• Title/Summary/Keyword: continuous wave

Search Result 788, Processing Time 0.029 seconds

Intraoperative Neurophysiologic Monitoring and Functional Outcome in Cerebellopontine Angle Tumor Surgery (소뇌-교각종양 수술시 수술 중 전기생리학적 신경감시에 따른 수술 후 기능적 결과)

  • Lee, Sang Koo;Park, Kwan;Park, Ik Seong;Seo, Dae Won;Uhm, Dong Ok;Nam, Do-Hyun;Lee, Jung-Il;Kim, Jong Soo;Hong, Seung Chyul;Shin, Hyung Jin;Eoh, Whan;Kim, Jong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.778-785
    • /
    • 2000
  • Objectives : Intraoperative neurophysiologic monitoring(INM) is a well known useful method to reduce intraoperative neurological complications during neurosurgical procedures. Furthermore, INM is required in most cerebellopontine angle(CPA) surgery because cranial nerves or brain stem injuries can result in serious complications. Object of this study is to the correlation between the changes of intraoperative monitoring modalities during cerebellopontine angle tumor surgery and post-operative functional outcomes in auditory and facial functions. Material and Methods : Fifty-seven patients who underwent intraoperative neurophysiologic monitoring during CPA tumor surgery were retrospectively reviewed. Their lesions were as follows ; vestibular schwannomas in 42, other cranial nerve schwannomas in seven, meningiomas in five and cysts in three cases. Pre- and postoperative audiologic examinations and facial nerve function tests were performed in all patients. Intraoperative neurophysiologic monitoring modalities includes brainstem auditory evoked potentials(BAEP) and facial electromyographies(EMG). We compared the events of INM during CPA tumor surgeries with the outcomes of auditory and facial nerve functions. Results : The subjects who had abnormal changes during CPA tumor surgery were twenty cases with BAEP changes and facial EMG changes in twenty one cases. The changes of intraoperative neurophysiologic monitoring did not always result in poor functional outcomes. However, most predictable intraoperative monitoring changes were wave III-V complex losses in BAEP and continuous neurotonic activities in facial EMG. Conclusion : These results indicate that intraoperative neurophysiologic monitoring in CPA tumor surgery usually provide predictive value for postoperative functional outcomes.

  • PDF

COMPARISON OF BOND STRENGTH OF A FIBER POST CEMENTED WITH VARIOUS RESIN CEMENTS (다양한 레진시멘트로 합착한 섬유포스트의 결합강도 비교)

  • Lee, Hyun-A;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.499-506
    • /
    • 2008
  • The purpose of this study was to compare the push-out strength of a fiber post cemented with various resin cements. Newly extracted 36 human mandibular premolars which had single root canal were selected and their crown portions were removed. The root canal was instrumented using $PROTAPER^{TM}$ system and obturated using continuous wave technique. In each root, a 9-mm deep post space was prepared. #2 translucent fiber post (DT Light post, Bisco Inc., Schaumburg, IL, U.S.A.) was cemented using injection technique with Uni-dose needle tip (Bisco) and six different resin cements. The tested resin cements were Duo-Link (Bisco Inc., Schaumburg, IL, U.S.A.), Variolink II (Ivoclar-Vivadent AG, Schann, Liechtenstein), Panavia F (Kuraray Medical Inc., Okayama, Japan), Multilink Automix (Ivoclar-Vivadent AG, Schann, Liechtenstein), RelyX Unicem (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and Maxcem (Kerr Co., CA, U.S.A.). After storage in distilled water for 24 hours, each root was transversally sectioned into approximately 1-mm thick sections. This procedure resulted in 6 serial sections per root. Push-out test wasperformed using a universal testing machine (EZ Test, Shimadzu Co.) with a crosshead speed of 1 mm/min. The data were analyzed with one-way ANOVA and Tukey HSD (p=0.05). The push-out strength of the groups which cemented fiber post with Panavia F and Multilink Automix were lower than those of the other groups. But, there were no statistically significant difference among groups at a probability level of 0.05.

