A Study on Hygienic Space Planing of a University Student Restaurant - Focused on the customer space in E University Student Restaurant in Seoul Applying HACCP - (대학 학생 식당의 위생적 공간 계획에 관한 연구 - 서울 E 대학 학생 식당 고객 공간에 HACCP 적용 중심으로 -)

  • Lee, Jong-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.182-189
    • /
    • 2011
  • This research suggests a way of hygienic space planing of the customer space in the university student restaurant of E University in Seoul. For this study. the behavior observation in the restaurant was conducted in order to analyze the sequence of customer behavior related space planing applying HACCP (Hazard Analysis And Critical Control Point). Also the survey was conducted to analyze opinions of customers about hygiene of the space. The results of the analyses of the observation and the survey were similar in terms of hygiene. In conclusion, for hygienic space planing of the customer space in restaurant, the space circulation should be planned according to the hygienic sequence of customer behavior. The spaces in restaurant should be divided into two areas: the clean area and the contaminated area to prevent cross-contamination. The clean area, such as spaces preparing dishes and food including water and table hall where customers eat, should be separated from the contaminated area such as the spaces where waste is handled and where dirty dishes are kept. In order to prevent cross-contamination, hygiene facility to remove contamination should be located before going to the clean area. More specifically, the hygiene facility should be located between a cash counter and a space preparing dishes so that customers can wash their hands before they touch dishes. Space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination is removed in the restaurant.

Source Identification of Heavy Metal Contamination at an Industrial Complex Established Using Construction Wastes (건설폐기물을 성토재로 사용한 산업단지에서의 중금속 오염 원인 규명)

  • JOO, Gwonho;KIM, Kibeum;NAM, Kyoungphile;JUNG, Jae-Woong;Moon, Seheum;CHOI, Yongju
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.1
    • /
    • pp.54-62
    • /
    • 2018
  • This paper is aimed at source tracking of soil heavy metal contamination at a site established by reusing construction wastes. The soil heavy metal concentration at the study site peaked at a depth range of 5-10 m. Column studies were conducted to investigate the possibility of the contamination scenario of infiltration of stormwater carrying heavy metals of ground origin followed by selective heavy metal accumulation at the 5-10 m depth range. Almost all amount of lead, zinc, cadmium, and nickel introduced to the columns each packed with 0-5 m or 5-10 m field soil were accumulated in the column. The very poor heavy metal mobility in spite of the weak association of the heavy metals with the soil (characterized by a sequential extraction procedure) can be attributed to the high pH (10-11) of the construction wastes. From the results, the heavy metal contamination of the subsurface soil by an external heavy metal source was determined to be very unlikely at the study site. The column study applied in the current study is expected to be a useful methodology to present direct evidence of the contaminant source tracking at soil contamination sites.

Evaluation of Groundwater Contamination Potential of Pesticides Using Groundwater Ubiquity Score in Jeju Island Soils (Groundwater Ubiquity Score를 이용한 제주도 토양 특성별 농약의 지하수 오염가능성 평가)

  • Hyun, Hae-Nam;Jang, Gong-Man;Oh, Sang-Sil;Chung, Jong-Bae
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.3
    • /
    • pp.144-153
    • /
    • 2007
  • One of the most recent issues facing the pesticides regulatory process is the assessment of the potential for pesticides to leach through soil and appear in groundwater. Since Jeju island depends on a hydrogeologically vulnerable aquifer system as its principle source of drinking water, it is important to identify which pesticides are the most likely to result in groundwater contamination. The objective of this study was to assess groundwater contamination risk of 21 pesticides (12 insecticides, 6 herbicides and 3 fungicides) in Jeju soils using groundwater ubiquity score (GUS). Considering GUS estimated in 21 representative series of Jeju soils, generally herbicides showed relatively higher leaching potentials and insecticides showed lower leaching potentials. Groundwater contamination risk was higher in the order of bromacil > metolachlor > alachlor > linuron pretilachlor > butachlor for herbicides, carbofuran > ethoprophos > diazinone > dimethoate > penthoate > mecarbam > methidathion > endosulfan > fenitrothion > parathion > chlorpyrifos > terbufos for insecticides, and metalaxyl > chlorothalonil > triadimefon for fungicides. Among the tested pesticides alachlor, metolachlor, bromacil, ethoprophos and carbofuran were classified as the pesticides of very high or high groundwater contamination potential. Although the ranking of the leaching potential was essentially determined on the base of the intrinsic properties of the chemicals and environmental properties, variation of the relative groundwater contamination potentials of each pesticides in different soils were not significant. Therefore, the above ranking of groundwater contamination risk would be applied in most of Jeju soils. To lower the possibility of pesticide contamination of groundwater, the use of those pesticides classified as high or very high leaching potential should be strictly regulated in Jeju Island.

Deposition Characteristics of Atmospheric PCBs by Type of Leaves in Pine Needles (소나무 종별 대기 중 PCBs의 침착특성)

  • Shin Eun Sang;Yeo Hyun-Gu;Cho Ki-Chul;Chun Man-Young
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.46-52
    • /
    • 2006
  • Results for the concentrations of total polychlorinated biphenyls (total PCBs) and the PCB profile with different types of leaves from four coniferous trees (pine needles) at the same sampling site are presented. Concentrations of total PCBs detected in pine needles were very similar among them regardless of their different types of leaves, which means a possibility for bio-monitoring regional contamination of PCBs. Correlation coefficients(r) of PCB congeners between pine needles were very significant (r>0.97, p<0.001), which showed that PCB congener's patterns of each pine needle were similar. Profiles of PCBs detected in pine needles showed correlation with gaseous phase PCBs in air, otherwise not with particle phase PCBs in air. Therefore, it was estimated that dry gaseous deposition was a principal pathway of PCBs accumulation in pine needles. In addition, although we analyse a different types of leaves in pine needles at the same region, they can be used to identify regional contamination patterns of PCBs for larger regions.

The Effect of Saliva in Squamous Cell Carcinoma(SCC) and Thyroid Function Test with Radioimmunoassay (타액이 편평상피세포암(SCC)과 갑상선기능검사에 미치는 영향)

  • Cho, Man Ick;Moon, Ki Choon;Kim, Hea Sook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.269-273
    • /
    • 2004
  • Squamous cell carcinoma(SCC) associated antigen is a subfraction of TA-4, a tumor-associated antigen first described by Kato and Torigoe in 1977. TA-4, obtained from squamous cell carcinoma cancer tissue of the uterine cervix, has been characterized as a glycoprotein with a molecular weight of approximately 45,000 daltons. SCC antigen has been studied in other squamous cell malignancies including lung, esophagus, head and neck, anal canal, and skin. SCC antigen is shed naturally through sweat, saliva and other body fluids. Contamination of specimens, tray, bead dispenser or other accessories with sweat, saliva or aerosols can cause falsely elevated values. To reduce the possibility of contamination, gloves should be worn in all phases of assay preparation, and when handling specimens, accessories or reagents that will be used in SCC and Thyroid function test(TFT).

  • PDF

Quantification of Uncertainty Associated with Environmental Site Assessments and Its Reduction Approaches (부지 오염도 평가시 불확실성 정량화 및 저감방안)

  • Kim, Geonha;Back, JongHwan;Song, Yong-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.1
    • /
    • pp.26-33
    • /
    • 2014
  • Uncertainty associated with a sampling method is very high in evaluating the degree of site contamination; therefore, such uncertainty affects the reliability of precise investigation and remediation verification. In particular, in evaluating a site for a small-sized filling station, underground utilities, such as connection pipes and oil storage tanks, make grid-unit sampling impossible and the resulting increase in uncertainty is inevitable. Accordingly, this study quantified the uncertainty related to the evaluation of the degree of contamination by total petroleum hydrocarbon and by benzene, toluene, ethylene, and xylene. When planning a grid aimed at detecting a hot spot, major factors that influence the increase in uncertainty include grid interval and the size and shape of the hot spot. The current guideline for soil sampling prescribes that the grid interval increase in proportion to the area of the evaluated site, but this heightens the possibility that a hot spot will not be detected. In evaluating a site, therefore, it is crucial to estimate the size and shape of the hot spot in advance and to establish a sampling plan considering a diversity of scenarios.

