• Title/Summary/Keyword: control leakage

Search Result 932, Processing Time 0.025 seconds

The Effect of Composition and Security Activities for Information Security Architecture on Information Asset Protection and Organizational Performance (정보보호 아키텍처 구성과 보안활동이 정보자산보호 및 조직성과에 미치는 영향)

  • Jeong, Gu-Heon;Yi, Dong-Wook;Jeong, Seung-Ryul
    • The KIPS Transactions:PartD
    • /
    • v.17D no.3
    • /
    • pp.223-232
    • /
    • 2010
  • This study was carried out for the purpose of inquiring into the effect of composition and security activities for information security architecture on information asset protection and organizational performance in terms of general information security. This study made a survey on 300 workers in the government, public institutions and private companies, which it showed that management factors of risk identification and risk analysis, in general, have an usefulness to composition and security activities for information security architecture to prevent inside information leakage. And the understanding and training factors of IT architecture and its component were rejected, requiring the limited composition and security activities for information security architecture. In other words, from the reality, which most institutions and organizations are introducing and operating the information security architecture, and restrictively carrying out the training in this, the training for a new understanding of architecture and its component as an independent variable made so much importance, or it did not greatly contribute to the control or management activities for information security as the generalized process, but strict security activities through the generalization of risk identification and risk analysis management had a so much big effect on the significant organizational performance.

Review of Unplanned Release at Foreign Nuclear Power Plants and Radiological Monitoring at Korean Power Plants (해외원전 비계획적 방출 및 한국의 환경감시 현황 분석)

  • Park, Soo-Chan;Ham, Baknoon;Kwon, Jang-Soon;Cho, Dong-Keun;Jeong, Jihye;Kwon, Man Jae
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.4
    • /
    • pp.1-15
    • /
    • 2018
  • Despite of safety issues related to radiological hazards, 31 countries around the world are operating more than 450 nuclear power plants (NPPs). To operate NPPs safely, safety regulations from radiation protection organizations were developed and adopted in many countries. However, many cases of radionuclide releases at foreign NPPs have been reported. Almost all commercial NPPs routinely release radioactive materials to the surrounding environments as liquid and gas phases under control. These releases are called 'planned releases' which are planned, regularly monitored, and well documented. Meanwhile, the releases focused in this review, called 'unplanned releases', are neither planned nor monitored by regulatory and/or protection organizations. NPPs are generally composed of various structures, systems and components (SSCs) for safety. Among them, the SSCs near reactors are closely related to safety of NPPs, and typically fabricated to comply with stringent requirements. However, some non-safety related SSCs such as underground pipes may be constructed only according to commercial standards, causing the leakage of radioactive fluids usually containing tritium ($^3H$). This paper discusses SSCs of NPPs and introduces several cases of unplanned releases at foreign NPPs. The current regulation on the environmental radiological surveillance and assessment around the NPPs in South Korea are also examined.

Successful Angiographic Embolization of Superficial Circumflex Iliac Artery Rupture Caused by Blunt Abdominal Trauma: A Case Report (복부 둔상에 의한 얕은엉덩휘돌이동맥 파열의 혈관조영색전술을 통한 성공적인 치료: 증례보고)

  • Lee, Sang Bong;Park, Sung Jin;Yeo, Kwang Hee;Kim, Ho Hyun;Park, Chan-Yong;Kim, Jae Hun;Kim, Chang Wan;Choi, Seon Uoo;Kim, Seon Hee;Hwang, Jung Joo;Cho, Hyun Min
    • Journal of Trauma and Injury
    • /
    • v.28 no.1
    • /
    • pp.39-42
    • /
    • 2015
  • Lat. abdominal wall hematoma with active bleeding is very rare but need prompt bleeding control. We report successful treatment by angiographic embolization of superficial circumflex iliac artery rupture caused by blunt trauma. A 60-year-old woman presented painful, enlarging, lat. abdominal wall mass with ecchymosis caused by blunt abdominal trauma. Contrast leakage of superficial circumflex iliac a. within the lt. ext. oblique m. hematoma was confirmed by abdominal computed tomography. Angiographic embolization was performed successfully. Patient was discharged at 4th day after trauma without complication. Angiographic embolization is important treatment option of lat. abdominal wall hematoma with active bleeding replacing emergency surgery.

