• Title/Summary/Keyword: control suitability

Search Result 300, Processing Time 0.034 seconds

Development of an Assessment Tool for Drinking Motives and Problem Drinking in Female University Students (여대생 음주동기와 문제음주 측정도구 개발)

  • Wie, Seoung Uk;Jung, Moon Hee
    • Research in Community and Public Health Nursing
    • /
    • v.25 no.4
    • /
    • pp.225-236
    • /
    • 2014
  • Purpose: The purpose of the study is to develop a tool that can identify drinking motives and measure the degree of problem drinking in female university students. Methods: From June 25th, 2012 to September 21st, 2012, a methodological study was carried out on this subject. A basic questionnaire was made based on research literature and interviews with 8 female university students. The subjects who participated in the survey for factor analysis were 397 female university students from 2 universities in G Metropolitan City. Results: Exploratory and confirmatory factor analyses were conducted using PASW and AMOS 18.0. The developed tool was found to be acceptable in terms of construct validity and modeling suitability. The questionnaire comprised 16 questions on drinking motives in 4 sub-categories including 'relief' (4 questions), 'friendship' (3 questions), 'consolation' (4 questions), and 'escape' (5 questions). Problem drinking consisted of 11 questions in 3 different sub-categories including 'loss of control,' 'health hazards,' and 'sexual hazards.' Conclusion: The questionnaire was proved to have reliability and validity. Finally, the researcher suggests that this questionnaire is adequate for assessing drinking motives and problem drinking of female university students.

Quantitative Risk Reduction Model according to SIL allocated by Risk Graph for Railway Platform Door System (Risk Graph에 의해 할당된 SIL에 따른 철도 승강장 도어 시스템의 정량적 Risk 저감 모델)

  • Song, Ki Tae;Lee, Sung Ill
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.141-148
    • /
    • 2016
  • There exists required safety integrity level (SIL) to assure safety in accordance with international standards for every electrical / electronics / control equipment or systems with safety related functions. The SIL is allocated from lowest level (level 0) to highest level (level 4). In order to guarantee certain safety level that is internationally acceptable, application of methodology for SIL allocation and demonstration based on related international standards is required. Especially, in case of the SIL allocation method without determining of quantitative tolerable risk, the additional review is needed to check whether it is suitable or not is required. In this study, the quantitative risk reduction model based on the safety integrity allocation results of railway platform screen door system using Risk Graph method has been examined in order to review the suitability of quantitative risk reduction according to allocated safety integrity level.

Development of an Evaluation Protocol for a Bus Seat (버스 승객석의 인간공학적 평가 방법 개발)

  • Park, Jangwoon;Lee, Hyewon;Choi, Younggeun;Park, Kwangae;Kim, Moonjin;You, Heecheon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.41 no.1
    • /
    • pp.74-78
    • /
    • 2015
  • A bus seat is required to be ergonomically designed in terms of its shape and physical properties to increase seating comfort. The present study is intended to develop a systematic bus seat evaluation protocol based on seating comfort. A total of 48 participants evaluated 12 parts (seat belt, recliner, armrest, headrest, upper-back support, lumbar support, seatback bolster, seatback overall, hip support, thigh support, seatpan bolster, and seatpan overall) of 12 bus seats with 17 subjective comfort measures (e.g., convenience of control, suitability of size, and overall comfort). Lastly, ergonomic features of shape and physical properties of each seat part were identified based on the subject evaluation analysis results. The developed bus seat evaluation protocol can be applied to evaluate various types of seats.

