• Title/Summary/Keyword: contamination degree

Search Result 338, Processing Time 0.027 seconds

Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics (치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사)

  • Kim, Seol-Hee
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.472-480
    • /
    • 2017
  • The purpose of this study was to investigate Staphylococcus epidermidis contamination on hands of 20 dental hygienists and 140 equipment surface of 20 dental clinics in a local area, from July to August 2017. The degree of S. epidermidis contamination was measured using a hand plate and a rodac plate and then cultured at $35^{\circ}C$ for 24 hours. Based on hand plate criteria, hand contamination was classified into low, middle, and high groups. Analysis of the variance (ANOVA) of the contamination level of the hand parts of the group surface contamination level of the dental clinic equipment was descriptive statistics after clustering lock count. S. epidermidis contamination was moderate in 55% of the hands of dental hygienists. The area of contamination was 29.45 colony-forming units (CFU) on the palm, followed by the middle finger 7.8 CFU, ring finger 6.4 CFU, and thumb 6 CFU. Medical equipment surface contamination was showed that 3-way handle 4.45 CFU, computer mouse 3.37 CFU, mirror handle 1.60 CFU were higher than other areas. The group with high hand contamination had a high positive correlation with the S. epidermidis contamination of the hand. S. epidermidis contamination level was higher on hands than on the medical equipment surface contamination. Therefore, medical staff should recognize the importance of hand hygiene which should be practiced in the manner suggested by World Health Organization. In addition, the medical team needs to be responsible for performing infection control tasks, implementing infection management guidelines and providing systematic education on infectious disease management.

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF

Classified Fishery Grade Using Analysis of Coastal Environmental Based on Object-Oriented Data Model (객체지향 데이터 모델에 기반한 해양환경 분석에 따른 어장 등급 분류)

  • Lee, Jae-Bong;Lee, Hong-Ro
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.1
    • /
    • pp.40-48
    • /
    • 2005
  • This paper will specify geo-objects and geo-fields of the geo-ecological contamination source and implement the system for evaluating an ocean Environmental contamination based on the spatial statistical analysis. In order to produce the grade of fishery that can evaluate the ocean effect, we will analysis the degree of the spatial correlation by semi-veriogram and predicate the elevation raster of spatial data using ordinary kriging method. This paper is to estimate the grade of fishery contamination region and produce the ratio of the area according to the fishery grade. Therefore, we can contribute to produce fishery grade that evaluates the ocean effect by means of deciding an efficient fishery environment.

  • PDF

Effect of Particle Contamination of Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RE Signal (CD-ROM 드라이브의 대물렌즈 입자오염이 레이저 다이오드 파워와 포토 다이오드 RF 신호에 미치는 영향)

  • Pae, Yang-Il;Lee, Jae-Ho;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.66-71
    • /
    • 2004
  • Airborne contaminant particles are intruded into optical disk drive(ODD) due to the flow caused by disk rotation and can be adhered to objective lens, which causes read/write errors. Such a phenomenon can be a serious problem for high-density storage devices. The purpose of this paper is to understand the effect of particle contamination of objective lens in a CD-ROM drive on laser diode power and photo diode RF signal. The measurements of laser power and readout RF signal were carried out by using a laser power meter and a time interval analyzer, respectively. The parameters for estimating a readout-signal' distortion were its jitter and amplitude. Alumina(Al$_2$O$_3$) particles were used as test dust particles. The results show that the failure for data access happened as the degree of lens contamination was greater than 20%.

A Highly Sensitive Determination of Bulk Cu and Ni in Heavily Boron-doped Silicon Wafers

  • Lee, Sung-Wook;Lee, Sang-Hak;Kim, Young-Hoon;Kim, Ja-Young;Hwang, Don-Ha;Lee, Bo-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.7
    • /
    • pp.2227-2232
    • /
    • 2011
  • The new metrology, Advanced Poly-silicon Ultra-Trace Profiling (APUTP), was developed for measuring bulk Cu and Ni in heavily boron-doped silicon wafers. A Ni recovery yield of 98.8% and a Cu recovery yield of 96.0% were achieved by optimizing the vapor phase etching and the wafer surface scanning conditions, following capture of Cu and Ni by the poly-silicon layer. A lower limit of detection (LOD) than previous techniques could be achieved using the mixture vapor etching method. This method can be used to indicate the amount of Cu and Ni resulting from bulk contamination in heavily boron-doped silicon wafers during wafer manufacturing. It was found that a higher degree of bulk Ni contamination arose during alkaline etching of heavily boron-doped silicon wafers compared with lightly boron-doped silicon wafers. In addition, it was proven that bulk Cu contamination was easily introduced in the heavily boron-doped silicon wafer by polishing the wafer with a slurry containing Cu in the presence of amine additives.

