• Title/Summary/Keyword: conversion loss

Search Result 737, Processing Time 0.028 seconds

Intracorporeal Anastomosis Using Linear Stapler in Laparoscopic Distal Gastrectomy: Comparison between Gastroduodenostomy and Gastrojejunostomy

  • Lee, Hak-Woo;Kim, Hyoung-Il;An, Ji-Yeong;Cheong, Jae-Ho;Lee, Kang-Young;Hyung, Woo-Jin;Noh, Sung-Hoon
    • Journal of Gastric Cancer
    • /
    • v.11 no.4
    • /
    • pp.212-218
    • /
    • 2011
  • Purpose: Intracorporeal anastomosis during laparoscopic gastrectomy is becoming increasingly prevalent. However, selection of the anastomosis method after laparoscopic distal gastrectomy is equivocal because of a lack of technical feasibility and safety. We compared intracorporeal gastroduodenostomy with gastrojejunostomy using linear staplers to evaluate the technical feasibility and safety of intracorporeal anastomoses as well as its' minimally invasiveness. Materials and Methods: Retrospective analyses of a prospectively collected database for gastric cancer revealed 47 gastric cancer patients who underwent laparoscopic distal gastrectomy with either intracorporeal gastroduodenostomy or gastrojejunostomy from March 2011 to June 2011. Perioperative outcomes such as operation time, postoperative complication, and hospital stay were compared according to the type of anastomosis. Postoperative inflammatory response was also compared between the two groups using white blood cell count and high sensitivity C-reactive protein. Results: Among the 47 patients, 26 patients received gastroduodenostomy, whereas 21 patients received gastrojejunostomy without open conversion or additional mini-laparotomy incision. There was no difference in mean operation time, blood loss, and length of postoperative hospital stays. There was no statistically significant difference in postoperative complication or mortality between two groups. However, significantly more staplers were used for gastroduodenostomy than for gastrojejunostomy (n=6) than for gastroduodenostomy and (n=5). Conclusions: Intracorporeal anastomosis during laparoscopic gastrectomy using linear stapler, either gastroduodenostomy or gastrojejunostomy, shows comparable and acceptable early postoperative outcomes and are safe and feasible. Therefore, surgeons may choose either anastomosis method as long as oncological safety is guaranteed.

DC Characteristics Analysis of Various AC loads for Hybrid Distribution (하이브리드 급전을 위한 다양한 가정용 교류부하의 직류특성연구)

  • Lee, Young-Jin;Han, Dong-Ha;Choi, Jung-Muk;Jeong, Byong-Hwan;Kim, Dong-Jin;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • Recently, the use of DC power increased due to the increased use of digital load. Power factor of input current decrease and input current harmonics increase, and conversion loss which is occurred in the AC / DC converter is a problem to provide the proper DC voltage to the device equipped with an internal AC / DC converter. Hybrid system supplies the AC power and DC power to AC load (motor load and the transformer load) and DC loads (computers, TV, LED fluorescent light) at the same time it supplies the renewable energy and utility energy taken power from Utility to user for improving the efficiency and renewable energy improvements in ease of use. This paper studies DC characteristics of traditional AC load for Hybrid distributions.

Cloning and Characterization of UDP-glucose Dehydrogenase from Sphingomonas chungbukensis DJ77

