• 제목/요약/키워드: convection heat losses

검색결과 22건 처리시간 0.034초

연성해석을 이용한 초고압 DSES 온도상승예측 (An Estimation Technology of Temperature Rise in DSES using Three-Dimensional Coupled-Field Multiphysics)

  • 윤정훈;안희섭;최종웅;박석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.847_848
    • /
    • 2009
  • This paper shows the temperature rise of the high voltage GIS bus bar. The temperature rise in GIS bus bar is due to Joule‘s losses in the conductor and the induced eddy current in the tank. The power losses of a bus bar calculated from the magnetic field analysis are used as the input data for the thermal analysis to predict the temperature. The required analysis is a couple-field Multiphysics that accounts for the interactions between three-dimensional AC harmonic magnetic and fluid fields. The heat transfer calculation using the fluid analysis is done by considering the natural convection and the radiation from the tank to the atmosphere. Consequently, because temperature distributions by couple-field Multiphysics (coupled magnetic-fluid) have good agreement with results of temperature rise test, the proposed couple-field Multiphysics technique is likely to be used in a conduction design of the single-pole and three pole-encapsulated bus bar in GIS..

  • PDF

연성해석을 이용한 초고압 모선부 온도 상승 예측 기술 (An Estimation Technology of Temperature Rise in GIS Bus Bar using Three-Dimensional Coupled-Field Multiphysics)

  • 윤정훈;안희섭;최종웅;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.675-676
    • /
    • 2006
  • This paper shows the temperature rise of the high voltage GIS bus bar. The temperature rise in GIS bus bar is due to Joule's losses in the conductor and the induced eddy current in the tank. The power losses of a bus bar calculated from the magnetic field analysis are used as the input data for the thermal analysis to predict the temperature. The required analysis is a couple-field Multiphysics that accounts for the interactions between three-dimensional AC harmonic magnetic and fluid fields. The heat transfer calculation using the fluid analysis is done by considering the natural convection and the radiation from the tank to the atmosphere. Consequently, because temperature distributions by couple-field Multiphysics (coupled magnetic-fluid) have good agreement with results of temperature rise test, the proposed couple-field Multiphysics technique is likely to be used in a conduction design of the single-pole and three pole-encapsulated bus bar in CIS..

  • PDF

비대칭 사다리꼴 핀의 온도분포와 열손실 해석 (Analysis of Temperature Distribution and Heat Loss for an Asymmetric Trapezoidal Fin)

  • 강형석;송년주
    • 대한기계학회논문집B
    • /
    • 제36권4호
    • /
    • pp.377-383
    • /
    • 2012
  • 변화되는 위 측면 기울기를 가진 비대칭 사다리꼴 핀의 온도분포가 2차원 해석적 방법을 사용하여 조사되어 진다. 이 비대칭 핀을 위해, 내부유체로부터 내벽까지의 대류, 내벽으로부터 핀 바닥까지의 전도, 그리고 핀 바닥을 통한 전도가 동시에 고려된다. 무차원 핀 길이와 높이좌표 변화에 따른 온도 형상이 보여진다. 또한 핀 아래 끝에서 온도 변화가 핀 형상계수의 함수로 나타내어진다. 핀 길이의 변화에 따라 핀 바닥을 통한 열손실과 각 면으로부터의 열손실들이 비교된다. 결과들 중 하나는 핀형상계수가 증가함에 따라 핀 아래 끝에서 온도는 선형적으로 감소함을 보여준다.

25.8kV 25kA 3상 GIS 모선의 온도상승 예측 (Temperature Rise Prediction of 25.8kV 25kA Three-phase GIS Bus Bar)

  • 김중경;한성진;오연호;박경엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.894-895
    • /
    • 2007
  • This paper presents coupled analysis between finite element method and analytic technique for predicting temperature rise of 25.8kV 25kA three-phase GIS bus bar. The power losses and temperature distribution of three-phase GIS bus bar model are analyzed by magneto-thermal finite element method. The heat transfer coefficients on the boundaries are analytically calculated by applying Nusselt number considering material constant and model geometry for the natural convection. And these are used as the input data to predict the temperature rise of three-phase GIS bus bar model by coupled magneto-thermal F.E.A. The predicted temperature of 25.8kV 25kA three-phase GIS bus bar model shows good agreement with the experimental data.