In-situ Process Monitoring Data from 30-Paired Oxide-Nitride Dielectric Stack Deposition for 3D-NAND Memory Fabrication

  • Min Ho Kim;Hyun Ken Park;Sang Jeen Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.53-58
    • /
    • 2023
  • The storage capacity of 3D-NAND flash memory has been enhanced by the multi-layer dielectrics. The deposition process has become more challenging due to the tight process margin and the demand for accurate process control. To reduce product costs and ensure successful processes, process diagnosis techniques incorporating artificial intelligence (AI) have been adopted in semiconductor manufacturing. Recently there is a growing interest in process diagnosis, and numerous studies have been conducted in this field. For higher model accuracy, various process and sensor data are required, such as optical emission spectroscopy (OES), quadrupole mass spectrometer (QMS), and equipment control state. Among them, OES is usually used for plasma diagnostic. However, OES data can be distorted by viewport contamination, leading to misunderstandings in plasma diagnosis. This issue is particularly emphasized in multi-dielectric deposition processes, such as oxide and nitride (ON) stack. Thus, it is crucial to understand the potential misunderstandings related to OES data distortion due to viewport contamination. This paper explores the potential for misunderstanding OES data due to data distortion in the ON stack process. It suggests the possibility of excessively evaluating process drift through comparisons with a QMS. This understanding can be utilized to develop diagnostic models and identify the effects of viewport contamination in ON stack processes.

  • PDF

A Study on Recycle of Excavated Soil from Ballast Cleaning (철도 도상자갈치기 발생토사의 재활용에 관한 연구)

  • Kim, Young-Chul;Kim, Youn-Sin;Kim, Kyung-Soo;Jeong, Chan-Ill;Lee, Eui-Hak
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1757-1763
    • /
    • 2011
  • In recent years, accordance to industrial development project on railway investment, adverse environmental issues of the investment, such as disputed cases about recycling and usage of Ballast Cleaner excavated soil, have been continuously increasing. It will not only enhance the regulation of soil contamination but take considerable time and cost in future. In this study, we investigated soil contamination and burnability with soil of Chungang Line, Taebaek Line, Chungbuk Line, in order to seize a possibility of recycling Ballast Cleaner excavated soil for the natural materials and substantial heat sources, which are necessary resources for cement manufacturing process. As a result of this study, It is found that Ballast Cleaner excavated soil is satisfied with a standard. The excavated soil contains a lot of cement ingredients and fossil fuel dust incurred from freight transportation, so it is expected to use for ingredients of cement and replacement of heat sources.

  • PDF

동위원소를 이용한 폐금속광산 지역 오염원 추적 연구

  • Yeom Seung-Jun;Lee Pyeong-Gu;Lee In-Gyeong;Lee Uk-Jong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.209-212
    • /
    • 2006
  • Using sulfur sotope analysis of dissolved sulfate in surface water, we have investigated the source of sulfate in order to identify the abandoned metallic mines, which have the potential of heavy metal contamination within watershed. The range of the sulfur isotope values for dissolved sulfate in stream waters (DD-1 and 2) are similar to those of sulfides from the Dunjun mine, which suggests that oxidation of sulfides is the principal source of $SO_4^{2-}$ in these stream waters. Also, heavier sulfur isotopes in waters near Baekjun and Hamchang mines imply the possibility of contamination in waters by these metallic mines.

  • PDF

Automatic Measuring Apparatus for Salt and Dust Contamination (염진해 오손도 자동측정장치)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF