• Title/Summary/Keyword: control vibration

Search Result 4,111, Processing Time 0.032 seconds

Experimental Model Analysis of Double Floor (실험적 모드해석법에 의한 이중바닥구조의 동특성 해석)

  • 변근주;노병철;이헌주;이호범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.207-212
    • /
    • 1993
  • When constructing highly precise production plants, for example, super LSI plants or semiconductor plants, it is important to take the necessary control countermeasures into consideration to obtain the working microvibration environment, which is directly related to product precision. Working environment of a clean room means vibration-free and there are only ultra-miro vibration which human cannot sense. In order to provide an place having a vibration-free working environment with only ultra-micro vibration it is necessary to posses a great number of vibration isolation technlogies, wide-ranging and abundant survey and teat data, and a high level of knowledge enabling comprehensive judgments to be made. In this study, experimental modal analysis is used to analyze the dynamic characteristics of double floor for vibration-proofing near apparatus which generate vibration. It is concluded that the double floor system with rubber pad inserted between floor panel and pedestal is good for vibration proof.

  • PDF

Investigation on Transient Vibration of Piping System to Heater in a Power Plant (발전소 가열기 급수용 배관계 이상 진동 고찰)

  • 양경현;조철환;배춘희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.975-978
    • /
    • 2004
  • There was transient vibration on the piping system from #4 heater to the deaerator in a power plant. We found it was resulted from resonance between the natural vibration of the piping system and vibration induced by flow of feedwater. We verified it would reduce vibration by increasing stiffness of the piping system. Therefore we concluded that it would be generally better to increase stiffness of the piping system to reduce vibration amplitude of 10Hz low for big sized piping systems.

  • PDF

A Study on the Development of a Hybrid Electromagnetic Actuator Against Microvibration (미진동 저감을 위한 복합형 전자기식 작동기의 개발에 대한 연구)

  • Moon, S.J.;Park, S.H.;Jeong, J.A.;Huh, Y.C.;Kim, C.H.;Choi, S.M.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.475-483
    • /
    • 2011
  • A hybrid electromagnetic actuator with an air mount is designed so as to achieve the desired isolation reduce the vibration efficiency on the floor vibration. The performance specification of the hybrid electromagnetic actuator is determined based on the vibration criterion for vibration-sensitive equipment. In the design stage of the electromagnetic actuator, the simple reluctance method is adapted to analyze magnetic circuits. The result is verified by finite element analysis using ANSYS Emag. Finally, in order to confirm the design performance, a dynamic characteristic test is carried out for the prototype of a hybrid electromagnetic actuator.

Study of the Non-linearity of Cable Damper to Enhance Damping Performance of Stay Cable (사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구)

  • Seo, Ju-Won;Koh, Hyun-Moo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.9
    • /
    • pp.785-796
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigates the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a potential energy loss ratio of cable vibration, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, three types of multi-mode patterns such as ambient vibration, support excitation and rain-wind induced vibration are assumed. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5 and in case of support excitation or rain-wind induced vibration it is between 0.5 and 1.0.

Active Control of Vibration Isolation Table Using Air-spring (공기스프링을 이용한 방진 테이블의 능동 제어)

  • An, Chae-Hun;Yim, Kwang-Hyeok;Kwon, Hyeok-Jin;Jung, Jin-Hoon;Bae, Yoon-Hwa;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.831-836
    • /
    • 2006
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.

  • PDF

A Study on the Characteristics of Vibration and Noise to be occurred to operating Elevator in Apartment (공동주택 엘리베이터 운행시 발생하는 진동ㆍ소음 특성에 관한 연구)

  • 배동명;신창혁;김도균
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.938-943
    • /
    • 2003
  • In accordance with the tendance to construct high-rise apartment buildings, the elevators tend to high speed up and to the drive more frequently. So, the problem of vibration and noise produced by the operating elevator has been treated as an important subject all the more. In this research, the actual levels of vibration and noise which generated and transmitted by the elevator operation in apartment buildings were measured and these characteristics were analysed to examine the countermeasures to be able to reduce the these vibration and noise level, and to design the several vibration and noise control.