  • PDF

자계-열계를 결합한 초고압 GIS용 모선의 온도상승 예측 (Prediction of Temperature Rise in EHV GIS Bus Bar by Coupled Magneto-Thermal F.E A)

  • 김중경;민경조;김한균;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.990-992
    • /
    • 2005
  • This paper presents a new magneto-thermal finite element analysis for predicting the temperature rise of the EHV GIS bus bar. The power losses of a bus bar calculated by the magnetic field analysis are used as the input data to predict the temperature rise for the thermal analysis. The heat-transfer coefficients on the boundaries are analytically calculated by applying the Nusselt number considering material constant and model geometry for the natural convection. The temperature distribution in a bus bar by coupled magneto-thermal finite element analysis shows good agreement with the experimental data.

  • PDF

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

소형 Slot less PMSM의 coil 배치에 따른 최적 설계 및 열 내구성 분석 (A Study on Optimal Design According to Change of Coil Distribution in Slot Less Type Permanent Magnet Synchronous Motor)

  • 김용태;고덕화;김규화;백성민;김규탁
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.27-32
    • /
    • 2017
  • In this paper, slot less type high-speed and compact motor was designed. it was selected through change of stator coil distribution for the optimal performance of the motor. In this paper, designed motor was expected to be very vulnerable to heat dissipation in a compact motor. Therefore, to ensure reliability in the design result, winding and permanent magnet damage caused by the losses of motor was analyzed by thermal analysis and demagnetization analysis. Using the result, whether motor burnout was confirmed by motor performance degradation and insulation breakdown.

가정용 냉장고의 에너지 노즈부 열전달 특성에 관한 연구 (A Study on the Heat Transfer Performance of an Energy-Nose Section in a Household Refrigerator-Freezer)

  • 이무연;이동연;김용찬
    • 대한기계학회논문집B
    • /
    • 제31권6호
    • /
    • pp.574-580
    • /
    • 2007
  • The objective of this article is to present an analysis of all heat transfer paths through the energy nose under closed door conditions when refrigeration system of household refrigerator-freezer is operating on. Both experimental and numerical methods are suggested as a means of determining the overall energy nose load amount as well as the load due to each pathway such as mullion section and F and R sides of the household refrigerator-freezer. In other words, all loads determined in this article are just energy nose and not the loads seen by the refrigeration system. We suggest good ideas for improving the heat transfer losses such as conduction and convection through the energy nose. As we can be known from the experimental test results, it is effective to prevent the heat loss of a mullion section. And energy efficiency is also decreased approximately 6% compared to that of a baseline sample test result. As we can be known from the Ansys 8.1 analysis, it is shown the steady state temperature distribution in figures from 6 to 8. And the direction of the heat flow through the energy nose section is also easily seen from that In conclusion, the article is focused on an energy nose section in household refrigerator-freezer for practical proposes which is the energy saving in a household refrigerator-freezer. And the method suggested may be applied to any make or model to aid in the search for high efficient energy nose section of household side by side refrigerator-freezer as well as top mounted refrigerator-freezer, commercial refrigerator and so on.

수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달 (Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel)

  • 유갑종;이진호;김현우
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.29-41
    • /
    • 1999
  • 본 연구에서는 돌출된 단일 모듈이 부착된 수직 채널내의 3차원 자연대류 특성을 실험적으로 조사하였으며, 특히 모듈로부터 대류에 의한 열에너지 제거에 초점을 두었다. 채널내의 유동장은 smoke-method를 이용하여 가시화 하였다. 또한 채널내부, 수직벽면 및 모듈표면의 국소온도를 열전대와 열플럭스 센서를 이용하여 측정하여 복사와 전도에의한 열손실량을 계산하였다. 실험결과 대류열전달은 모듈 하부의 모서리 부근에서 가장 활발히 일어나고, 모듈 상부에서의 재순환영역은 열전달을 감소시킴을 알 수 있으며 임계 채널간격비를 예측할 수 있는 상관식을 레일리히수의 함수로 구하였다. 또한 $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$의 범위에서 수정 채널 레일리히수의 함수로써 평균 누셀트수와의 상관식을 구하였다.

  • PDF

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF