• Title/Summary/Keyword: continuous vibration

Search Result 446, Processing Time 0.034 seconds

A Study on the Establishment of the Environmental Noise Criteria for Aircraft (항공기 소음 환경 기준 설정을 위한 연구)

  • Kim, Sun-Woo;Jang, Gil-Soo;Lee, Soo-Gab;Song, Min-Jeong;Chang, Se-Myong;Jeon, Ji-Hyun;Ahn, Byung-Og
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.420-430
    • /
    • 2002
  • Rating scales for environmental noise are varied in their calculation procedure. Among them WECPNL (weighted equivalent continuous perceived noise level) is the rating scale for aircraft noise currently being used in domestic and applied only for aircraft noise. However $L_{dn}$ calculated from $L_{eq}$ $L_{eq}$ is used as a rating scale for not only aircraft noise but also environmental noise. Besides, it is easy to calculate and internationally preferred. It is, therefore, not adequate for the evaluation of residents' exposure. Moreover it is very difficult to measure the aircraft noise by WECPNL due to the complicated calculating procedures if automatic measuring system is not used. Accordingly. this study aims to propose alternative evaluation procedure for the aircraft noise. To achieve this purpose, the data measured by automatic measuring system were gathered and calculated with three evaluation procedures : WECPNL $L_{eq}$ and $L_{dn}$, and the results calculated from different methods were compared and analyzed.

The Bias Error due to Windows for the Wigner-Ville Distribution Estimation (위그너-빌 분포함수의 계산시 창문함수의 적용에 의한 바이어스 오차)

  • 박연규;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.80-85
    • /
    • 1995
  • Too see the effects of finite record on the estimation of WVD in practice, a window which has time varying length is examined. Its length increases linearly with time in the first half of the record, and decreases from the center of the record. The bias error due to this window decreases inversely proportionally to the window length as time increases in the first half. In the second half, the bias error increases and the resolution decreases as time increases. The bias error due to the smoothing of WVD, which is obtained by two-dimensional convolution of the true WVD and the smoothing window, which has fixed lengths along time and frequency axes, is derived for arbitrary smoothing window function. In the case of using a Gaussian window as a smoothing window, the bias error is found to be expressed as an infinite summation of differential operators. It is demonstrated that the derived formula is well applicable to the continuous WVD, but when WVD has some discontinuities, it shows the trend of the error. This is a consequence of the assumption of the derivation, that is the continuity of WVD. For windows other than Gaussian window, the derived equation is shown to be well applicable for the prediction of the bias error.

  • PDF

Monitoring of Beam-Column Joint Using Optical Fiber Sensors (광섬유센서를 이용한 Beam-column 조인트의 하중에 따른 변위 계측)

  • 김기수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.595-601
    • /
    • 2003
  • For monitoring of the civil and building structure, optical fiber sensors are very convenient. The fiber sensors are very small and do not disturb the structural properties. They also have several merits such as electro-magnetic immunity, long signal transmission, good accuracy and multiplicity of one sensor line. Strain measurement technologies with fiber optic sensors have been investigated as a part of smart structure. In this paper, we investigated the possibilities of fiber optic sensor application to the monitoring of beam-column joints of structures. We expect that the fiber optic sensors replace electrical strain gauges. The commercial electric strain gauges show good stability und dominate tile strain measurement market. However, they lack durability and long term stability for continuous monitoring of the structures. In order to apply the strain gauges, we only have to attach them to the surfaces of the structures. In this paper, we investigate the possibility of using fiber optic Bragg grating sensors to joint structure. The sensors show nice response to the structural behavior of the joint.

