• Title/Summary/Keyword: contamination degree

Search Result 338, Processing Time 0.041 seconds

Studies on Sanitary Conditions in a Special Grade Chicken Processing Plant in Korea I. Storage Period of Packed Chicken Meat in relation to the Bacterial Contamination of Each Processing Part (특급도계장의 위생실태에 관한 연구 I. 작업부분별 세균오염도 측정)

  • 오경록
    • Korean Journal of Poultry Science
    • /
    • v.13 no.1
    • /
    • pp.41-48
    • /
    • 1986
  • In order to investigate the storage period of packed chicken meat in relation to the bacterial contamination of each processing part, a special grade poultry processing plant located at Dongdoochun-City, Gyeonggi-Do, was surveyed mainly in point of sanitary conditions. The results are summarized as follows. 1. processing room near reception and packing room next to shipping area showed the highest bacterial counts in air. 2. Equipments and instruments for slaughtering also showed a high degree of bacterial contamination even before the operation. This finding suggested that the possibility of the bacterial contamination of carcasses through equipments and instruments would be high, if the continuous sanitary control measures are not properly taken. 3. The bacterial count of scalding water was 3${\times}$10$\^$7/ for standard plate count and 4${\times}$10$\^$5/ for most probable number of coliform bacteria at 1 hour after the start of operation. These values were maintained until the completion of processing. 4. At the ending of chilling process, the bacterial counts of chilling water were 3.3 ${\times}$10$^4$ and 3.0${\times}$10$^3$for standard plate count, when the volume of water used per bird were 21 and 51, respectively. Bacterial contamination was further decreased about 10$\^$-3/-10$\^$-4/ times as the effective chlorine concentration in chilling water was maintained about 50 ppm. 5. An average standard plate count of the residual water In abdominal cavity of carcasses was 3.9${\times}$10$^4$immediate after chilling, however, it increased to 4.7${\times}$10$\^$7/ when the carcasses were packed and stored for 10 days at 4$^{\circ}C$. off-odour development was observed as the bacterial count was not less than 10$\^$6//$m\ell$ of the residual water of the packed carcasses. Data indicated that if the standard plate count of the residual water in abdominal cavity of carcasses was not less than l0$^4$immediate after chilling, the packed chicken meat would not be stored longer than 5 days at 4$^{\circ}C$.

  • PDF

Availability of Heavy Metals in Soils with Different Characteristics and Controversial Points for Analytical Methods of Soil Contamination in Korea (토양특성별 중금속 유효도와 토양오염 평가방법의 개선점)

  • Jung, Goo-Bok;Kim, Won-Il;Lee, Jong-Sik;Shin, Joung-Du;Kim, Jin-Ho;Yun, Sun-Gang
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.2
    • /
    • pp.106-116
    • /
    • 2005
  • This experiment was conducted to investigate available extraction capacity and potential mobility of heavy metal according to the distribution property and contamination level of heavy metals in soils and to suggest a reform measure of soil environment assessment methodology applied with soil quality and the official soil heavy metal test methods in domestic and foreign countries. The soils were collected from the natural forest paddy with long-term application of same type fertilizer, and paddies near metal mine and industrial complex. The post-treatment methods of soil were partial extraction, acid digestion and sequential extraction methods. For the heavy metal contents with different soil properties, it was shown that their natural forest and paddy soil were slightly low and similar to the general paddy soil, while their paddies near metal mine and industrial complex were higher than the standard level of Soil Environment Protection Act. Heavy metal concentrations in the soils with different soil properties had difference between $HNO_3\;and\;HNO_3+HCl$ extractant by US-EPA 3051a method. There were highly significant positive relationships in both two methods. It was appeared that the higher extractable concentration ratio with 0.1N-HCl to total heavy metal content with $HNO_3+HCl$ extractant the greater total heavy metal content. There were highly significant positive correlationship between total heavy metal content and extractable content with 0.1N-HCl. For extractable capacity of soil extractable solution compared to the total heavy metal content it was appeared that it extractable method with 0.1N-HCl was higher than those with EDTA and DTPA. In extractable ratio with 0.1N-HCl in the contaminated paddy soils near mine and industrial complex, it was shown that the lower soil pH, the higher total heavy metal content. The order of a potential mobility coefficient by distribution of heavy metal content with ie different typies in the soil was Cd>Ni>Zn>Cu>Pb. It could be known that contamination characteristics of heavy metals with different types of soils were affected by different heavy metal components, contamination degree and soil chemical properties, and heavy metal concentration with different extractable methods had great variations with adjacent environment. To be compared with assessment methodology of soil environment impact at domestic and foreign countries with our results, it might be considered that there was necessary to make a single analysis method based on total heavy metal content with environmental overloading concept because of various analysis methods for total heavy metal content and present analysis method with great variation according to soil environment. In spite of showing higher concentration of heavy metal with acidic digestion than the extractable method, it might be considered that there is need to be adjusted the national standard of soil heavy metal contamination.

