• 제목/요약/키워드: conventional curing

검색결과 269건 처리시간 0.026초

A study of polymerization shrinkage of composite resins cured by various light intensities

  • Lim, Mi-Young;Hong, Chan-Ui
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.613-613
    • /
    • 2003
  • The purpose of this study was to compare the effect of exponential curing method with conventional curing and two step soft start curing method on polymerization shrinkage of composite resins. Three brands of composite resins (Synergy Duo Shade, Z-250, Supreme) and three brands of light curing units (Spectrum 800, Elipar Highlight, Elipar Trillight) were used. In this study, the diameter of specimen was 5.5mm and height 1.6mm and the specimen was cured for 40 seconds. The shrinkage was measured by custom made linometer. The amount of linear polymerization shrinkage recorded in the computer every 0.5 second for 90 seconds. Each group was measured 10 times.(omitted)

  • PDF

중합방법에 따른 여러 이중중합 레진 시멘트의 기계적 성질 평가 (Evaluation of mechanical properties of several dual-cure resin cements by curing modes)

  • 김수연;박세희;김진우;조경모
    • 구강회복응용과학지
    • /
    • 제31권1호
    • /
    • pp.1-9
    • /
    • 2015
  • 목적: 중합방법 및 측정시기에 따른 여러 이중중합 레진 시멘트의 기계적 성질인 압축강도와 간접인장강도를 비교 평가하는 것이다. 연구 재료 및 방법: 1개의 레진강화형 글래스아이오노머 시멘트인 FujiCEM 2, 2개의 전통적인 이중중합 레진 시멘트인 RelyX ARC와 Multilink N, 2개의 이중중합 자가접착 레진 시멘트인 RelyX U200과 G-CEM LinkAce를 사용하였다. 제조사의 지시에 따라 시멘트를 혼합하여 압축강도와 간접인장강도 측정을 위한 시편을 제작하였다. 중합방법 및 측정시기의 영향을 평가하기 위해 시멘트에 따라 4가지 실험 조건으로 나눴고, 만능시험기로 압축강도와 간접인장강도 측정하였다. 각각의 강도 값을 계산 후 통계처리 하였다. 결과: 압축강도에서는 RelyX ARC의 광중합과 Multilink N의 광중합, 간접인장강도에서는 RelyX ARC의 광중합을 제외하고 모든 중합방법에서 24시간 뒤 측정된 강도가 즉시 측정한 강도보다 더 높은 값을 보여주었다. FujiCEM 2는 시멘트간 비교에서 가장 낮은 강도 값을 보였다(P < 0.05). 결론: 치과용 시멘트 중에서 최근 출시된 이중중합 자가접착 레진 시멘트는 기존의 레진 시멘트와 비교시 제품별로 차이가 있었으나, 압축강도와 간접인장강도에서는 유의한 차이를 보이지 않았다.

플라즈마 광중합기가 복합레진 중합에 미치는 영향 (Effects of plasma arc curing lights on the surface hardness of the composite resins)

  • 이수원;양규호;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.624-632
    • /
    • 2006
  • 기존에 사용하고 있는 할로겐 광중합기는 여러 가지 장점에도 불구하고 중합시간이 오래 걸린다는 문제 때문에 시술시간이 길어지는 단점이 있는데, 최근에 개발된 플라즈마 광중합기는 매우 짧은 시간에 중합시킬 수 있다고 제조회사는 주장하고 있다. 본 연구에서는 임상에서 흔히 상용하고 있는 복합 레진을 광중합 할 때, 할로겐 광중합으로 얻을 수 있는 플라즈마 광중합기의 적절한 중합시간을 알아보고자 한다. 2mm 두께의 레진 샘플을 만들어 광중합 하고 24 시간 후 상, 하면의 미세경도를 측정하였다. point $4^{(R)}$에서는 플라즈마 광중합기로 6초간 중합했을 때 할로겐과 유사한 경도를 얻었지만, $Z250^{(R)}$에서는 $Flipo^{(R)}$만 9초간 중합시 할로겐과 유사한 광중합을 나타냈다. 이번 연구에서 사용한 플라즈마 광중합기는 적어도 6초 혹은 9초정도 광중합 했을 때 할로겐과 유사한 중합을 얻을 수 있다는 것을 알 수 있었다.

