• Title/Summary/Keyword: contrast reduction

Search Result 667, Processing Time 0.024 seconds

A Study on the Management Methods of the Ship Infrared Signature (함정 적외선 신호의 관리방법 연구)

  • Cho, Yong-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.3
    • /
    • pp.182-189
    • /
    • 2013
  • In the development process of new naval ships, it is necessary to make the effort of the signature management and reduction of ship infrared(IR) signature to increase the ship survivability(susceptibility). So far the ship's contrast radiant intensity is used as a ship IR signature design criteria during the naval ship design stages. However, nowaday it is in a state of disorder at the basic design stage because of the lack of any related studies and methods. In this study, the IR signature management methods for improving the signature reduction and ship survivability are suggested by the comparison analysis of the advantages and disadvantages of signature management techniques. And also the criteria for the ship signature management are suggested when considering the infrared signature measuring assets and sea trial environments of the Korean peninsula.

Luminance enhancement in single image dehazing

  • Bui, Minh-Trung;Kim, Won-Ha
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.322-324
    • /
    • 2013
  • Haze is an extreme reason of the reduction of contrast when capturing image in the outdoor. Recently, there are several single image dehazing techniques, but they are not robust in dynamic variations of natural environment caused by the thickness, coverage of haze and appearance of sunlight. In this paper, we propose an effective and robust method to enhance luminance for image dehazing depending on histogram analysis. Compare with conventional methods, our proposal have better performance in term of contrast, and computation time.

  • PDF

Histogram-based luminance enhancement for image dehazing

  • Bui, Minh-Trung;Kim, Won-Ha
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2012.07a
    • /
    • pp.16-18
    • /
    • 2012
  • Haze is an extreme reason of the reduction of contrast when capturing image in the outdoor. Recently, there are several single image dehazing techniques, but they are not robust in dynamic variations of natural environment caused by the thickness, coverage of haze and appearance of sunlight. In this paper, we propose an effective and robust method to enhance luminance for image dehazing depending on histogram analysis. Compare with conventional methods, our proposal have better performance in term of contrast, and computation time.

  • PDF

Feasibility Study of Non Local Means Noise Reduction Algorithm with Improved Time Resolution in Light Microscopic Image (광학 현미경 영상 기반 시간 분해능이 향상된 비지역적 평균 노이즈 제거 알고리즘 가능성 연구)

  • Lee, Youngjin;Kim, Ji-Youn
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.623-628
    • /
    • 2019
  • The aim of this study was to design fast non local means (FNLM) noise reduction algorithm and to confirm its application feasibility in light microscopic image. For that aim, we acquired mouse first molar image and compared between previous widely used noise reduction algorithm and our proposed FNLM algorithm in acquired light microscopic image. Contrast to noise ratio, coefficient of variation, and no reference-based evaluation parameter such as natural image quality evaluator (NIQE) and blind/referenceless image spatial quality evaluator (BRISQUE) were used in this study. According to the result, our proposed FNLM noise reduction algorithm can achieve excellent result in all evaluation parameters. In particular, it was confirmed that the NIQE and BRISQUE evaluation parameters for analyzing the overall morphologcal image of the tooth were 1.14 and 1.12 times better than the original image, respectively. In conclusion, we demonstrated the usefulness and feasibility of FNLM noise reduction algorithm in light microscopic image of small animal tooth.

Selective Reduction of Carbonyl and Epoxy Compounds Using Aluminum, Boron and Other Metal Reagents. Comparison of Reducing Characteristics between the Meerwein-Ponndorf-Verley Type Reduction and Metal Complex Hydrides Reduction: A Review

  • Cha, Jin-Soon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2162-2190
    • /
    • 2007
  • The newly-developed Meerwein-Ponndorf-Verley (MVP) type reagents using aluminum, boron and other metals for reduction of organic functional groups such as carbonyl and epoxy compounds have been surveyed. highlighted and reviewed in this account are the appearance of new MPV type reagents and their application to the selective reduction of organic functions. Finally, this account emphasizes the distinct contrast in the reducing characteristics existed between metal hydride reagents and MPV reagents, and compares their usefulness in organic synthesis.

Adaptive Retinex Algorithm using Skewness for Contrast Enhancement (대조비 개선을 위한 비대칭도 특성을 이용한 적응적인 레티넥스 방식)

  • Oh, Jong Geun;Hong, Min-cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.77-83
    • /
    • 2016
  • This paper presents an adaptive retinex algorithm using skewness for contrast enhancement of color images. In order to estimate the degree of low contrast of an image, skewness of luminance of an observed image is used to define a parameter, and a non-linear function is proposed to compensate the reflectance using the parameter and estimated reflectance. In addition, determination of gain and offset of the non-linear function is addressed using statistics of the estimated reflectance. The relation between an observed luminance and the compensated luminance is used to compensate color components with the reduction of computational cost. The experimental results show that the proposed algorithm has the capability to effectively improve the contrast without color distortion.