  • Yoon, Moon-Young;Park, Hye-Yeon;Park, Hae-Chul;Park, Sung-Ha;Kim, Sung-Kun;Kim, Young-Chang;Shin, Mal-shik;Choi, Jung-Do
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1547-1552
    • /
    • 2009
  • Sphingomonas chungbukensis DJ77 has the ability to produce large quantities of an extracellular polysaccharide that can be used as a gelling agent in the food and pharmaceutical industries. We identified, cloned and expressed the UDP-glucose dehydrogenase gene of S. chungbukensis DJ77, and characterized the resulting protein. The purified UDP-glucose dehydrogenase (UGDH), which catalyzes the reversible conversion of UDP-glucose to UDPglucuronic acid, formed a homodimer and the mass of the monomer was estimated to be 46 kDa. Kinetic analysis at the optimal pH of 8.5 indicated that the $K_m\;and\;V_{max}$ for UDP-glucose were 0.18 mM and 1.59 mM/min/mg, respectively. Inhibition assays showed that UDP-glucuronic acid strongly inhibits UGDH. Site-directed mutagenesis was performed on Gly9, Gly12 Thr127, Cys264, and Lys267. Substitutions of Cys264 with Ala and of Lys267 with Asp resulted in complete loss of enzymatic activity, suggesting that Cys264 and Lys267 are essential for the catalytic activity of UGDH.

Design of Spatial Relationship for 3D Geometry Model (3차원 기하모델에 대한 공간 관계 연산 설계)

  • Yi Dong-Heon;Hong Sung-Eon;Park Soo-Hong
    • Spatial Information Research
    • /
    • v.13 no.2 s.33
    • /
    • pp.119-128
    • /
    • 2005
  • Most spatial data handled in GIS is two-dimensional. These two-dimensional data is established by selecting 2D aspects form 3D, or by projecting 3D onto 2D space. During this conversion, without user's intention, data are abstracted and omitted. This unwanted data loss causes disadvantages such as restrictingof the range of data application and describing inaccurate real world. Recently, three dimensional data is getting wide interests and demands. One of the examplesis Database Management System which can store and manage three dimensional spatial data. However, this DBMS does not support spatial query which is the essence of the database management system. So, various studies are needed in this field. This research designs spatial relationship that is defined in space database standard using the three-dimension space model. The spatial data model, which is used in this research, is the one defined in OGC for GMS3, and designing tool is DE-9IM based on Point-Set Topology blow as the best method for topological operation.

  • PDF

Case Study on 12kW Building Integrated Photovoltaic System (12kW급 건물일체형 태양광발전시스템 사례분석)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;So, Jung-Hoon;Yu, Gwon-Jong;Kim, Jun-Tae;Lee, Kil-Song
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • We intend to describe a 12kW building-integrated photovoltaic system which was applied into the south wall of a new building. This study showed the results that were appeared from describing the PV module manufacture and installation process, and performing generation performance analysis of BIPV system. From the result we confirmed that the generation performance of the BIPV system was changed by season. The performance ratio(PR) was about 83.6% in winter and it means that performance of this BIPV system was so good in that season. On the other hand, the PR in summer was about 75.0% dropped about 8%. It was believed that the change was influenced by the reduction of solar radiation irradiated into the PV modules by installation position and rainy spell in summer. And we also confirmed that low irradiation condition is cause of the additional loss in the total PV system. In this case, the efficiency ratio of PCS drops significantly at low input loads and the average conversion efficiency of PCS in summer was 76.4% decreased about 10% from 86% in winter.

Design and Fabrication of 2 GHz Doubly Balanced Star Mixer using Novel Balun (새로운 발룬 회로를 이용한 2 GHz 대역 이중 평형 Star 혼합기의 설계 및 제작)

  • 김선숙;이종환;염경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.44-50
    • /
    • 2004
  • In this paper, a DBM(Doubly Balanced Mixer) of 2 GHz is implemented on FR4 substrate. The structure of doubly balanced mixer requires, in general, two batons and a quad diode. For balun, a novel planar balun using microstrip to CPS is suggested and designed. The suggested balun shows the phase imbalance of 180$^{\circ}$${\pm}$ 1.5$^{\circ}$and the amplitude imbalance of ${\pm}$ 0.2 ㏈ for 1.5 to 2.5 GHz. Using the balun, DBM is succesfully implemented, and the measured conversion loss of up/down converter show about 6 ㏈ over the bandwidth. The balun may be applicable for MMIC DBM with the process supporting backside via thourgh more study.