Chemical Speciation of Arsenic in the Water System from Some Abandoned Au-Ag Mines in Korea (국내 폐금은광산 주변 수계내의 As의 화학적 특성)

  • 이지민;이진수;전효택
    • Economic and Environmental Geology
    • /
    • v.36 no.6
    • /
    • pp.481-490
    • /
    • 2003
  • The objectives of this study are (1) to determine the extent and degree of As contamination of the water and sediments influenced by mining activity of the abandoned Au-Ag mines, (2) to examine As speciation In contaminated water, (3) to monitor variation of As contamination in water system throughout the dry and wet seasons, and (4) to investigate the As chemical form in the sediments through the sequential extraction analyses. Natural water(mine water, surface water and groundwater) and sediments were collected in six abandoned Au-Ag mine(Au-bearing quartz veins) areas. The contamination level of As in mine water of the Dongil(524${\mu}m$/L) is more higher than the tolerance level(500 ${\mu}m$/L) for waste water of mine area in Korea. Elevated levels of As in stream water were also found in the Dongil(range of 63.7∼117.6 ${\mu}m$/L.) and Gubong(range of 56.1∼62.9 ${\mu}m$/L) mine areas. Arsenic contamination levels in groundwater used by drinking water were more significant in the Dongil(11.3∼63.5 ${\mu}m$/L), Okdong(0.2∼68.9 ${\mu}m$/L) and Gubong(2.0∼101.0${\mu}m$/L) mine areas. Arsenate[As(V), $H_2AsO_4^-$] is more dominant than arsenite[As(III), $H_3AsO_3$] in water system of the most mine areas. The concentration ratios of As(III) to As(total), however, extend to the 95% in stream water of the Okdong mine area and 70∼82% in groundwater of the Okdong and Dongjung mine areas. As a study of seasonal variation in the water system, relatively high levels of As from the dongil mine area were found in April rather than in September. Sequential extraction analysis showed that As was predominantly present as coprecipitated with Fe hydroxides from sediment samples of the Dongjung and Gubong mine(35.9∼40.5%), which indicates its possibility of re-extraction and inducing elevated contamination of As in the reductive condition. In sediments from the Dongil, Okdong and Hwachon mine area, high percentage(55.2∼83.4%) of As sulfide form was found.

Assesment of Indoor Air Quality within Public Transport Vehicles operating in specified locations throughout Seoul (서울 일부 지역 교통수단의 실내 공기질 평가)

  • Sohn Jong-Ryeul;Choi Dal-Woong;Choi Jung-Sook;Woo Wan-Gi
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.12-20
    • /
    • 2006
  • This paper was conducted concerning the degree of indoor air quality in public transport vehicles such as taxicabs, buses and subway trains, as sampled through the active participation of drivers and passengers in Seoul between 13th August 2005 and 2nd November 2005. The results were summarized as follows: 1. Among the measured substances especially respirable particulate matters ($PM_{10}$), total bacteria counts (TBC) and carbon dioxide ($CO_2$) exceeded the standard level of $150{\mu}g/m^3,\;800CFU/m^3$ and 1000ppm. 2. The concentration of carbon dioxide ($CO_2$) in taxi recorded 2491ppm, which is more than the standard amount of 1000ppm. This level was comparatively higher than all other public transportation methods. Total bacteria counts (TBC) in bus and subway recorded $1082CFU/m^3\;and\;1856CFU/m^3$, respectively. 3. The drivers who regularly work long hours showed the higher concern about contamination of the air inside the public transport vehicles and they considered it to be worse than the air outside. In contrast, the general public showed less concern about the air quality inside the public transport vehicles. However, they too acknowledged that the quality of the air inside the public transport vehicles was poor. In regards to the degree of indoor air quality in the public transport vehicles, a counterplan must be implemented urgently to effectively combat the excessive levels of $PM_{10}$, microorganism and $CO_2$. We need to gather more conclusive evidence pertaining to other possible contaminants and influencing factors.

Disorder of Endothelia Vessels' Functional State with Malignant Tumors in Patients Exposed Anthropogenic Radiation

  • Pak, Laura;Noso, Yoshihiro;Chaizhunusova, Nailya;Manambaeva, Zukhra;Adylkhanov, Tasbolat;Takeichi, Nobuo;Olzhaev, Sayakhat;Aldyngurov, Daniyar;Tuleutayeva, Raikhan;Argynbekova, Ainur;Tanysheva, Gulyash;Zhazykbayeva, Lashyn;Baissalbayeva, Ainur;Rakhypbekov, Tolebay
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.575-579
    • /
    • 2016
  • The aim of this research is to determine the characteristics of endothelial factors and the hemostatic system conditions with malignant neoplasms patients, which were exposed to ionizing radiation. Total number of examined people is 223, 153 of them are patients with gastrointestinal tract oncopathology. The article presents the results of the analysis of numerical indicators of endothelial condition and platelet hemostasis of patients, who had cancer. They lived in the regions of Kazakhstan, subjected to contamination of radionuclides as a result of nuclear weapons tests, which took place in this region from 1949 to 1989. These results then were compared to cancer patients and healthy individuals with no radiation risk. The study revealed the presence of higher levels of endothelial dysfunction and following trigger of the hemostatic system in patients with malignant tumors of the gastrointestinal tract. In particular, the defined high degree of endothelial dysfunction include endothelium-dependent vasodilation, content desquamated endothelial cells in peripheral blood and von Willebrand factor. These indicators have a clear correlation with the degree of disorder of studied parameters of the hemostasis, which can cause the development of thrombotic complications.

Detection of CGMMV from Commercial Cucumber Seed and Resistance Test of Cultivars (오이 종자로부터 CGMMV의 검출과 품종 저항성 검정)

  • Ko, Sug-Ju;Lee, Yong-Hwan;Cha, Kwang-Hong;Park, Jin-Woo;Choi, Hyeong-Gug
    • Research in Plant Disease
    • /
    • v.10 no.2
    • /
    • pp.154-158
    • /
    • 2004
  • To analyze the relationship between CGMMV occurrence and seed contamination by cucumber cultivars, cucumber cultivars of CGMMV infected field and diseased degree were investigated in cucumber main cultivation regions of Jeonnam province from 1999 to 2002. While the diseased degree was different by years and cultivars, CGMMV occurred for 4 years in 'Janghyeongnakhap', for 3 years in 'Jangjukcheongjang', and for 2 years in 'Gyeoulsali' and 'Gyeoulnagi'. CGMMV was detected in seeds of 'Janghyeongnakhap' and 'Jangjukcheongjang' by ELISA test, and seed of 'Jangjukcheongjang' showed positive reaction in bioassay. As a result of resistant test of 34 cultivars to CGMMV, all cultivars showed mosaic symptoms in pot test but only 'Hanboksamcheok' showed mild mosaic symptom in field test.

Determination by Neutron Analysis of Mercury Residues in Foodstuffs (방사화분석법에 의한 식품중의 잔류수은의 정량)

  • Chun, Sea-Yull
    • Korean Journal of Food Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.135-143
    • /
    • 1971
  • In order to find out the degree of mercury contamination of common foodstuffs a series of determination was carried out by a highly sensitive activation analysis and the following results were obtained. 1. Polished rice contained 0.050 ppm of mercury whereas rice bran had 0.095 ppm mercury which was found in other grain in lesser degree. 2. Vegetables and fruits also contained $0.035{\sim}0.190\;ppm$ of mercury with relatively small variations from sample except persimmon which had a considerably higher amount of mercury. 3. Soybean sprout contained an unexpectantly high amount of mercury. 4. Of the animal products chicken and egg contained more mercury than the meat.