  • PDF

Optimal Transducer Placement Based on Kinetic Energy of the Structural System (구조물의 운동 에너지 원리에 의한 감지기의 최적 위치)

  • Hwang, Chung-Yul;Heo, Gwang-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.2
    • /
    • pp.87-94
    • /
    • 1997
  • This research aims to develop an algorithm of optimal transducer placement using Kinetic Energy of the structural system. The structural vibration response-based health monitoring is considered one of the best for the system which requires a long-term, continuous monitoring. In its experimental modal testing, however, it is difficult to decide on the measurement locations and their number, especially for complex structures, which have a major influence on the quality of the results. In order to minimize the number of sensing operations and optimize the transducer location while maximizing the accuracy of results, this paper discusses about an optimum transducer placement criterion suitable for the identification of structural damage. As a criterion algorithm, it proposes the Kinetic Energy Optimization Technique (EOT), and then addresses the numerical issues which are subsequently applicable to actual experiment where a bridge model is used. By using the experimental data, it compares the EOT with the EIM (Effective Independence Method) which is generally used to optimize the transducer placement for the damage identification and control purposes. The comparison conclusively shows that the EOT algorithm proposed in this paper is preferable when a structure is to be instrumented with fewer sensors.

  • PDF

A response spectrum method for seismic response analysis of structures under multi-support excitations

  • Li, Jian-Hua;Li, Jie
    • Structural Engineering and Mechanics
    • /
    • v.21 no.3
    • /
    • pp.255-273
    • /
    • 2005
  • Based on the random vibration theory, a response spectrum method is developed for seismic response analysis of linear, multi-degree-of-freedom structures under multi-support excitations is developed. Various response quantities, including the mean and variance of the peak response, the response mean frequency, are obtained from proposed combination rules in terms of the mean response spectrum. This method makes it possible to apply the response spectrum to the seismic reliability analysis of structures subjected to multi-support excitations. Considering that the tedious numerical integration is required to compute the spectral parameters and correlation coefficients in above combination rules, this paper further offers simplified procedures for their computation, which enhance dramatically the computational efficiency of the suggested method. The proposed procedure is demonstrated for tow numerical examples: (1) two-span continuous beam; (2) two-tower cabled-stayed bridge by using Monte Carlo simulation (MC). For this purpose, this paper also presents an approach to simulation of ground motions, which can take into account both mean and variation properties of response spectrum. Computed results based on the response spectrum method are in good agreement with Monte Carlo simulation results. And compared with the MSRS method, a well-developed multi-support response spectrum method, the proposed method has an incomparable computational efficiency.

Dynamics of the oscillating moving load acting on the hydroelastic system consisting of the elastic plate, compressible viscous fluid and rigid wall

  • Akbarov, Surkay D.;Ismailov, Meftun I.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.3
    • /
    • pp.403-430
    • /
    • 2016
  • This paper studies the dynamics of the lineal-located time-harmonic moving-with-constant-velocity load which acts on the hydro-elastic system consisting of the elastic plate, compressible viscous fluid - strip and rigid wall. The plane-strain state in the plate is considered and its motion is described by employing the exact equations of elastodynamics but the plane-parallel flow of the fluid is described by the linearized Navier-Stokes equations. It is assumed that the velocity and force vectors of the constituents are continuous on the contact plane between the plate and fluid, and impermeability conditions on the rigid wall are satisfied. Numerical results on the velocity and stress distributions on the interface plane are presented and discussed and the focus is on the influence of the effect caused by the interaction between oscillation and moving of the external load. During these discussions, the corresponding earlier results by the authors are used which were obtained in the cases where, on the system under consideration, only the oscillating or moving load acts. In particular, it is established that the magnitude of the aforementioned interaction depends significantly on the vibration phase of the system.