Soil Contamination Analysis and its Treatment for Landfilled Area (폐기물 매립지반 오염도 분석 및 처리방안에 대한 연구)

  • Shin, Eun-Chul;Kang, Jeong-Ku;Jang, Woo-Lam
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • When some structures are constructed over the sanitary landfill, the waste should be treated by means of replacement and other ways. Otherwise, various problems like a ground contamination, settlement, reduction of bearing capacity and others may be generated. To find out the optimal method of treatment, the properties of the ground have to be inspected. In this study, the preliminary investigation was conducted to find out the characteristic of this site which is considered as insanitary waste landfill. Furthermore, the shape and the amount of the waste was investigated by subsurface investigation like a boring and sampling methods. In addition, the degree of ground contamination and disposal method of refuse was examined.

  • PDF

Evaluation of Microbiological Contamination of Water Purifiers at Two Universities in Chungcheong Region

  • Jin Young Yun
    • Biomedical Science Letters
    • /
    • v.29 no.4
    • /
    • pp.256-262
    • /
    • 2023
  • The purpose of this study is to investigate microbial contamination in water purifiers from two universities (A and B) in Chungcheong region and to evaluate about the harmfulness of the isolated bacteria to the human. The degree of microbiological contamination of six water purifiers at university A was investigated three times from July 2018 to September 2019, and nine water purifiers at university B were investigated in 2023. The isolated bacteria were biochemically identified using an API kit and Vitek-2 system, and then the bacteria were identified to the species level using MALDI-TOF MS. In addition, the possibility of human infection of the isolated bacteria was evaluated through a literature search. In July 2018 and September 2019, the number of bacteria isolated inside the faucet was below the acceptable standard for hot water, but exceed for cold water in all water purifiers. In January and September 2019, bacteria exceeding the acceptable standards were isolated nine times from the cold water of six water purifies (a total of 12 water purifiers). Bacteria identified by MALDI-TOF MS included anaerobic bacteria (Clostridium novyi, Clostridium themopalmarium etc.), Gram-positive bacilli (Microbacterium testaceum, Arthrobacter woluwensis etc.), and Gramnegative bacilli (Acinetobacter nosocomialis, Comamonas kerstersii etc.), which are difficult identify by biochemical methods. In conclusion, bacteria exceeding the acceptable standard were isolated from the cold water of most of the water purifiers. Most of the isolated bacteria were low-pathogenic bacteria from natural environment, but opportunistic bacteria that can cause infection in humans were also isolated from some water purifiers.

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination (지반 오염도 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가)

  • Oh, Myoung-Hak;Kim, Yong-Sung;Park, Jun-Boum
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.45-54
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.

Visualization and contamination analysis for groundwater quality of CDEWSF in Gwangju area using statistical method (통계적 기법을 이용한 광주지역 민방위비상급수용 지하수 수질 오염도 분석 및 시각화 연구)

  • Jang, Seoeun;Lee, Daehaeng;Kim, Jongmin;Kim, Haram;Jeong, Sukkyung;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.122-133
    • /
    • 2018
  • In this study, groundwater quality data measured for 11 years from 2006 to 2016 were analyzed statistically for 101 civil defense emergency water supply facilities (CDEWSF) in the Gwangju area. The contamination level was quantified into four grades by using excess drinking water quality standards, average concentration analysis, and tendency analysis results for each facility. On the basis of this approach, the groundwater contamination degree of each item was evaluated according to land use status, installation year, depth, and geological distribution. The contamination grade ratios, which were obtained by analyzing three contamination indicators (water quality exceeded frequency, average concentration analysis, and trend analysis) for 15 items on statistically significant of civil defense emergency water was relatively high, in the order of Turbidity (51.5 %) > Color (32.7 %) > Nitrate nitrogen (28.7 %) > Hardness (25.7 %). As a result of the contamination grade analysis, except for the items of Turbidity, Color, and Nitrate nitrogen, the contamination levels were distributed in various degrees from "clean (0)" to "seriously contaminated (3)." Regarding the contamination grade of 12 items, 25 % of the total were classified as "possibly contaminated (1)," and 75 % were rated "clean (0)." The four items (Turbidity, Color, Nitrate nitrogen, and Hardness) for which contamination indication rate were evaluated as "high" by the were visualized on a contamination map.

A Study on the Improvement of Temporary Ventilation of long tunnel Using the Field Measurement data (현장 실측을 통한 장대터널 공사중 환기 문제점 연구)

  • Hong, Chang-Soo;Hwang, Dae-Jin;Kang, Hyun-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1350-1357
    • /
    • 2010
  • In tunnelling, temporary ventilation is very important factor in the safety of worker and the work efficiency which is affected by visibility. There are a lot of problems in the recent tunnel construction, because the longer the tunnel, the more the present design doesn't satisfy the allowable standard about dust and air pollution. Especially, In case the length of tunnel is more than 1,000m, the ventilation efficiency tends to decrease. In this study, the field measurement of the degree of contamination was performed near the face of tunnel. Based on the results obtained, the main factors of problem in temporary ventilation are the difference of temperature between outside and inside, the rate of leakage of ventilation duct and the dust and so on. It maybe helpful to the solution of problems, and also the accurate ventilation estimate.

  • PDF