  • PDF

치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교 (Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources)

  • 김환;이권용;박성호;정일영;전승범
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF

FTIR을 이용한 복합레진의 중합도 비교 (THE COMPARISON OF LIGHT-CURED COMPOSITE RESIN POLYMERIZATION BY FTIR)

  • 이주현;박호원
    • 대한소아치과학회지
    • /
    • 제30권2호
    • /
    • pp.245-253
    • /
    • 2003
  • 치과용 복합레진의 중합률은 레진 기질내의 이중결합의 전환도를 나타내는 것으로 이는 재료의 물리적 성질과 기계적 성질 및 생체 친화성에 영향을 미친다. 레진의 중합도가 증가하면 취성과 수축이 증가하고 중합도가 낮으면 기계적 물리적 성질이 감소한다. 따라서 본 연구에서는 광중합형 복합레진을 사용하여 플라즈마 아크 중합기 2종, 할로겐 중합기 2종, LED 중합기 2종, pulse-delay curing의 서로 다른 중합방법의 경우를 FTIR 분석법으로 복합레진의 물리적 기계적 성질 및 생체친화성에 영향을 미치는 중합률을 분석하여 다음과 같은 결과를 얻었다. 1. 광중합 복합레진의 중합률은 FTIR로 측정하였을 때 34.52-49.31%사이로 나타났으며 플라즈마 아크 중합의 경우 Flipo는 $39.96{\pm}1.22%$, CrediII는 $45.64{\pm}1.34%$로, 할로겐 중합시 XL3000은 $43.48{\pm}1.34%$, VIP의 mode 4 사용시는 $44.31{\pm}0.72%$, LED의 LUXOMAX는 $49.31{\pm}2.37%$, Elipar Freelight는 $44.51{\pm}0.62%$, pulse-delay curing시에는 $34.52{\pm}0.85%$로 나타났다. 2. 각 중합 방법별로 중합률은 LED 중합 방법을 이용한 LUXOMAX가 다른 실험군에 비하여 가장 높은 중합률을 나타냈으며 pulse-delay curing 방법이 가장 낮은 중합률을 보였다. 3. Flipo 중합기, LUXOMAX 중합기, pulse-delay curing 방법이 다른 중합기와 비교하여 통계적으로 유의한 차이를 보였다(p<0.05). 4. 각 중합방법이 동일한 군 내의 중합기기별 차이에서는 할로겐에서는 광중합기 사이에 중합률의 차이를 보이지 않았으나 플라즈마 아크에서는 CrediII가, LED에서는 LUXOMAX가 중합률이 높았다(p<0.05).

  • PDF

Effects of Fine LWA and SAP as Internal Water Curing Agents

  • de Sensale, Gemma Rodriguez;Goncalves, Arlindo Freitas
    • International Journal of Concrete Structures and Materials
    • /
    • 제8권3호
    • /
    • pp.229-238
    • /
    • 2014
  • Typical high-performance concrete (HPC) mixtures are characterized by low water-cementitious material ratios, high cement contents, and the incorporation of admixtures. In spite of its superior properties in the hardened state, HPC suffers from many practical difficulties such as its sensitivity to early-age cracking (which is associated with self-desiccation and autogenous shrinkage). In this context, conventional curing procedures are not sufficiently effective to address these limitations. In order to overcome this issue, two strategies,which are based on the use of internal reservoirs of water, have been recently developed.One of these strategies is based on the use of lightweight aggregates (LWA), while the other is based on the use of superabsorbent polymers (SAP). This paper studies and compares the efficiency of the LWA and SAP approaches.Moreover, some of the theoretical aspects that should be taken into account to optimize their application for internal curing of HPC are also discussed. Two fine LWA's and one SAP are studied in terms of autogenous deformation and compressive strength. Increasing the amounts of LWAor SAP can lead to a reduction of the autogenous deformation and compressive strength (especially when adding large amounts). By selecting appropriate materials and controlling their amount, size, and porosity, highly efficient internal water curing can be ensured.

Thermal Curing Behavior and Tensile Properties of Resole Phenol-Formaldehyde Resin/Clay/Cellulose Nanocomposite

  • Park, Byung-Dae;Kadla, John F.
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권2호
    • /
    • pp.110-122
    • /
    • 2012
  • This study investigated the effects of layered clay on the thermal curing behavior and tensile properties of resole phenol-formaldehyde (PF) resin/clay/cellulose nanocomposites. The thermal curing behavior of the nanocomposite was characterized using conventional differential scanning calorimetry (DSC) and temperature modulated (TMDSC). The addition of clay was found to accelerate resin curing, as measured by peak temperature ($T_p$) and heat of reaction (${\Delta}H$) of the nanocomposite’ curing reaction increasing clay addition decreased $T_p$ with a minimum at 3~5% clay. However, the reversing heat flow and heat capacity showed that the clay addition up to 3% delayed the vitrification process of the resole PF resin in the nanocomposite, indicating an inhibition effect of the clay on curing in the later stages of the reaction. Three different methods were employed to determineactivation energies for the curing reaction of the nanocomposite. Both the Ozawa and Kissinger methods showed the lowest activation energy (E) at 3% clay content. Using the isoconversional method, the activation energy ($E_{\alpha}$) as a function of the degree of conversion was measured and showed that as the degree of cure increased, the $E_{\alpha}$ showed a gradual decrease, and gave the lowest value at 3% nanoclay. The addition of clay improved the tensile strengths of the nanocomposites, although a slight decrease in the elongation at break was observed as the clay content increased. These results demonstrated that the addition of clay to resole PF resins accelerate the curing behavior of the nanocomposites with an optimum level of 3% clay based on the balance between the cure kinetics and tensile properties.

