• Title/Summary/Keyword: control technology

Search Result 29,806, Processing Time 0.053 seconds

Design and implementation of fast output sampling feedback control for shape memory alloy actuated structures

  • Dhanalakshmi, K.;Umapathy, M.;Ezhilarasi, D.;Bandyopadhyay, B.
    • Smart Structures and Systems
    • /
    • v.8 no.4
    • /
    • pp.367-384
    • /
    • 2011
  • This paper presents the design and experimental evaluation of fast output sampling feedback controller to minimize structural vibration of a cantilever beam using Shape Memory Alloy (SMA) wires as control actuators and piezoceramics as sensor and disturbance actuator. Linear dynamic models of the smart cantilever beam are obtained using online recursive least square parameter estimation. A digital control system that consists of $Simulink^{TM}$ modeling software and dSPACE DS1104 controller board is used for identification and control. The effectiveness of the controller is shown through simulation and experimentation by exciting the structure at resonance.

Simple Speed Control Algorithm for DC Motors

  • Nguyen, Ba-Hai;Ngo, Hai-Bac;Ryu, Jee-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.510-513
    • /
    • 2009
  • In this paper, a novel speed control algorithm of DC motors is presented. The key contribution here is a simple speed controller only with speed feedback and without an inner current control loop. This is possible by adjusting the reference speed based on a certain rule. Therefore, the proposed speed controller here becomes simpler while maintaining the control performance. Moreover, with the proposed controller, the system response can be tuned with less complexity. This proposed control method is investigated both mathematically and experimentally.

  • PDF

Direct Adaptive Fuzzy Sliding Mode Control for Under-actuated Uncertain Systems

  • Su, Shun-Feng;Hsueh, Yao-Chu;Tseng, Cio-Ping;Chen, Song-Shyong;Lin, Yu-San
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.4
    • /
    • pp.240-250
    • /
    • 2015
  • The development of the control algorithms for under-actuated systems is important. Decoupled sliding mode control has been successfully employed to control under-actuated systems in a decoupling manner with the use of sliding mode control. However, in such a control scheme, the system functions must be known. If there are uncertainties in those functions, the control performance may not be satisfactory.In this paper, the direct adaptive fuzzy sliding mode control is employed to control a class of under-actuated uncertain systems which can be regarded as a combination of several subsystems with one same control input. By using the hierarchical sliding control approach, a sliding control law is derived so as to make every subsystem stabilized at the same time. But, since the system considered is assumed to be uncertain, the sliding control law cannot be readily facilitated. Therefore, in the study, based on Lyapunov stable theory a fuzzy compensator is proposed to approximate the uncertain part of the sliding control law. From those simulations, it can be concluded that the proposed compensator can indeed cope with system uncertainties. Besides, it can be found that the proposed compensator also provide good robustness properties.

The design method research of the control system for Autonomous Underwater Vehicle (AUV) using Linear Matrix Inequality (LMI)

  • Nasuno, Youhei;Shimizu, Etsuro;Aoki, Taro;Yomamoto, Ikuo;Hyakudome, Tadahiro;Tsukioka, Satoshi;Yoshida, Hiroshi;Ishibashi, Shojiro;Ito, Masanori;Sasamoto, Ryoko
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1060-1065
    • /
    • 2005
  • An Independent Administrative Corporation Japan Agency for Marine-Earth Science and Technology (JAMSTEC) is developing light-and-small Autonomous Underwater Vehicles (AUV)$^{1)}$, named 'MR-X1' (Marine Robot Experimental 1), which can cruise, investigate and observe by itself without human's help. In this paper, we consider the motion control problem of 'MR-X1' and derive a controller. Since the dynamic property of 'MR-X1' is changed by the influence of the speed, the mathematical model of 'MR-X1' becomes the nonlinear model. In order to design a controller for 'MR-X1', we generally apply nonlinear control theories or linear control theories with some constant speed situation. If we design a controller by applying Linear Quadratic (LQ) optimal control theory, the obtained controller only compensates t e optimality at the designed speed situation, and does not compensate the stability at another speed situations. This paper proposes a controller design method using Linear Matrix Inequalities (LMIs)$^{2),3),4)}$, which can adapt the speed variation of 'MR-X1'. And examples of numerical analysis using our designed controller are shown.

  • PDF

Nonlinear $H_{\infty}$ control to semi-active suspension

  • Sampei, Mitsuji;Kubota, Kenta;Hosokawa, Atsukuni;Laosuwan, Patpong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.287-290
    • /
    • 1995
  • Recently H$_{\infty}$ control theory for nonlinear systems based on the Hamilton-Jacobi inequality has been developed. In this paper, we apply the state feedback controller solved via Riccati equation to a semi-active suspension model, two degree of freedom vehicle model, and show that it is effective for vibration control..

  • PDF

A Study on Enforcement Effects of Radiation Safety Control Regulations for Diagnostic X-ray Equipments (진단용 방사선안전관리 현황에 관한 연구)

  • Sung, Mo-Il;Park, Myeong-Hwan;Kwon, Duk-Moon;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipments and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of the respondents realized the importance of the radiation safety control system, but about a half of them revealed that the regulations were not well observed in accordance with their purposes. Only 43.9% of the respondents took an active part in quality control and safety control of radiation. And respondents responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Trainings for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipments. And management of organizations using diagnostic X-ray equipments have to understand and stress the importance of radiation safety control system.