  • PDF

Control items modeling methodology to establish core technology management system and successfully operating suggestions for institutional improvement (핵심 기술 관리 체계(CTMS) 수립을 위한 통제 항목 모델링 연구 및 제도적 개선 제안)

  • Shin, Dong-Hyuk;Shim, Mina;Lim, Jong-In
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.1
    • /
    • pp.109-126
    • /
    • 2013
  • Recently the core technology leakage continues to increase. It is critical issue relating to national competitiveness rely on the company's competitiveness as well as both survival and competitiveness of company. So other countries have impyz roved their laws consistently to solve these problems. And recently our country amended the law. In the paper, we will analyze world's various laws and institutions relating industrial core technologies. And this paper will provide the suggestion to settle and to develop our country's industrial core technology's protection by refer to other laws.

Fuzzy Based Failure Mode and Effect Analysis (FMEA) of Hydrogen Production Process Using the Thermococcus Onnurineus NA1 (퍼지기반 해양 미생물 이용 수소 제조 공정의 고장유형 및 영향분석)

  • PARK, SUNG HO;AHN, JUNKEON;KIM, SU HYUN;YOO, YOUNG DON;CHANG, DAEJUN;KANG, SUNGKYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.307-316
    • /
    • 2018
  • In this study, the failure mode and effect analysis (FMEA) of hydrogen production process by using the Thermococcus onnurineus NA1 was conducted and advanced methodology to compensate the weakness of previous FMEA methodology was applied. To bring out more quantitative and precise FMEA result for bio-hydrogen production process, fuzzy logic and potential loss cost estimated from ASPEN Capital Cost Estimator (ACCE) was introduced. Consequently, risk for releasing the flammable gases via internal leakage of steam tube which to control the operating temperature of main reactor was caution status in FMEA result without applying the fuzzification and ACCE. Moreover, probability of the steam tube plugging caused by solid property like medium was still caution status. As to apply the fuzzy logic and potential loss cost estimated from ACCE, a couple of caution status was unexpectedly upgraded to high dangerous status since the potential loss cost of steam tube for main reactor and decrease in product gases are higher than expected.

An Experimental Study on the Mechanical Properties of High Density Concrete Using Magnetite Aggregate (자철광 골재를 이용하는 철근콘크리트의 역학적 특성에 관한 관험적 연구)

  • 반호용;한천구;김을용
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.3
    • /
    • pp.81-88
    • /
    • 1990
  • For the protectioon of radioactive leakage, the quality control of main concrete structure in nuclear power plants is very important. So, this studey is designed to analyze the influence of kind of cement and aggregate on the mechanical properties of high density concrete. Test results of this study are as follows; 1)The slump of magnetite aggregate concrete(MAC) is found half value of nat.ural aggregate concrete (NAC). 2)As the effect of cement, the compressive strength of concrete using moderate heat cement is found higher 5-19 % than that of ordinary portland cement. 3)As the effect of fine aggregate, t.he compressive strength of MAC is found higher than that. of NAC below 340kg/$cm^2$ and lower t.han NAC above 340kg/$cm^2$. 4)As the effect of coarse aggregate, the compressive strength of MAC is found higher 17-22% than that of NAC.

Deuterium Ion Implantation for The Suppression of Defect Generation in Gate Oxide of MOSFET (MOSFET 게이트 산화막내 결함 생성 억제를 위한 효과적인 중수소 이온 주입)

  • Lee, Jae-Sung;Do, Seung-Woo;Lee, Yong-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.7
    • /
    • pp.23-31
    • /
    • 2008
  • Experiment results are presented for gate oxide degradation under the constant voltage stress conditions using MOSFETs with 3-nm-thick gate oxides that are treated by deuterium gas. Two kinds of methods, annealing and implantation, are suggested for the effective deuterium incorporation. Annealing process was rather difficult to control the concentration of deuterium. Because the excess deuterium in gate oxide could be a precursor for the wear-out of gate oxide film, we found annealing process did not show improved characteristics in device reliability, compared to conventional process. However, deuterium implantation at the back-end process was effective method for the deuterated gate oxide. Device parameter variations as well as the gate leakage current depend on the deuterium concentration and are improved by low-energy deuterium implantation, compared to those of conventional process. Especially, we found that PMOSFET experienced the high voltage stress shows a giant isotope effect. This is likely because the reaction between "hot" hole and deuterium is involved in the generation of oxide trap.