A Study on SQL Performance-Based IT Application Change Management Process to Prevent Failures of Online Transactions (온라인 거래 장애 방지를 위한 SQL 성능 기반 IT 응용프로그램 변경관리 프로세스 연구)

  • Kim, Jeong-Hwan;Ko, Moo-Seong;Lee, Kyung-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.5
    • /
    • pp.817-838
    • /
    • 2014
  • Test environment on the company that handles a large amount of data such as telecommunications companies and financial institutions, may not always be the same as the production environment, which is caused by conversion of important columns about information and limitation of storage capacity due to the construction cost. Therefore, SQL performance degradation that occurs when the test and production environments are not the same, which is an important cause of connecting to the unexpected failures of online transactions, and it generates financial loss of business, customer complaints, a decrease in reliability. In studies related SQL performance, it has so far been conducted mainly studies of tuning associated with DBMS Optimizer, and it has not been addressed issues of this sector. Therefore, in this paper, I verify the validity about presentation of the advanced SQL Performance-based IT application change management process, in order to prevent failures of the online transactions associated with poor performance of SQL generated by differences in test and production environments.

An analysis of a phase- shifted parallel-input/series-output dual converter for high-power step-up applications (대용량 승압형 위상천이 병렬입력/직렬출력 듀얼 컨버터의 분석)

  • 강정일;노정욱;문건우;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.5
    • /
    • pp.400-409
    • /
    • 2001
  • A new phase-shifted parallel-input/series-output(PISO) dual converter for tush-power step-up applications has been proposed. Since the proposed converter shows a low switch turn-off voltage stress, switching devices with low conduction loss can be employed in order to improve the power conversion efficiency. Moreover, it features a low output capacitor root-mean-square(RMS) current stress, low input current and output voltage ripple contents, and fast control-to-output dynamics compared to its PWM counterpart. In this paper, the operation of the proposed converter is analyzed in detail and its mathematical models and steady-state solutions are presented. A comparative analysis with the conventional PWM PISO dual converter is also provided. To confirm the operation, features, and validity of the Proposed converter, experimental results from an 800W, 24-350Vdc prototype are presented.

  • PDF

Robust Blind Watermarking in Medical Images Using by Polar Transformation (의료영상에서 Polar 변환을 적용한 강인한 블라인드 워터마킹 기법)

  • 김태호;남기철;박무훈
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.241-246
    • /
    • 2004
  • Medical images are being managed more by PACS in general medical institutions. It is important to protect patients from being invaded their privacy related to the images. It is also necessary to confirm the ownership, the right of properity of the medical images and notice whether the data are modified. In this paper, we propose a robust watermarking against RST attacks in medical images on the PACS. The proposed scheme modifies and improves Log-Polar Mapping and Fourier Mellin Transform in order to realize and recover serious image degradation and watermark data loss caused by the conversion between cartesian coordinate and log-polar coordinate. We used the radius and theta Look Up Table to solve the realization of the Fourier Mellin Transform, and inserted a watermark into 2D-DFT magnitudes using Spread Spectrum. Experimental results shows that this method are robust to several attack.

  • PDF

A Study on Entrance Section of Hybrid Wave Power Generation System (하이브리드형 파력발전시스템의 유입구 형상 연구)

  • Oh, Jin-Seok;Jang, Jae-Hee
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.597-601
    • /
    • 2013
  • Recently, many studies about the wave power generation system for the marine structure as the hybrid form in linked with the original features have been made of. Of these, the wave power generation system using oscillating water column(OWC) has function to convert wave energy to electrical energy with original function of the break water structure. In this type of generation system, it is important to make the flow of sea water as much as possible without loss. Output characteristics of wave power generation system depending on entrance section were described in the paper. Also, flow quantity changing with entrance section, velocity of sea water and output of wells turbine were measured by simulating OWC wells turbine model in break water, one of the general marine structure. Finally, entrance section was suggested to enhance the energy conversion efficiency based on the results of simulation.