DOI QR코드

DOI QR Code

Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination

지반 오염도 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가

  • Oh, Myoung-Hak (Coastal Engrg. Research Dept., Korea Ocean Research & Development Institute) ;
  • Kim, Yong-Sung (Dept. of Civil, Urban & Geosystem Engrg., Seoul National Univ.) ;
  • Park, Jun-Boum (Dept. of Civil, Urban & Geosystem Engrg., Seoul National Univ.)
  • 오명학 (한국해양연구원 연안개발연구본부) ;
  • 김용성 (서울대학교 지구환경시스템공학부) ;
  • 박준범 (서울대학교 지구환경시스템공학부)
  • Published : 2006.07.30

Abstract

Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.

전기비저항콘은 현장에서 지반의 오염대를 조사하는데 상대적으로 경제적인 비용으로 적용될 수 있다. 그러나, 전기비저항 결과만에 의한 해석은 정량적 데이터베이스의 부족과 함수비 등의 다른 지반공학적 영향인자들에 의해 모호한 결과를 나타낼 수 있다. 본 연구에서는 지반오염조사에서의 전기비저항 측정기법을 보완하기 위하여 정전용량 측정기법을 도입하여 중금속과 유류로 오염된 지반에서의 적용성을 평가하고자 하였다. 함수비와 오염물질의 종류에 따른 전기비저항과 정전용량의 변화를 평가하기 위하여 실내모형시험을 수행하였으며, 그 결과 전기비저항과 유전상수를 통시에 측정하여 분석함으로써 오염대의 감지에 신뢰도를 높일 수 있는 것으로 나타났다. 전기비저항과 정전용량 측정기법은 중금속으로 오염된 포화지반과 지하수대 상부에 존재하는 디젤유 오염층을 감지하는 데 적용성이 높은 것으로 나타났다.

Keywords

References

  1. 오명학 (2005), 흙의 전기적 특성 평가를 통한 지반오염 감지시스템 개발, 서울대학교 박사학위논문
  2. 오명학, 김용성, 유동주, 박준범 (2005), '함수비와 중금속 오염도에 따른 유전상수의 변화', 한국지반공학회논문집, 제21권 5호, pp.231-241
  3. 오명학, 이기호, 박준범 (2004), '함수비와 간극수 오염이 불포화사질토의 전기비저항에 미치는 영향', 대한토목학회 논문집, 제24권 1C호, pp.27 -34
  4. 윤길림, 유찬, 이영남, 윤춘경, 이용길 (1998), '오염지반의 전기비저항치와 토성과의 상관성 연구', 한국지반공학회논문집, 제14권 2호, pp.79-92
  5. 이주형, 오명학, 박준범, 김형석(2002), '수분함량과 측정주파수에 따른 사질토 지반의 유전상수 변화', 한국지반공학회논문집, 제18권 6호 pp.l29-139
  6. Brandl, H. and Robertson, P. K. (1996), 'Geoenvironmenta1 site investigation and characterization', 2nd International Congress on Environmental Geotechnics, pp.l17-140
  7. Campanella, R. G. and Davies, M. P. (1997), 'In-situ testing for geo-environmental site characterization: A mine tailings example', 14th ICSMFE, pp.43-46
  8. Campanella, R. G. and Weemees, I. (1990), 'Development and use of an electrical resistivity cone for groundwater contamination studies', Canadian Geotechnical Journal, 27, pp.557-567 https://doi.org/10.1139/t90-071
  9. Campbell, J. E. (1990), 'Dielectric properties and influence of conductivity in soils at one to fifty megahertz', Soil Science Society of American Journal, 54, pp.332-341 https://doi.org/10.2136/sssaj1990.03615995005400020006x
  10. Kaya, A. and Fang, H. Y. (1997), 'Identification of contaminated soils by dielectric constant and electrical conductivity', Journal of Environmental Engineering, Vol.123, No.2, pp.169-177 https://doi.org/10.1061/(ASCE)0733-9372(1997)123:2(169)
  11. Fukue, M., Minato, T., Matsumoto, M., Horibe, H. and Taya, N. (2001), 'Use of a resistivity cone for detecting contaminated soil layers', Engineering Geology, 60, pp.361-369 https://doi.org/10.1016/S0013-7952(00)00116-2
  12. Lee, J. H., Oh, M. H., Park, J., Lee, S. H. and Ahn, K. H. (2003) 'Dielectric dispersion characteristics of sand contaminated by heavy metal, landfill leachate and BTEX', Journal of Hazardous Materials, 105, pp.83-102 https://doi.org/10.1016/j.jhazmat.2003.07.004
  13. Morabito, P., Lanciani, I. and Benoit, J. (1998), Electrical resistivity cone penetration (ERCPTU) testing at the Treasure island national geotechnical experimentation site in San Franscisco, California, NSF Report
  14. Oh, M. H., Kim, Y. S., Park, J. and Yoon, H. S. (2005), 'Complex permittivity of sand at low frequency', Journal of the Korean Geotechnical Society, Vol.21, No.2, pp.93-103
  15. Okoye, C. N., Cotton, T. R. and O'Meara, D. (1995), 'Application of resistivity cone penetration testing for qualitative delineation of creosote contamination in saturated soils', Geoenvironment 2000, ASCE, pp.93-104
  16. Piccoli, S. and Benoit, J. (1995), 'Geo-environmental testing using the envirocone', Geoenvironment 2000, ASCE, pp.151-166
  17. Rowe, R. K., Shang, J. Q. and Xie, Y. (2001), 'Complex pennittivity measurment system for detecting soil contamination', Canadian Geotechnical Journal, 39, pp.498-506
  18. Santamarina, J. C. and Fam, M. (1997), 'Dielectric permittivity of soils mixed with organic and inorganic fluids (0.2 GHz to 1.30 GHz)', Journal of Environmental and Engineering Geophysics, 2(1), pp.37-51 https://doi.org/10.4133/JEEG2.1.37
  19. Santamarina, J. C., Klein, K. A. and Fam, M. A. (2001), Soils and Waves, John Wiley & Sons
  20. van Nostrand R. G. and Cook K. L. (1966), Interpretation of Resistivity Data, U.S. Geological Survey, Professional Paper 499, USGS, Washington D.C