  • PDF

Feasibility Study on the Vibration Reduction for Hydraulic Breaker by the Dynamic Vibration Absorber (동흡진기를 이용한 유압 브레이커의 진동 감쇠 가능성에 관한 연구)

  • Kang, Young Ky;Jang, Ju Seop
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.65-71
    • /
    • 2021
  • In this paper, the development of a vibration reduction device for hydraulic breakers was studied. Generally, a hydraulic breaker generates shock vibrations while working. When using vibration-proof rubber, shock vibrations are reduced, but without this, shock vibrations are repeatedly generated. Such repeated shock vibrations not only lower the fatigue strength of hydraulic breakers and excavators equipped with them but also increase the fatigue of the workers. This paper proposes the possibility of reducing shock vibration by using a dynamic vibration absorber.

Investigation for the Characters of Human Perception Level according to Acceleration Value Parameters (가속도 크기 변수에 따른 수직진동에 대한 인지수준 고찰)

  • Lee, MinJung;Han, SangWhan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.731-740
    • /
    • 2014
  • Occupants induced floor vertical vibrations may cause other occupant's annoyance and lead to social loss. To help control such floor vibrations, several criteria have been developed mostly based on human perception tests and floor vibration tests. Floor vibration is evaluated by comparison with criteria and vibration parameters of subject floor, such as frequency, damping ratio, acceleration value, vibration duration time and occurrence frequency. Three acceleration value parameters are used in criteria; peak acceleration, rms acceleration and VDV, when a floor vibration serviceability is evaluated. Meanwhile rms acceleration and peak acceleration are adopted as vibration limit value in criteria and researches of human perception for vibration. Occupants induced floor vibration is transient rather than steady state. However, rms acceleration is not reliable parameter for evaluating transient vibration. The objective of this study is to investigate the characters of human perception level according to acceleration value parameters for vibration induced by heel impacts and walking activities.

The standard deviations for eigenvalues of the closed-loop systems with random parameters

  • Chen, Su Huan;Liu, Chun;Chen, Yu Dong
    • Structural Engineering and Mechanics
    • /
    • v.18 no.3
    • /
    • pp.331-342
    • /
    • 2004
  • The vibration control problem of structures with random parameters is discussed, which is approximated by a deterministic one. A method for calculating the standard deviations of eigenvalues of the closed-loop systems is presented by using the random perturbation. The method presented in this paper will not require the distribution function of the random parameters of the systems other than their means and variances. Similarly, the distribution function of the random eigenvalues will not be computed other than their means and variances. The standard deviations of eigenvalues of the uncertain closed-loop systems can be used to estimate the stability robustness. The present method is applied to a vibration control system to illustrate the application. The numerical results show that the present method is effective.

Study on Vibration Characteristics after Applying Variable Speed Control to Constant Speed Fans used in a Power Plant (발전소 통풍계통의 가변속 적용 후 진동특성에 관한 연구)

  • Cho, C.W.;Song, O.S.;Yang, K.H.;Kim, G.Y.;Cho, S.T.;Moon, H.D.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.88-94
    • /
    • 2009
  • In this paper, vibration characteristics after applying variable speed control to fans with a rated speed used in a power plant are studied by performing experiments and analyzing finite element models. Then the campbell diagram is presented to verify the reason of the abnormal vibration measured from fan structure during variable operation of Forced Draft Fan & Induced Draft Fan. According to results, it is found that amplitude of acceleration increases abruptly when a 2X harmonic component meets the natural frequency of fan rotor. Therefore it is very important thing that investigate exactly dynamic characteristics for the rotor at variable speed zone before applying variable speed control to a rotor with a rated speed.

  • PDF