• 제목/요약/키워드: contact failure

검색결과 536건 처리시간 0.028초

철도차량 차륜의 잔류응력 평가 (Evaluation of Residual Stress of railway wheel)

  • 서정원;구병춘;이동형;정흥채
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.208-213
    • /
    • 2002
  • Railway wheel and axle are the most critical components in railway system. A wheel and axle failure can cause a derailment with its attendant loss of life and property. The service conditions of railway vehicles have become severe in recent years due to a general increase in operating speeds. Therefore, more precise evaluation of wheelset strength and safety has been desired. Damages of railway wheel are a spatting by wheel/rail contact and thermal crack by braking heat etc. One of the main source of damage is a residual stress. therefore it is important to evaluate exactly. A Residual stress of wheel is formed at the process of heat treatment when manufacturing. it is changed by contact stress developed by wheel/rail contact and thermal stress from heat induced in braking. The objective of this paper is to estimate the variation and magnitude of the residual stress of railway wheel.

  • PDF

Electrical Impedance Change due to Contamination at the Contact Interface of Connectors for Automobile Crank Shaft Position Sensor

  • Kim, Young-Tae;Sung, In-Ha;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권2호
    • /
    • pp.46-52
    • /
    • 2004
  • Numerous connectors are used in automobiles for transmission of electrical signals across various electro-mechanical components. The connectors must operate with high reliability in order to minimize failures due to signal degradation. In this work, the effects of contamination at the contact interface of connectors used fur automobile crankshaft position sensor on the impedance change were investigated. An experimental set-up was built to simulate the electrical signal transmitted from the sensor to the engine control unit through a connector. Output from the connector was investigated using connectors contaminated with engine block residues and water droplets. It was found that slight contamination of the connectors could lead to significant signal degradation which can lead to engine failure. Also, the effect of water in the connector altered the signal severely. However, the signal gradually regained the original state as the water evaporated from the interface.

해수로 오염된 처점의 개간이-크의 발생과 소멸 (Arcing and Quenching of the Contacts Contaminated with Sea Water)

  • 조광현;박상길;박정후
    • 대한전기학회논문지
    • /
    • 제34권4호
    • /
    • pp.135-143
    • /
    • 1985
  • The failure and erosion of relay contacts mainly depend on the presence of particles deposited on the contact surface in various contaminated atmospheres. In this paper, the effects of sea water and circuit parameters on the arcing and quenching of magnet relay contacts are studied. The sea water pollutants of relay contact surface have led to increase the arcing numbers on making contact, and the mean arc durations on breaking contacts. Moreover, the maximum surge voltage and mean arc duration between relay contacts are also varied significantly by the circuit parameters. The effects of the spark quenching circuits using condenser of diode on the arcing of contacts are also discussed.

  • PDF

전력릴레이 고장사고 사례분석 및 고장예측 알고리즘 연구 (A Study on Fault Prediction Algorithm and Failure Instance Analysis of Electric Power Relay)

  • 김용규;곽동걸;이승철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.15-16
    • /
    • 2015
  • According to 2014 fire statistical yearbook in the National Fire Data System, a main cause of fire is electrical fire except carelessness fire. Joint/contact badness is the one of the main cause of electrical fire. Furthermore, power relays which are used in electric panel board, motor control center and automation controller, are main element of automation system in the industry field. Overload, voltage unbalance and open-phase due to joint/contact badness of terminal make electric accidents or electrical fires. In order to prevent joint/contact badness of terminal, this paper proposes a sensing circuit of chattering, tracking, arc current, voltage unbalance and open-phase etc. Some experimental tests of the proposed apparatus confirm practicality and validity of the theoretical results.

  • PDF

OLED Panel 검사 시에 Probe의 실시간 Contact 확인 가능한 시스템에 관한 연구 (A study of the system that enables real-time contact confirmation of probes in OLED panel inspection)

  • 황미섭;한봉석;한유진;최두선;김태민;박규백;이정우;김지훈
    • Design & Manufacturing
    • /
    • 제14권2호
    • /
    • pp.21-27
    • /
    • 2020
  • Recently, LCD (Liquid Crystal Display) has been replaced by OLDE (Organic Light Emitting Diode) in high resolution display industry. In the process of OLDE production, it inspects defective products by sending a signal using a probe during OLED panel inspection. At this time, the cause of the detection of failure is divided into two. One is the self-defect of the OLED panel and the other is the poor contact occurring in the process of contact between the two. The second case is unknown at the time of testing, which increases the time for retesting. To this end, we made a system that can identify in real time whether the probe is in contact during the inspection. A contact probe unit was designed for the system, and a stage system was implemented. An inspection system was constructed through S / W and circuit configuration for actual inspection. Finally, a system that can check contact and non-contact in real time was constructed.