A Study on the Monitoring Method of Ship Hull and Propeller Performance by Operating Ship (선체 및 프로펠러 성능 모니터링 방법 실선 적용을 통한 고찰)

  • KIM, Dong-Hyun;JUNG, Bong-Kyu;HAN, Seung-Jae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • This study analyzes the results of applying the ISO19030 (hull and propeller performance monitoring method) standard to an actual 178 k bulk vessel. Recently, there have been many attempts to apply various energy reduction solutions to vessels to continuously strengthen GHG reduction regulations and secure maritime competitiveness. However, it is not easy to quantitatively analyze the performance of a ship. To resolve these problems, shipping companies, marine paint companies, ship owners, and transportation associations have appointed specialists and standardized the ISO19030 (standard of hull and propeller performance monitoring method) guidelines in 2016 after three years of continuous review. The ISO19030 standard provides methods to monitor hull and propeller performance quantitatively through standardized procedures, thus allowing ship managers to arrive at informed decisions for hull and propeller maintenance, and to evaluate energy-saving solutions and ship-maintenance efficiency. The ISO19030 standard provides a method of analyzing the ship's own performance by collecting the ship's operation and agency data and correcting its environmental and operating factors. In this paper, we apply the ISO19030 standard to three actual ships and propose the ISO19030 application result and the improvement point of the current ISO19030 standard.

The Next Wave in Display Innovation

  • Webster, Steven C.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.4-4
    • /
    • 2008
  • The progress in flat panel displays over the last two decades has been astonishing. In just 20 years, the LCD-TV grew up from a 2-inch curiosity, to an industry that will sell about 120 million flat panel TV's this year, with viewing area up to 4000 times larger. That success is based on continuous innovation, especially in manufacturing processes. For the next decade to bring another doubling of the business, progress will need to continue in four major areas: Human factors, ecological impact, visual quality, and of course continued drive towards affordability. This talk will detail the technology advances that can allow this industry to meet those challenges. Human factors. Today, we adapt our lifestyle to our technology. People organize their offices, and their homes, around displays. We pass around mobile phones to share images, rather than experiencing them as a group. Billions of newspapers continue to be sold daily. Advances in flexible displays can lead to large portable displays. "New era projection" includes the handheld Pico Projectors that are already on the market, and will ultimately appear integrated in mobile phones the same way cameras do today. "Eco" impact. Today TV's are one of the top energy consumers in a U.S. home, and the fastest growing. Watching a large flat panel TV can cost twice as much as running a large refrigerator. With today's concern about energy consumption, regulations are starting to emerge worldwide to limit TV electrical use. Fortunately, good solutions exist in using light management films to eliminate bulbs, saving power without increasing cost. Going forward, LED backlights will drive another step downward. OLED displays might be the ultimate solution. Visual quality. The color of an LCD-TV is still often considered inferior to a far less expensive CRT. And almost all displays suffer from representing a three-dimensional world on a two dimensional surface. The technology to improve color is available today, and will likely move from premium sets into the mainstream as costs come down. 3D is now arriving in movie theaters worldwide, and that will drive up the demand for similar realistic images in home theaters. And the technology is emerging today for 3D representation to move beyond specialized applications into everyday use, on screens large and small. Affordability. The world takes cost-down miracles for granted in consumer electronics. Each of these other advances will be balanced with a drive for affordability, especially as the market grows in emerging countries. The other three challenges must be met without increasing cost. Putting this all together, the next few years will emphasize "eco friendly" designs, and enhanced images such as 3D. By 2013 we will start to see serious penetration by emissive technologies (OLED, high efficiency plasma, or other), with the "ultimate display" likely not in the market for a decade. Lots of opportunities for innovation remain ahead of us.

  • PDF

Study on Fiber Laser Annealing of p-a-Si:H Deposition Layer for the Fabrication of Interdigitated Back Contact Solar Cells (IBC형 태양전지 제작을 위한 p-a-Si:H 증착층의 파이버 레이저 가공에 관한 연구)