  • PDF

Quality Properties of Semi-dried Persimmons with Various Drying Methods and Ripeness Degree (다양한 건조방법과 감의 성숙도에 따른 반건시 품질특성)

  • 정경미;송인규;조두현;추연대
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.189-194
    • /
    • 2004
  • This experiment was carried out to compare the quality of semi-dried persimmon according to various drying methods and ripeness degree of persimmons. Most of persimmons were dried naturally there were much opportunities of contamination by impurities, microorganism and discoloration. There were need for developing various drying methods and knowing proper mature degree of persimmons in order to enhance the quality of semi-dried persimmons. Drying time of semi-dried persimmons by hot-air, far infrared ray and dehumid drying could be shorten approximately 11∼12 days, comparing with natural drying. And the loss ratio of natural drying and artifical drying were 7.0% and 0.0%. The moisture content of natural drying and dehumid drying were simillar and the hardness were very low in comparing other drying methods. Average pannel scores in semi-dried persimmons after drying showed that dehumid drying and natural drying were excellent in total prefernce ; 3.9 and 3.4, respectively. Unriped persimmons showed lower moisture content, color values and higher hardness than riped and overriped persimmons. The total preference of riped and overriped fruit were superior than unriped fruit.

Development of a Garlic Peeling System Using High-Pressure Water Jets (III) - Introduction of a microbial control system - (습식 마늘박피 시스템 개발 (III) - 미생물 제어 시스템의 도입 -)

  • Kim J.;Bae Y. H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.17-24
    • /
    • 2005
  • An efficient microbial control system was introduced into a garlic peeling system using pressurized water in order to improve the quality and the shelf-life of peeled garlic. High microbial density of the spoiled peeled garlic and the water used for peeling and washing indicated that an efficient microbial control system is necessary far the peeling system. Though Pseudomonas spp. and Penicillium spp. were closely related to the spoilage of peeled garlic, the spoilage of peeled garlic was thought to be caused mainly by nonspecific increase in microbial density. The shelf-life of the garlic peeled by pressurized water was longer than that of the garlic peeled by pressurized air, and the degree of damage had great effect on the shelf-life of peeled garlic. Ozonated water was effective in decreasing the microbial contamination and in increasing the shelf-life of peeled garlic. Based on the findings of the study, following improvements were made to the garlic peeling system using pressurized water; 1) the water circulation system was modified in order to completely separate the water for washing from the water for garlic peeling, 2) filtration and cooling equipments were introduced into the circulation system of the water for peeling, and 3) an ozone generator which could continuously supply ozonated water (dissolved ozone concentration of 0.4 ppm) was attached to the circulation system of the water for washing.

A Study on the VOCs Contamination of Ambient Air int Kyonggi-do Area (III) (경기도 환경대기중 휘발성유기화합물의 오염실태 조사연구 (III))

  • 김종보;김종찬;최승석;임흥빈;최양희;이수문
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.63-70
    • /
    • 2002
  • We investigated the concentration degree of VOCs for ambient air in the air environment control area of Kyonggi-do in 2001. The VOCs showing higher concentration were in the ascending order of Toluene > n-Butane > 1-Butene > Benzene > n-Hexane. The concentration distribution ratio mentioned above showed almost same pattern in each city. The relative concentration ratio of Benzene, Toluene, Ethylbenzene, Xylenes which are aromatic VOCs were 1 : 6.3 : 0.6 : 1.6. It was similar to the pattern in 1999 but different from the pattern in 2000. In the aspect of seasons, the highest B.T.E.X concentration was indicated in fall and in the aspect of areas, the higher concentration showed in the ascending order of Buchon > Ansan > Kwangmyong > Shihung > Sungnam. The average concentration of target VOCs for ambient air in the air environment control area of Kyonggi-do showed lower concentration than the metropolis of Seoul but higher concentration than Kwang-ju city and Dae-gu city. The amount of total VOCs was increasing, comparing with it last year and the more increasing tendency is anticipated so that it will need to establish the proper regulative criteria.