Kim Sang Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.2
    • /
    • pp.176-184
    • /
    • 1987
  • The purpose of this research is to study the characteristics of the coefficient of perform-ance (COP) of the small absorption refrigeration system. This experimental study is performed with two selected variables, the temperature of the generator and the input temperature of the cooling water. In order to determine the input temperature of the generator which gives maximum COP, the experimental data are obtained with controlling the temperature of the generator in the range of $20-32^{\circ}C$ of the temperature of the cooling water. The range of the generator heat suppling temperature which gives maximum efficiency is about $90-95^{\circ}C.$ The temperature range depends on the characteristics of the equipment unit. The most important result in this experiment is the trends of the COP in accordance with the variation of these temperatures. This trend will furnish the informations and knowledges for designing and operating the absorption refrigerator.

  • PDF

Thermal Design Analysis of an Absorption Heat Transformer for using Waste Hot Water (폐온수 이용 제 2 종 흡수식 열펌프의 열역학적 설계해석)

  • Kang, Byung-Ha;Kim, Young-In;Lee, Chun-Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.4
    • /
    • pp.285-292
    • /
    • 1985
  • A computer program for thermal design analysis has been developed to predict the performance of an absorption heat transformer. The effects of temperature boost, cooling water temperature and effectiveness of components on the performance were investigated. Not only the detailed thermodynamic states such as temperatures, concentration of the solution, and mass flow rate at each point of the process but also the heat transfer rate in each component could be easily determined with given input parameters. The system's coefficient of performance (COP) was seen to increase with increased effectiveness of components, decreased temperature boost of hot water, and decreased cooling water temperature. Even though the COP increases with increased effectiveness of the components, the variation in the COP is not substantial above certain values of the effectiveness. A reference design point can be selected on this basis.

  • PDF

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.

Comparison of Plantar Foot Pressure and Shift of COP among Level walking, Stairs and Slope Climbing (평지 보행 그리고 계단과 경사로 오르기 동안 압력중심 이동경로 및 족저압 비교)

  • Han, Jin-Tae;Kim, Kyoung;Lim, Seung-Geon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.59-65
    • /
    • 2008
  • The purpose of this study was to investigate the shift of COP pathway and the plantar foot pressure among level walking and stairs and ramp climbing in young and elderly people. Plantar foot pressure was measured by MatScan system(Tekscan, USA). Statistical analysis was used One-way ANOVA to know the characteristics of peak plantar pressure during walking with different the facilities. In young adults, COP pathway during stairs climbing was slightly shorten and trended to abduct at forefoot. COP pathway during ramp climbing was also shorten but trend to adduct at forefoot. Peak plantar pressure of 2-3 metatarsal head and heel during ramp climbing was more decreased than level walking. In elderly people, COP pathway during stairs climbing was more shorten and abducted than leve walking and COP pathway during ramp climbing was more unstable than level walking. Peak plantar pressure of first metatarsal head increased at stair climbing and decreased at ramp climbing. That of second metatarsal head and heel was more decreased at ramp climbing. Conclusionally, Peak plantar pressures of each foot region generally increased and more changed during ramp climbing.

2008 National Survey of Idiopathic Interstitial Pneumonia in Korea (2008년도 특발성 간질성 폐렴(IIP) 전국실태조사보고)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.2
    • /
    • pp.141-151
    • /
    • 2009
  • Background: There is limited data on the epidemiology and relative frequency of idiopathic interstitial pneumonia (IIP) worldwide. This survey was performed to assess the epidemiology and relative frequency of IIP in Korea. Methods: The patients with IIP and who were confirmed by lung biopsy, except those patients with idiopathic pulmonary fibrosis, (IPF) over a 5 year period (from Jan. $1^{st}$, 2003 to Dec. $31^{st}$, 2007) were registered by a web-base questionnaire. Results: A total of 3,156 cases were registered, but 970 cases were excluded due to duplicative registration, inadequate data and the unmet ATS/ERS diagnostic criteria. A total of 2,186 cases were analyzed. The male to female ratio was about 2 : 1 and their mean age was 65 (range: 11-94). The most frequent disease was IPF (77.1%), followed in decreasing order by nonspecific interstitial pneumonia (NSIP) (11.9%), cryptogenic organizing pneumonia (COP) (8.5%), acute interstitial pneumonia (AIP) (1.1%), desquamative interstitial pneumonia (DIP) (0.9%), respiratory bronchiolitis-interstitial lung disease (RB-ILD) (0.4%) and lymphocytic interstitial pneumonia (LIP) (0.1%). The mean age of the patients with IPF, NSIP and COP was 67.8, 57.1 and 57.7 years old, respectively. The most frequent symptom was dyspnea on exertion (69%) followed by coughing (61%) and sputum (33%) for the whole population. The three year survival rate was 62% for the patients with IPF and the five year survival rate was 85% in both the NSIP and COP patients. Conclusion: This survey provides helpful information for the management of IIP and to produce management guidelines for this illness in Korea.