Expanding the MCS of Refinery Process Compressor through Operating-Speed Balancing at 10,500 rpm (정유공정 압축기의 10,500 rpm 운전속도 밸런싱을 통한 MCS의 확장)

  • Lee, An-Sung;Kim, Byung-Ok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.6
    • /
    • pp.41-46
    • /
    • 2009
  • This paper deals with the operating-speed (high-speed) balancing of a refinery gasoline HDS (hydrodesulfurization) process recycle-gas 8-stages compressor rotor. A low-speed balancing condition of the rotor was measured as maintaining the G2.5 level. But an inspection run of operating-speed balancing condition, using tilting-pad journal bearings of actual use, showed that while it could be continuously-operated safely at a rated speed of 10,500 rpm, the rotor would not be able to run over 11,000 rpm as the vibration increased very sharply, approaching 11,000 rpm. In order to cure that a series of operating-speed balancing, which first calculated balance correction-weights by applying the influence coefficient measured and calculated at 10,500 rpm and then implemented correction works, was carried-out. The final operating-speed balancing results showed that the vibrations at the bearing pedestals represented very good levels of 0.2 mm/s by decreasing to as much as the 1/10 of the original vibrations and particularly, even at a targeted maximum continuous operating speed, MCS, of 11,500 rpm the vibrations represented about 1 mm/s, which is the operating-speed balancing vibration specification of API. Therefore, the expansion of MCS was successfully accomplished through the operating-speed balancing.

Application of the Unstructured Finite Element to Longitudinal Vibration Analysis (종방향 진동해석에 비구조적 유한요소 적용)

  • Kim Chi-Kyung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.39-46
    • /
    • 2006
  • This paper analyzes the continuous Galerkin method for the space-time discretization of wave equation. The method of space-time finite elements enables the simple solution than the usual finite element analysis with discretization in space only. We present a discretization technique in which finite element approximations are used in time and space simultaneously for a relatively large time period called a time slab. The weighted residual process is used to formulate a finite element method for a space-time domain. Instability is caused by a too large time step in successive time steps. A stability problem is described and some investigations for chosen types of rectangular space-time finite elements are carried out. Some numerical examples prove the efficiency of the described method under determined limitations.

Dynamic Modeling of a Novel ATC Mechanism based on 4-bar Linkage (4절링크를 기반으로 하는 신개념 ATC 메커니즘의 동역학 해석)

  • Lee, Sangho;Kim, Jong-Won;Seo, TaeWon;Kim, Jongwon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.4
    • /
    • pp.307-314
    • /
    • 2016
  • Recently, demands on the tapping machine are increased due to the case of a cell phone is changed to metal such as aluminum. The automatic tool changer (ATC) is one of the most important devices for the tapping machine related to the speed and energy consumption of the machine. To reduce the consumed energy and vibration, the dynamic modeling is essential for the ATC. In this paper, inverse dynamic modeling of a novel ATC mechanism is introduced. The proposed ATC mechanism is composed of a double four-bar mechanism with a circular tablet to generate continuous rotation of the tablet. The dynamic modeling is performed based on the Lagrange equation with a modeling for the contact between the four-bar and the tablet. Simulation results for various working conditions are proposed and analyzed for the prototype design. The dynamic modeling can be applied to determine the proper actuator and to reduce the vibration and consumed energy for the ATC machine.

The Present State of Wind Turbine Condition Monitoring System (풍력 터빈 상태 감시 시스템 현황)

  • Clark, Timothy J.;Bauer, Richard F.;Rasmussen, James R.;Jeong, J.H.;Lee, B.J.;Lee, C.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.92-97
    • /
    • 2005
  • The $9 billion US global wind energy market is experiencing dramatic growth with installed generating capacity up 500% from 7,600 MW at the end of 1997 to nearly 39,300 MW at the end of 2003. With an average annual increase approaching 32%, wind is the world's fastest growing energy source on a percentage basis, and its growth is forecast to continue a double-digit pace into the next decade 1. While much of this growth is fueled by government decisions that are favorable to 'green' or renewable Power, it is also fueled by advances in wind turbine technology as evidenced by larger, more sophisticated machines. As a result, wind turbines are becoming more established as an economically viable alternative to fossil-fueled power generation. Today, wind 'farms' - consisting of anywhere from a single turbine to as many as several hundred turbines - are an important component of the world's source of electric energy.

  • PDF