고출력 발광 다이오드 광중합기의 치면열구전색제 중합능 평가 (Evaluation of High-power Light Emitting Diode Curing Light on Sealant Polymerization)

  • 박영준;이제우;라지영
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.57-63
    • /
    • 2019
  • 이 연구의 목적은 고출력 발광 다이오드 광중합기의 Xtra Power 및 High Power mode의 짧은 중합시간이 레진 치면열구전색제의 중합에 충분한지를 확인하는 것이다. 금속 주형을 이용해 시편을 제작하여 미세경도를 측정하였으며, 기존의 발광 다이오드 광중합기로 중합한 시편의 미세경도와 비교하였다. 그 결과, High Power mode로 8초, Xtra Power mode로 3초 중합한 filled sealant와 High Power mode로 8초, 12초, Xtra Power mode로 6초 중합한 unfilled sealant의 상면과 하면 모두에서 대조군보다 유의하게 낮은 미세경도를 나타냈다(p = 0.000). 이 연구를 통하여 중합 시간과 전색제의 종류를 고려한 특정 조건에서 고출력 발광 다이오드 광중합기의 Xtra Power 및 High Power mode의 짧은 중합시간이 치면열구전색제를 적절히 중합하기에 충분하지 않음을 알 수 있었다.

Surface and Dielectric Properties of Oriental Lacquer Films Modified by UV-Curable Silicone Acrylate

  • Hong, Jin-Who;Kim, Hyun-Kyoung
    • Macromolecular Research
    • /
    • 제14권6호
    • /
    • pp.617-623
    • /
    • 2006
  • In order to achieve an oriental lacquer (OL) film with a thick consistency, UV-curable silicone acrylate (SA) was added to OL by a dual curing process. The addition of 5 wt% UV-curable SA to the OL fomulation enabled the preparation via a single drying step of a $77{\mu}m-thick$ film exhibiting excellent surface properties. FTIR-ATR was used to investigate the effect of UV-curable SA on the behavior of film formation during curing, and the relaxation behavior of the produced films was investigated by dielectric spectroscopy. Dielectric properties were measured in the frequency range $10^{-2}-10^5\;Hz$ at various temperatures between -100 and $200^{\circ}C$. The results demonstrated that OL modified by UV-curable SA has a higher glass transition temperature and stronger secondary relaxation at a lower temperature than the conventional OL system. The OL film modified with UV-curable SA was presumed to be harder at the surface and tougher than conventional OL film.

발광 다이오드 광중합기의 복합레진 중합 평가 (Evaluation of New LED Curing Light on Resin Composite Polymerization)

  • 강지은;전새로미;김종빈;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제41권2호
    • /
    • pp.152-156
    • /
    • 2014
  • 최근 도입된 광범위 스펙트럼의 발광 다이오드 광중합기는 4개의 램프로 구성되어 있으며 다양한 중합 모드를 가지고 있다. 이 연구는 광범위 스펙트럼 발광 다이오드($VALO^{(R)}$, Ultradent, USA) 광중합기와 기존의 발광 다이오드 광중합기 ($Elipar^{TM}$ Freelight 2, 3M ESPE, USA)의 효율을 미세경도 시험을 통해 비교하였다. 연구에 사용한 광중합기는 $VALO^{(R)}$$Elipar^{TM}$ Freelight 2이며 중합 시간은 제조사의 지시에 따랐다. $37^{\circ}C$의 생리식염수에 중합된 레진 시편을 24시간 동안 보관한 후 미세경도 시험을 시행하였다. 시편 상부와 하부의 복합레진 미세경도는 공분산분석을 시행하였다. 광범위 스펙트럼의 발광 다이오드 광중합기를 이용하여 고성능 모드에서 4초, 플라즈마 모드에서 20초 광중합을 실시한 복합레진 시편의 상부는 기존의 발광 다이오드 광중합기에 비해 미세경도가 증가하였으나(p < 0.05), 시편의 하부에서는 실험에 사용된 광중합기 간에 유의성 있는 차이를 보이지 않았다.