Postural Control in Brain Damage Patients According to Moving Surround (뇌기능 장애 환자의 가상영상(Moving Sorround) 자극에 따른 자세 균형 제어)

  • 김연희;최종덕;이성범;김종윤;이석준;박찬희;김남균
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.11a
    • /
    • pp.233-244
    • /
    • 2002
  • The purpose of this study is to assess the ability of balance control in moving surround using head mount device and force platform and to examine the clinical usefulness of COP parameters. Fifteen patients with stroke and healthy persons were participated. COP parameters were obtained as total path distance, frequency of anterior-posterior and medial-lateral component by FFT analysis, weight-spectrum analysis in the two different conditions; (1) in comfortable standing with opened or closed eyes, (2) in virtual moving surround delivered using HMD to four different moving pattern. In virtual moving surround setting, moving pattern was composed of close-far, superior-inferior tilting(pitch), right-left tilting(roll) and horizontal rotation(yaw) movement. In all parameters, the reliebility of COP analysis system was significantly high. Also, the construct validity compared between fifteen patients with stroke and normal persons was excellent in virtual moving surround condition(p

  • PDF

Position Sensorless Control of Active Magnetic Bearing (자기 베어링의 센서리스 위치 제어)

  • Yim J.S.;Sul S.K.;Ahn H.J.;Choi C.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.420-423
    • /
    • 2003
  • 자기 베어링을 구동하는 코일은 회전축의 위치 정보를 가지고 있다. 따라서 코일의 인덕턴스를 알 수 있으면 위치 센서를 쓰지 않고도 회전축의 위치를 알아낼 수 있다. 본 논문에서는 코일에 고주파 신호를 주입하여 인덕턴스를 알아내고, 이를 통해 회전축의 위치를 추정하는 방법을 제안하고, 그를 이용하여 자기 베어링의 센서리스 제어를 수행한다.

  • PDF

삼중효용 흡수식 냉동기 기술 개발

  • 정시영
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.7-10
    • /
    • 2004
  • 삼중효용 흡수식 냉동기의 기본 원리, 사이를 구성 방법 및 특성, 제품 개발을 위한 핵심 기술에 대하여 알아본다. 현재 널리 사용되는 흡수식 냉동기는 대부분이 이중효용(double effect) 기기이며 그 동안의 많은 기술 축척과 연구개발의 결과, 성능이 향상되어 최근 일본에서 출시되는 신제품은 냉방 COP가 약 1.3을 넘어서고 있다. 그러나 이중효용 흡수식 냉동기로서는 도달 가능한 COP에 한계가 있기 때문에 2-3년 전부터 삼중효용 흡수식 냉동기에 대한 연구가 일본 등에서 활발히 진행되고 있다.(중략)

  • PDF

가정용 공조기의 고효율기술 동향과 전망

  • 황윤제
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.11
    • /
    • pp.41-54
    • /
    • 2002
  • 가정용 공조기에 대하여 에너지소비효율(COP; coefficient of performance)을 향상시켜 전기소모량을 줄일 수 있는 고효율제품의 개발요구가 증가하고 있으므로, 과연 도달 가능한 한계 COP가 어디까지이며 이를 달성하기위하여 어떤 기술이 필요한지에 대한 명확한 개념의 이해가 필요한 시점이다. 따라서 고효율과 관련된 최신기술을 소개함으로서 향후 사업과 기술의 중장기적 목표와 방향을 설정하는데 도움이 되고자 한다.

  • PDF