A modified RBSM for simulating the failure process of RC structures

  • Zhao, Chao;Zhong, Xingu;Liu, Bo;Shu, Xiaojuan;Shen, Mingyan
    • Computers and Concrete
    • /
    • 제21권2호
    • /
    • pp.219-229
    • /
    • 2018
  • In this paper, a modified rigid body spring model (RBSM) is proposed and used to analyze the damage and failure process of reinforced concrete (RC) structures. In the proposed model, the concrete is represented by an assembly of rigid blocks connected with a uniform distribution of normal and tangential springs to simulate the macroscopic mechanical behavior of concrete. Steel bars are evenly dispersed into rigid blocks as a kind of homogeneous axial material, and an additional uniform distribution of axial and dowel springs is defined to consider the axial stiffness and dowel action of steel bars. Perfect bond between the concrete and steel bars is assumed, and tension stiffening effect of steel bars is modeled by adjusting the constitutive relationship for the tensile reinforcement. Adjacent blocks are allowed to separate at the contact interface, which makes it convenient and easy to simulate the cracking process of concrete. The failure of the springs is determined by the Mohr-Coulomb type criterion with the tension and compression caps. The effectiveness of the proposed method is confirmed by elastic analyses of a cantilever beam under different loading conditions and failure analyses of a RC beam under two-point loading.

전단하중을 받는 알루미늄 하니콤 샌드위치의 체결방식이 체결부의 파손에 미치는 영향 연구 (Effect of joining methods on the failure of aluminum honeycomb sandwich joints under shear loading)

  • 박용빈;권진회;최진호;조현일
    • 한국항공우주학회지
    • /
    • 제39권7호
    • /
    • pp.643-651
    • /
    • 2011
  • 본 논문에서는 전단하중을 받는 다양한 알루미늄 샌드위치 체결부의 파손 특성에 대한 시험 연구를 수행하였다. 3종류의 인서트 형식 체결부와 2종류의 포팅 형식 체결부에 대해 총 60개의 시편을 제작하여 시험을 수행하였다. 시험 결과, 인서트 형식 체결부의 경우 쓰루 클리어런스(through-clearance) 인서트를 사용한 경우의 파손하중이 가장 높게 나타났으며 포팅 형식 체결부의 경우 딤플 와셔(dimple washer)가 있을 때 전단하중이 약10% 향상되는 것을 확인할 수 있었다. 예상대로 면재의 두께가 증가할수록 전단파손하중도 증가하고, 특히 하중치구와 접촉하고 있는 상부 면재의 효과가 지배적인 것을 확인하였다.

만성 심부전 환자의 자가간호 이행 관련요인 (Factors Influencing Adherence to Self Care in Patients with Chronic Heart Failure)

  • 손연정;김선희;김기연
    • 성인간호학회지
    • /
    • 제23권3호
    • /
    • pp.244-254
    • /
    • 2011
  • Purpose: The objective of this study was to evaluate adherence to self-care and identify associated factors in outpatients with Heart Failure (HF). Methods: Using a cross-sectional design, a convenience sample of 249 outpatient clinic patients were recruited at S university hospital. Between October 2009 and December 2009, data were collected through questionnaires and medical record review. Results: The total mean score of adherence to self-care was $18.07{\pm}3.56$ out of a possible 45 points. Among self-care dimensions, adherence to medication and low salt diet was high, while lower adherence was reported in contact with health professionals if symptoms such as weight gain, edema and fatigue were presented. Multivariate analysis adjusted for other socio-demographic and clinical factors showed that disease knowledge related to heart failure (p<.001) and left ventricular ejection fraction (p=.027) were independent predictors of adherence to self-care. These factors explained 23% of total variance in the adherence to self-care. Conclusion: Heart failure patients with higher disease knowledge and those who have good systolic function may be more likely to engage in adherence to self-care than those with lack of disease knowledge and low contractility. Further research is needed to confirm these results and identify other predictors of adherence to self-care.

다중균열 구조물의 소성붕괴거동 평가 (Evaluation of Plastic Collapse Behavior for Multiple Cracked Structures)

  • 문성인;장윤석;김영진;이진호;송명호;최영환;황성식
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1813-1821
    • /
    • 2004
  • Until now, the 40% of wall thickness criterion, which is generally used for the plugging of steam generator tubes, has been applied only to a single cracked geometry. In the previous study by the authors, a total number of 9 local failure prediction models were introduced to estimate the coalescence load of two collinear through-wall cracks and, then, the reaction force model and plastic zone contact model were selected as the optimum ones. The objective of this study is to estimate the coalescence load of two collinear through-wall cracks in steam generator tube by using the optimum local failure prediction models. In order to investigate the applicability of the optimum local failure prediction models, a series of plastic collapse tests and corresponding finite element analyses for two collinear through-wall cracks in steam generator tube were carried out. Thereby, the applicability of the optimum local failure prediction models was verified and, finally, a coalescence evaluation diagram which can be used to determine whether the adjacent cracks detected by NDE coalesce or not has been developed.

The role of mass transfer layer on the tribological characteristics of silver-coated surfaces

  • Yang, Seung-Ho;Kong, Ho-Sung;Yoon, Eui-Sung;Kim, Dae-Eun
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.153-154
    • /
    • 2002
  • Wear map of silver coatings on AISI 52100 has been constructed to delineate the wear transition behavior with the change in operating conditions in various environments. Three main regimes were clearly identified: (i) elastic/plastic deformation of silver coating without failure. (ii) mild wear regime after initial failure of silver coating and (iii) severe wear regime. In the mild wear regime, the contact surfaces were covered with transfer layers of agglomerated wear particles. The transfer layer acted as a protective layer and resulted in low friction even after the initial failure of the coated films, whose characteristics were strongly dependent on both the operating and environmental conditions. Also, the existence of the critical sliding speed, above which no transfer layer was able to form, was discussed in the work.

  • PDF