  • Kim, Sung-Chul;Lee, Young-Seok;Han, Kyu-Min;Moon, In-Yong;Kwon, Tae-Young;Kyung, Do-Hyun;Kim, Young-Kuk;Heo, Jong-Kyu;Yoon, Ki-Chan;Yi, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.430-430
    • /
    • 2008
  • Using multi plasma enhanced chemical vapor deposition system (Multi-PECVD), p-a-Si:H deposition layer as a $p^+$ region which was annealed by laser (Q-switched fiber laser, $\lambda$ = 1064 nm) on an n-type single crystalline Si (100) plane circle wafer was prepared as new doping method for single crystalline interdigitated back contact (IBC) solar cells. As lots of earlier studies implemented, most cases dealt with the excimer (excited dimer) laserannealing or crystallization of boron with the ultraviolet wavelength range and $10^{-9}$ sec pulse duration. In this study, the Q-switched fiber laser which has higher power, longer wavelength of infrared range ($\lambda$ = 1064 nm) and longer pulse duration of $10^{-8}$ sec than excimer laser was introduced for uniformly deposited p-a-Si:H layer to be annealed and to make sheet resistance expectable as an important process for IBC solar cell $p^+$ layer on a polished n-type Si circle wafer. A $525{\mu}m$ thick n-type Si semiconductor circle wafer of (100) plane which was dipped in a buffered hydrofluoric acid solution for 30 seconds was mounted on the Multi-PECVD system for p-a-Si:H deposition layer with the ratio of $SiH_4:H_2:B_2H_6$ = 30:120:30, at $200^{\circ}C$, 50 W power, 0.2 Torr pressure for 20 minutes. 15 mm $\times$ 15 mm size laser cut samples were annealed by fiber laser with different sets of power levels and frequencies. By comparing the results of lifetime measurement and sheet resistance relation, the laser condition set of 50 mm/s of mark speed, 160 kHz of period, 21 % of power level with continuous wave mode of scanner lens showed the features of small difference of lifetime and lowering sheet resistance than before the fiber laser treatment with not much surface damages. Diode level device was made to confirm these experimental results by measuring C-V, I-V characteristics. Uniform and expectable boron doped layer can play an important role to predict the efficiency during the fabricating process of IBC solar cells.

  • PDF

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Recent Fertility and its Policy Implications (최근의 출산력과 정책적 함의)

  • Park, Kyung-Ae
    • Korea journal of population studies
    • /
    • v.30 no.3
    • /
    • pp.137-156
    • /
    • 2007
  • Total fertility rate (TFR) increased from the lowest 1.08 in 2005 to 1.13 in 2006, and a debate is made whether the increase is temporary or continuous as a result of various pro-natal policies. This study intends to explore policy implications revealed in recent fertility change using vital statistics. For this purpose, tempo-adjusted fertility rate by birth order, fertility rate by age of mother and birth order, age-specific fertility for married, and age-specific divorce rate for married are analyzed. The increase of TFR and births for 2006 is largely due to increase of first births at early thirties with slowdown of delayed first marriage and first child birth. The increase of female population (the third wave effect of baby boom) and first marriages of late twenties in 2006 and 2007 would lead to increase of fertility during 2007-2008. But further increase is uncertain because of the decrease trend of marital fertility and increase trend of never-married for twenties. TFRs for first and second births reduced rapidly, while TFRs for third and above births showed no changes, and second births were largely affected by tempo adjustment of fertility. Thus, constructing social environment for first and second births is more effective and necessary than encouraging third births. In addition, social responsibility of child care, child-women health issues due to delayed births, and the need for multi-cultural family support system are discussed.

Treatment of Gingival Irritation Fibroma Using $CO_2$ Laser (이산화탄소 레이저($CO_2$ laser)를 이용한 치은에 발생한 자극성 섬유종의 치료)

  • Choi, Young-Chan;Park, Ju-Hyun;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.2
    • /
    • pp.119-122
    • /
    • 2010
  • Carbondioxide($CO_2$) laser is one of the most widely employed lasers in oral soft tissue surgery because of its excellent affinity for water based soft tissues. It has some inherent advantages such as hemostasis, less postoperative swelling, reduction of bacterial population at surgical site, less need for suturing, less scarring, and less postoperative pain compared to conventional surgical therapies including the use of scalpel, diathermy, cryotherapy and electrosurgery. A 30-years-old male was presented with gingival swelling. Clinical examination revealed a well?defined pedunculated fibrotic mass on the buccal gingiva near right maxillary 1st molar. In radiographic examination, no remarkable abnormality was seen. Excisional biopsy was performed with $CO_2$ laser (continuous wave mode, 4.0W). Histological diagnosis was "Irritation fibroma". $CO_2$ laser has advantages those are suitable for surgical treatment of intraoral lesion. If appropriate training and experience are provided, the dentist would be able to manage intraoral lesions more efficiently and successfully with the use of the $CO_2$ laser.