Phase Conjugator for Retrodirective Array Antenna Applications (능동 역지향성 배열 안테나용 공액 위상변위기)

  • Chun Joong-Chang;Jeung Deuk-Soo;Lee Byung-Rho;Tack Han-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.134-138
    • /
    • 2005
  • In this paper, we have developed a new type of the microwave phase conjugator for the active retrodirective antenna array. The circuit topology is consisted of a 2-port structure to avoid the complexity of LO and RF signal combination and matching, using the cascade connection of two single-ended mixers. The operating frequencies are 4.0 GHz, 2.01 GHz and 1.99 GHz for LO, RF, and IF, respectively. Conversion loss is measured to be -7 dB and 1-dB compression point 15 dBm with the LO power of 9 dBm. For the most important parameter, the isolation between RE leakage and IF signal is as high as 25 dB.

Toxicogenomics Analysis on Thioacetamide-induced Hepatotoxicity in Mice

  • Lim, Jung-Sun;Jeong, Sun-Young;Hwang, Ji-Yoon;Park, Han-Jin;Cho, Jae-Woo;Yoon, Seok-Joo
    • Molecular & Cellular Toxicology
    • /
    • v.2 no.2
    • /
    • pp.126-133
    • /
    • 2006
  • Thioacetamide (TA) is well known hepatotoxic and hepatocarcinogenic agent. TA also diminishes the contents of hepatic cytochrome P450 and inhibits the enzyme activity of the hepatic mixed function oxidases. TA metabolite, thioacetamide-s-oxide, is further transformed into a still unknown highly reactive metabolite that binds to macromolecules. In this study, we focused on TA-induced gene expression at hepatotoxic dose. Mice were exposed to two levels (5 mg/kg or 50 mg/kg i.p.) of TA, sampled at 6 or 24 h, and hepatic gene expression levels were determined to evaluate dose and time dependent changes. We evaluated hepatotoxicity by serum AST and ALT level and histopathological observation. Mean serum activities of the liver leakage enzymes, AST and ALT, were slightly increased compare to control. H & E and PAS evaluation of stained liver sections revealed TA-associated histopathological finding in mice. Centrilobular eosinophilic degeneration was observed at high dose-treated mice group. Hepatic gene expression was analyzed by QT clustering. Clustering of high dose-treated samples with TA-suggests that gene expressional changes could be associated from toxicity as measured by traditional biomarkers in this acute study.

An Investigationi into the Dynamic Characteristics of Turbine and Gear Motor Type Flowmeters (터빈형과 기어모터형 유량계의 동특성 검토)

  • 예용택
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.83-89
    • /
    • 2000
  • In hydraulic control system turbine and gear motor type flowmeters are widely used to measure the flow rate under steady flow conditions. With the recent growth of interest in the measurement of instantaneous values of unsteady flow rate the test of the transient response of these flowmeters are in some significance. however an unsteady flow rate mea-surment and its calibration method with a fast response and a high accuracy have not beendeveloped. In this research particularly the dynamic characteristics of turbine and gear motor type flowmeters are investigated experimentally and simple mathematical models are proposed. The measured flow rate waveforms are compared with those by remote instan-taneous flow rate measurement method(RIFM) which has been developed by author and used for calibration As the result of frequency response test gain and phase between the measured flow rate waveforms by turbine type flowmeter and those estimated by RIFM are in good agreement up to 70Hz For the gear motor type flowmeter th simulated results by a math-ematical model proposed here agree well with the experiment nearly up to 100Hz. Also it if sound that the pressure drop across the flowmeter is increased in proportion to the frequency of the flow rate variation in a high frequency region of more than 100Hz. It can be explained that the dealy of gear motor type flowmeter in high frequency regionis mainly attributed to a first order delay consisting of the inertia of gears and internal leakage of the gear motor.

  • PDF