Four Segmentalized CBD Method Using Maximum Contrast Value to Improve Detection in the Presence of Reverberation (최대 컨트라스트 값을 이용한 4분할 CBD의 잔향 감소기법)

  • Choi, Jun-Hyeok;Yoon, Kyung-Sik;Lee, Soo-Hyung;Kwon, Bum-Soo;Lee, Kyun-Kyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.761-767
    • /
    • 2009
  • The detection of target echoes in a sonar image is usually difficult since reverberation is originated by the returns reflected around the boundary and volumes. Under the scenario of the target presence around the reverberation, the detection performance of existing algorithms is degraded. Since they have a similar statistical features. But proposed detector gives improvement existing algorithms Under this scenario. In this paper, 4 segmentation contrast box algorithm using maximum contrast value is proposed based on statistical segmentation, which gives better detection performance in the sense of reducing false alarms. The simulations validate the effectiveness of the proposed algorithm.

Low-dose Intravenous N-acetylcysteine for the Prevention of Contrast-Induced Nephropathy in Emergency Patients Undergoing Computed Tomography (전산화단층촬영을 시행받는 응급환자에서 조영제 유도 신독성 예방을 위한 저용량 아세틸시스테인 정맥투여)

  • Lee, Tae Wan;Kim, Ji-Hoon;Choi, Seung Pil
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.2
    • /
    • pp.122-130
    • /
    • 2017
  • Purpose: To evaluate the effects of low-dose intravenous N-acetylcysteine on the prevention of contrast-induced nephropathy (CIN) in patients undergoing computed tomography (CT). Methods: All patients presenting to our emergency department and undergoing CT with intravenous contrast media between August 2014 and April 2016 were retrospectively enrolled. We included hospitalized patients with renal dysfunction [estimated glomerular filtration rate (GFR) between 30 and $89mL/min/1.73m^2$]. A 600-mg injection of N-acetylcysteine was given to patients once before and once immediately after CT, depending on the preference of physician. The primary outcome was CIN defined as an increase in creatinine level of ${\geq}25%$ or ${\geq}0.5mg/dL$ from the baseline within 48 to 72 hours after CT. A trained person blindly reviewed all medical records. Results: Of the 1903 admitted patients, CIN occurred in 9.8% of patients who received 1200 mg intravenous N-acetylcysteine (24/244) and 6.8% of patients who did not (113/1659, p=0.090). In a multivariable regression analysis, N-acetylcystine was not relevant to the prevention of CIN (odds ratio=1.42 [95% CI, 0.90-2.26]). Even in the stratified analysis using the propensity score matching, N-acetylcysteine was irrelevant (GFR 30-59: odds ratio=1.06 [95% CI, 0.43-2.60]; GFR 60-89: odds ratio=1.76 [95% CI, 0.75-4.14]). After adjustment, crystalloids were significantly associated with the reduction in CIN compared with dextrose water (odds ratio=0.60 [95% CI, 0.37-0.97]). Conclusion: No effect was found when low-dose intravenous N-acetylcysteine was used to prevent CIN. However, there seems to be an association between crystalloids and reduction in CIN.

Poly(3,4-ethylenedioxythiophene) Electrodes Doped with Anionic Metalloporphyrins

  • 송의환;여인형;백운기
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.11
    • /
    • pp.1303-1308
    • /
    • 1999
  • Conducting poly(3,4-ethylenedioxythiophene) (PEDT) films with metalloporphyrins incorporated as the counter ions were prepared by electropolymerization of the monomer in the presence of metal-tetra(sulfonatophenyl) porphyrin anions. Cathodic reduction of oxygen on the resulting conducting polymer films was studied. The overpotential for O2 reduction on electrodes with cobalt-porphyrin complex was significantly smaller in acidic solutions than on gold. In basic solutions, the overpotential at low current densities was close to those on platinum and gold. Polymer electrode with Co-complex yielded higher limiting currents than with Fe-complex, although the Co-complex polymer electrode was a poorer electrocatalyst for O2 reduction in the activation range of potential than the Fe counterpart. From the rotating ring-disk electrode experiments, oxygen reduction was shown to proceed through either a 4-electron pathway or a 2-electron pathway. In contrast to the polypyr-role-based electrodes, the PEDT-based metalloporphyrin electrodes were stable with wider potential windows, including the oxygen reduction potential. Their electrocatalytic properties were maintained at temperatures up to 80℃ in KOH solutions.

Dual-Slope Ramp Reset Waveform to Improve Dark Room Contrast Ratio in AC PDPs

  • Lim, Jae-Kwnag;Cho, Byung-Gwon;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.639-642
    • /
    • 2005
  • A new dual-slope ramp (DSR) reset waveform is proposed to improve the dark room contrast ratio in AC-PDPs. The proposed reset waveform has two different voltage slopes during a ramp-up period. The first voltage slope is lower than the conventional ramp voltage slope, causing a reduction in the background luminance, whereas the second voltage slope is higher than the conventional ramp voltage slope, causing an increase in the background luminance. Thus, a bias voltage is also applied during the second voltage-slope period to adjust the background luminance and address discharge characteristics. As a result, the proposed dual-slope reset waveform can lower the background luminance, thereby improving the high dark room contrast ratio of an AC-PDP without reducing the address voltage margin

  • PDF