Flexural behaviour of CFST members strengthened using CFRP composites

  • Sundarraja, M.C.;Prabhu, G. Ganesh
    • Steel and Composite Structures
    • /
    • v.15 no.6
    • /
    • pp.623-643
    • /
    • 2013
  • Concrete filled steel tubular members (CFST) become a popular choice for modern building construction due to their numerous structural benefits and at the same time aging of those structures and member deterioration are often reported. Therefore, actions like implement of new materials and strengthening techniques become essential to combat this problem. The application of carbon fibre reinforced polymer (CFRP) with concrete structures has been widely reported whereas researches related to strengthening of steel structures using fibre reinforced polymer (FRP) have been limited. The main objective of this study is to experimentally investigate the suitability of CFRP to strengthening of CFST members under flexure. There were three wrapping schemes such as Full wrapping at the bottom (fibre bonded throughout entire length of beam), U-wrapping (fibre bonded at the bottom throughout entire length and extended upto neutral axis) and Partial wrapping (fibre bonded in between loading points at the bottom) introduced. Beams strengthened by U-wrapping exhibited more enhancements in moment carrying capacity and stiffness compared to the beams strengthened by other wrapping schemes. The beams of partial wrapping exhibited delamination of fibre and were failed even before attaining the ultimate load of control beam. The test results showed that the presence of CFRP in the outer limits was significantly enhanced the moment carrying capacity and stiffness of the beam. Also, a non linear finite element model was developed using the software ANSYS 12.0 to validate the analytical results such as load-deformation and the corresponding failure modes.

Reliability Tests for BLDC Motors Used in Green-Cars (그린카 BLDC 모터의 신뢰성 시험)

  • Yoo, Ki-Hoon;Park, Boo-Hee;Kim, Ki-Tae;Kim, Gi-Young;Kim, Dal-Seok;Jang, Joong-Soon;Hahn, Chang-Su;Cho, Han-Sam
    • Journal of Applied Reliability
    • /
    • v.11 no.1
    • /
    • pp.97-110
    • /
    • 2011
  • BLDC(Brushless Direct Current) motor is a powerful device to control the automotive electronic components used in green cars such as HEV/EVs(Hybrid Electric Vehicle and Electric Vehicle). This study is to propose reliability test items derived through pretesting, suitability analysis abd classification of previous BLDC motor tests. For environmental stress tests are determined by analysing environmental conditions and relevant failure mechanisms induced by climate loads, mechanical loads, chemical loads, etc. ATL and HALT are also considered for life testing and screening.

A Study on Dynamic Characteristic for the Bi-modal Tram with All-Wheel-Steering System (전차륜 조향 장치를 장착한 굴절궤도 차량의 주행특성에 관한 연구)

  • Lee, Soo-Ho;Moon, Kyung-Ho;Jeon, Young-Ho;Park, Tae-Won;Lee, Jung-Shik;Kim, Duk-Gie
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.99-108
    • /
    • 2007
  • The bi-modal tram guided by the magnetic guidance system has two car-bodies and three axles. Each axle of the vehicle has an independent suspension to lower the floor of the car and improve ride quality. The turning radius of the vehicle may increase as a consequence of the long wheel base. Therefore, the vehicle is equipped with the All-Wheel-Steering(AWS) system for safe driving on a curved road. Front and rear axles should be steered in opposite directions, which means a negative mode, to minimize the turning radius. On the other hand, they also should be steered in the same direction, which means a positive mode, for the stopping mode. Moreover, only the front axle is steered for stability of the vehicle upon high-speed driving. In summary, steering angles and directions of the each axle should be changed according to the driving environment and steering mode. This paper proposes an appropriate AWS control algorithm for stable driving of the bi-modal tram. Furthermore, a multi-body model of the vehicle is simulated to verify the suitability of the algorithm. This model can also analyze the different dynamic characteristics between 2WS and AWS.

  • PDF

Development of the Standard Size Dimensions and Reference Sizes for Improving Size Suitability of Gloves (장갑치수적합성 향상을 위한 기본치수 및 참고치수 설정)

  • Kim, Eun-Kyong
    • Fashion & Textile Research Journal
    • /
    • v.10 no.6
    • /
    • pp.966-978
    • /
    • 2008
  • The aim of this study was to provide size intervals in hand requisite in design of gloves. In this study, a survey was administered to gather information about glove manufacturers' sizing systems. In addition, KS glove standards' size dimensions were analyzed. As well, the ISO hand sizing system was also studied. Based on all the analyses' results, a new glove size intervals were composed. The size comprised the control dimensions of hand length and hand circumference. The size interval was 8mm in hand length and 13mm in hand circumference. The size range was established by making the coverage above 80%. The coverage of the new size interval system for an adult's hand was 86.4% and 13 sizes were suggested. The coverage of the male size system was 86.0% and 10 sizes were suggested. The coverage of the female size system was 87.6% and 8 sizes were suggested. For the unfitted gloves, size ranges based on hand length and hand circumference were developed. For the adults group, S, M, L, and XL were suggested and the coverage of the new size range was 78.8%. For the male group, S, M, and L were suggested and the coverage was 82.3%. For the female group, S, M, and L were also suggested and the coverage was 81.3%.