  • PDF

The optimization study of core power control based on meta-heuristic algorithm for China initiative accelerator driven subcritical system

  • Jin-Yang Li;Jun-Liang Du;Long Gu;You-Peng Zhang;Cong Lin;Yong-Quan Wang;Xing-Chen Zhou;Huan Lin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.452-459
    • /
    • 2023
  • The core power control is an important issue for the study of dynamic characteristics in China initiative accelerator driven subcritical system (CiADS), which has direct impact on the control strategy and safety analysis process. The CiADS is an experimental facility that is only controlled by the proton beam intensity without considering the control rods in the current engineering design stage. In order to get the optimized operation scheme with the stable and reliable features, the variation of beam intensity using the continuous and periodic control approaches has been adopted, and the change of collimator and the adjusting of duty ratio have been proposed in the power control process. Considering the neutronics and the thermal-hydraulics characteristics in CiADS, the physical model for the core power control has been established by means of the point reactor kinetics method and the lumped parameter method. Moreover, the multi-inputs single-output (MISO) logical structure for the power control process has been constructed using proportional integral derivative (PID) controller, and the meta-heuristic algorithm has been employed to obtain the global optimized parameters for the stable running mode without producing large perturbations. Finally, the verification and validation of the control method have been tested based on the reference scenarios in considering the disturbances of spallation neutron source and inlet temperature respectively, where all the numerical results reveal that the optimization method has satisfactory performance in the CiADS core power control scenarios.

Implementation of Tone Control Module in Anchor System for Improved Audio Quality

  • Seungwon Lee;Soonchul Kwon;Seunghyun Lee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.10-21
    • /
    • 2024
  • Recently, audio systems are changing the configuration of conventional sound reinforcement (SR) systems and public address (PA) systems by using audio over IP (AoIP), a technology that can transmit and receive audio signals based on internet protocol (IP). With the advancement of IP technology, AoIP technologies are leading the audio market and various technologies are being released. In particular, audio networks and control hierarchy over peer-to-peer (Anchor) technology based on AoIP is a system that transmits and receives audio signals over a wide bandwidth without an audio mixer, creating a novel paradigm for existing audio system configurations. Anchor technology forms an audio system by connecting audio sources and output equipment with On-site audio center (OAC), a device that can transmit and receive IP. Anchor's receiving OAC is capable of receiving and mixing audio signals transmitted from different IPs, making it possible to configure a novel audio system by replacing the conventional audio mixer. However, Anchor technology does not have the ability to provide audio effects to input devices such as microphones and instruments in the audio system configuration. Due to this, when individual control of each audio source is required, there is a problem of not being able to control the input signal, and it is impossible to individually affect a specific input signal. In this paper, we implemented a tone control module that can individually control the tone of the audio source of the input device using the audio processor core in the audio system based on Anchor technology, tone control for audio sources is possible through a tone control module connected to the transmitting OAC. As a result of the study, we confirmed that OAC receives the signal from the audio source, adjusts the tone and outputs it on the tone control module. Based on this, it was possible to solve problems that occurred in Anchor technology through transmitting OAC and tone control modules. In the future, we hope that the audio system configuration using Anchor technology will become established as the standard for audio equipment.

Adaptive Mission Control Architecture with Flexible Levels of Autonomy (유연한 자율화 수준의 적응형 임무통제 아키텍처)

  • Wonik Park;Hojoo Lee;Joonsung Choi;Tokson Choe;Chonghui Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.265-276
    • /
    • 2024
  • The future battlefield operation concept does not focus on advanced and complete weapon systems, but requires a new battlefield operation concept that can effectively demonstrate offensive power by combining a large number of low-cost, miniaturized weapons. Recently, research on the autonomous application of major technologies that make up the mission control system is actively underway. However, since the mission control system is still dependent on the operator's operating ability when operating multiple robots, there are limitations to simply applying the automation technology of the existing mission control system. Therefore, we understand how changes in operator capabilities affect multi-robot operation and propose an adaptive mission control architecture design method that supports multi-robot integrated operation by adjusting the level of autonomy of the mission control system according to changes in operator capability.

Intelligent building light control system based on wireless sensor network (무선 센서 네트워크 기반의 빌딩 조명 제어 시스템)

  • Kang, Jeong-Hoon;Yoo, Jun-Jae;Yoon, Myung-Hyun;Lee, Myung-Soo;Lim, Ho-Jung;Lee, Min-Goo;Jang, Dong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.174-176
    • /
    • 2006
  • Sensor network supports data delivery from Physical world to cyber space. Sensors get physical events then wireless network transfers sensor data to service server. We use sensor network technology to light control system for intelligent building. In ubiquitous computing environment. wireless sensor network is basic tool for intelligent service. In this paper, we propose intelligent building light control system based on wireless sensor network. It is implemented using previous light control product, can be adopted to present building light system.

  • PDF