IN VITRO STUDY ON APICAL SEAL AND SEM MORPHOLOGY IN CANALS FILLED WITH RESIN-BASED ROOT CANAL SEALER AND SELF-ETCHING PRIMER (SELF-ETCHING PRIMER와 레진계 근관 SEALER 사용시 근관벽의 형태와 치근단 근관밀폐에 대한 실험적 연구)

  • Kang, Sam-Hee;Park, Dong-Sung;You, Heyon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.543-549
    • /
    • 2000
  • Gutta-percha와 근관sealer를 사용한 근관 충전은 가장 많이 이용되고 성공률이 높은 방법이지만, 현재 사용되는 모든 근관sealer는 미세누출을 나타낸다. 따라서 더 효과적인 근관 폐쇄를 이루기 위한 재료 및 방법들이 연구되어왔다. 이중 상아질 접착제는 근관 충전재와 함께 사용되어 미세누출을 감소시키지만, 근관 내에 사용하기에 술식이 복잡하고 기술이 요구된다. 본 연구의 목적은 gutta-percha와 레진계 근관 sealer로 충전한 근관에서 self-etching primer를 미리 도포한 경우와 도포하지 않은 경우의 치근단 미세누출을 비교하고, self-etching primer를 도포함에 있어 근관 내에 적용하는 방법에 따른 미세누출을 비교하는 것이다. 또한 근관sealer와 상아질 계면을 주사전자현미경으로 관찰하여, 이 결과를 미세누출과 관련시켜보고자 하였다. 36개의 발거된 사람의 단근치에서 치관부를 절단, 제거하고 ProFile로 근관 형성한 후, 무작위로 선택하여 4개의 군으로 분류하였다. 1군에서는 주사기와 30게이지 주사 바늘로 self-etching primer를 근관 내에 적용하였고, 2군에서는 self-etching primer를 paper point에 적셔 근관 내에 적용하였다. 3군에서는 self-etching primer를 적용하지 않았다. 1, 2, 3군의 치아를 gutta-percha와 AH26 sealer를 사용하여 continuous wave 충전법으로 충전한 후 치근단공 주위 3mm를 제외한 치근변에 nail polish를 2회 도포하였고, 4군(음성 대조군)은 치근면 전체에 도포하였다. 1군과 2군에서 각각 2개의 치아는 주사전자현미경적 관찰을 위해 준비하였다. 모든 치아를 Methylene Blue 수용액에 48시간동안 침적, 수세한 후 치아 장축에 평행하게 양분하여 10배의 실물확대현미경 하에서 치근단 색소 침투를 관찰하였다. Self-etching primer를 도포한 군과 도포하지 않은 군 사이에는 평균 미세누출량에 유의한 차이가 없었다. 주사 바늘로 적용한 군과 paper point로 적용한 군 사이에도 평균 미세누출량에 유의한 차이가 없었다. 상아질과 근관 sealer계면의 주사전자현미경 관찰 결과 일부분에서 긴밀한 접착 관계를 나타내었고, 다른 부분에서는 간극을 나타내었다.

  • PDF

Extended Target State Vector Estimation using AKF (적응형 칼만 필터를 이용한 확장 표적의 상태벡터 추정 기법)

  • Cho, Doo-Hyun;Choi, Han-Lim;Lee, Jin-Ik;Jeong, Ki-Hwan;Go, Il-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.6
    • /
    • pp.507-515
    • /
    • 2015
  • This paper proposes a filtering method for effective state vector estimation of highly maneuvering target. It is needed to hit the point called 'sweet spot' to increase the kill probability in missile interception. In paper, a filtering method estimates the length of a moving target tracked by a frequency modulated continuous wave (FMCW) radar. High resolution range profiles (HRRPs) is generated from the radar echo signal and then it's integrated into proposed filtering method. To simulate the radar measurement which is close to real, the study on the properties of scattering point of the missile-like target has been conducted with ISAR image for different angle. Also, it is hard to track the target efficiently with existing Kalman filters which has fixed measurement noise covariance matrix R. Therefore the proposed method continuously updates the covariance matrix R with sensor measurements and tracks the target. Numerical simulations on the proposed method shows reliable results under reasonable assumptions on the missile interception scenario.