Safety Evaluation of Non-refillable Butane Can Equipped with Relief Valve for Prevention of Explosion (안전밸브가 장착된 휴대용 부탄캔에 대한 안전성 평가 연구)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.212-217
    • /
    • 2008
  • This study carried out the safety evaluation of non-refillable butane can for portable gas range equipped with relief valve for prevention of explosion. The can is heated by electric heater at the real using condition and the extreme condition after installing at a portable gas range for checking the operating pressure and the evaluating suitability of releasing flux. And the possibility of fire or explosion was tested when the gas was released from the relief valve at the real condition. As a result of this safety evaluation test, a non-refillable butane can with relief valve prevents the can from exploding by control of internal pressure.

A Study on the Dynamic Characteristics of the Bi-modal Tram with All-Wheel-Steering System (전차륜 조향 장치를 장착한 굴절궤도 차량의 주행특성에 관한 연구)

  • Lee, Soo-Ho;Moon, Kyung-Ho;Jeon, Young-Ho;Lee, Jung-Shik;Kim, Duk-Gie;Park, Tae-Won
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.4
    • /
    • pp.444-450
    • /
    • 2007
  • The bi-modal tram guided by the magnetic guidance system has two car-bodies and three axles. Each axle of the vehicle has an independent suspension to lower the floor of the car and improve ride quality. The turning radius of the vehicle may increase as a consequence of the long wheel base. Therefore, the vehicle is equipped with the All-Wheel-Steering(AWS) system for safe driving on a curved road. Front and rear axles should be steered in opposite directions, which means a negative mode, to minimize the turning radius. On the other hand, they also should be steered in the same direction, which means a positive mode, for the stopping mode. Moreover, only the front axle is steered for stability of the vehicle upon high-speed driving. In summary, steering angles and directions of the each axle should be changed according to the driving environment and steering mode. This paper proposes an appropriate AWS control algorithm for stable driving of the bi-modal tram. Furthermore, a multi-body model of the vehicle is simulated to verify the suitability of the algorithm. This model can also analyze the different dynamic characteristics between 2WS and AWS.

Synthesis and Evaluation of 2-[123I]iodoemodin for a Potential Breast Cancer Imaging Agent

  • Park, Jeong-Hoon;Kim, Sang-Wook;Yang, Seung-Dae;Hur, Min-Goo;Chun, Kwon-Soo;Yu, Kook-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.595-598
    • /
    • 2008
  • Emodin (3-methyl-1,6,8-trihydroxyanthraquinone) is a natural chemotherapeutic compound with diverse biological properties including an antitumor activity. Emodin, a specific inhibitor of the protein tyrosine kinase, has a number of cellular targets in related to it. Its inhibition activity affects the mammalian cell cycle regulation in specific oncogene. Practically, it has been proven to inhibit HER-2/neu tyrosine kinase expressing breast cancer cells as an anticancer agent. 2-[123I]iodoemodin has been synthesized and evaluated human breast cancer cells (MDA-MB-231, MCF-7, fibroblast as a control) which express basal levels of HER-2/neu tyrosine kinase to investigate its suitability as a breast cancer imaging agent and 2-iodoemodin has been synthesized as a standard compound. The radiochemical yield of the 2-[123I]iodoemodin was about 72% and its radiochemical purity was over 97% after purification. The radioactivity of the 2-[123I]iodoemodin was increased in a time dependent manner in both cell lines and the ratio of MDA-MB-231 and MCF7 to fibroblast was 2.9 and 1.7, respectively.