• Title/Summary/Keyword: contact effect

Search Result 3,294, Processing Time 0.032 seconds

A Finite Element Analysis of Non-Isothermal Sheet Metal Forming Process (비등온 박판 성형공정의 유한요소해석)

  • ;Wagoner, R. H.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1119-1128
    • /
    • 1990
  • A numerical method for analyzing non-isothermal, rigid-viscoplastic deformation problems has been presented. As an application, a stretch forming of sheet metals, including temperature effect, has been analyzed by a three-dimensional finite element method. Bishop`s step-wise decoupled method is adopted to solve thermomechanical coupling between deformation and heat transfer. Using the method, the effect of temperature on strain distribution during stretch forming is investigated. By comparison of the non-isothermal results with isothermal analysis, the importance of including temperature effects in the analysis of metal forming problems is emphasized. The predicted results were in good agreement with the existing experimental measurements at the different punch temperatures and dome heights investigated. It is also found that any increase of the punch temperature appeared to postpone the strain localization process by lowering the peak strain in the critical punch-sheet contact region and by normalizing strain distribution within the specimen.

Effect of White Water Quality on the Adsorption of Cationic PAM on Fibers (백수의 수질이 양이온성 PAM의 흡착에 미치는 영향)

  • Lee, Ji-Young;Lee, Hak-Lae;Youn, Hye-Jung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.1 s.109
    • /
    • pp.1-9
    • /
    • 2005
  • Many factors which affect the adsorption of cationic polymers on fibers and fines have been investigated by many researchers that include contact time, pH, collision frequency, properties of cationic polymers and adsorbent, etc. But the effect of white water quality on the adsorption of cationic polymer have not been examined throughly. In this study, the adsorption of cationic PAM was analyzed as a function of white water quality. The adsorption of the cationic PAM was analyzed by two analysis methods, Kjeldahl nitrogen content measurement and electrokinetic measurements. When the distilled water was used, adsorbed amount of C-PAM and zeta-potential of fibers increased as a function of the addition of C-PAM. When closure level increased, nitrogen content of fibers increased indicating that the cationic PAM was adsorbed. Zeta-potential of fibers, however, showed no significant change with the increased addition of C-PAM. This showed that adsorption of C-PAM was not reflected by zeta-potential of fibers due to the deteriorated efficiency of C-PAM by the anionic contaminants in white water.

Fabrication and Characterization of FET Device Using ZnO Nanowires (ZnO 나노와이어를 이용한 FET 소자 제작 및 특성 평가)

  • Kim, K.W.;Oh, W.S.;Jang, G.E.;Park, D.W.;Lee, J.O.;Kim, B.S.
    • Journal of Surface Science and Engineering
    • /
    • v.41 no.1
    • /
    • pp.12-15
    • /
    • 2008
  • The zinc oxide(ZnO) nanowires were deposited on Si(001) substrates by thermal chemical vapour deposition without any catalysts. SEM data suggested that the grown nanostructures were the well-aligned ZnO single crystals with preferential orientation. Back-gate ZnO nanowire field effect transistors(FET) were successfully fabricated using a photolithography process. The fabricated nanowire FET exhibits good contact between the ZnO nonowire and Au metal electrodes. Based on I-V characteristics it was found out that the ZnO nanowire revealed a characteristic of n-type field effect transistor. The drain current increases with increasing drain voltage, and the slopes of the $I_{ds}-V_{ds}$ curves are dependent on the gate voltage.

Comparative Study on Collision Strength of LNG Carriers

  • Choe, Ick-Hung;Kim, Jae-Hyun;Ahn, Ho-Jong;Kim, Oi-Hyun
    • Journal of Ship and Ocean Technology
    • /
    • v.5 no.3
    • /
    • pp.36-44
    • /
    • 2001
  • The collision energy absorbing characteristics of side structure of the LNG carriers which have the cargo containment systems of the spherical and the membrane types are compared. A failure mechanism of the double hull side structures of 130, 000 $m^3$ class LNG carriers under sideways collision event has been simulated by using the detailed finite element calculations. In ship collision analysis, the finite element method based on explicit time integration has been use[1 with much success. Finite element modeling techniques for detail description of structural members antral ship motion regarding the dynamic behavior allowed to investigate the effect of bow shape and the initial contact position on side shell of collided ship. In the numerical simulations of the ship-to-ship sideways collision, the effect of the colliding bow shapes and the change of the colliding ship draft are investigated. The critical collision energy which is absorbed by a side structure of a collided ship until the fore-end of colliding ship arrives at the boundary of the cargo tank is calculated. The critical speed of specified colliding ships which can not penetrate the boundary of the LNG cargo tank of the collided ship under collision accident if evaluated.

  • PDF

Numerical Study About Compression Effect of Porous Electrodes on the Performance of Redox Flow Batteries (다공성 전극의 압축률이 레독스흐름전지의 성능에 미치는 영향에 대한 수치해석적 연구)

  • Jeong, Daein;Jung, Seunghun
    • Journal of ILASS-Korea
    • /
    • v.22 no.2
    • /
    • pp.69-79
    • /
    • 2017
  • When designing a redox flow battery system, compression of battery stack is required to prevent leakage of electrolyte and to reduce contact resistance between cell components. In addition, stack compression leads to deformation of the porous carbon electrode, which results in lower porosity and smaller cross-sectional area for electrolyte flow. In this paper, we investigate the effects of electrode compression on the cell performance by applying multi-dimensional, transient model of all-vanadium redox flow battery (VRFB). Simulation result reveals that large compression leads to greater pressure drop throughout the electrodes, which requires large pumping power to circulate electrolyte while lowered ohmic resistance results in better power capability of the battery. Also, cell compression results in imbalance between anolyte and catholyte and convective crossover of vanadium ions through the separator due to large pressure difference between negative and positive electrodes. Although it is predicted that the battery power is quickly improved due to the reduced ohmic resistance, the capacity decay of the battery is accelerated in the long term operation when the battery cell is compressed. Therefore, it is important to optimize the battery performance by taking trade-off between power and capacity when designing VRFB system.

An experimental study of Antiallergic activity of Medicinal Acupunture Solution of Acanthopanax senticosus(Rupr. et Maxim.) (자오가피(刺五加皮) 약침액(藥針液)의 항(抗)알러지 효과(效果)에 대한 실험적(實驗的) 연구(硏究))

  • Yoon, Jong-Tae;Seol, In-Chan;Kim, Dong-Hee;Kim, Sung-Hoon;Kim, Han-Sung
    • Journal of Acupuncture Research
    • /
    • v.18 no.2
    • /
    • pp.136-149
    • /
    • 2001
  • Objetives : This study was done to evaluate the antiallegic effect of medicinal acupuncture solution of Acanthopanax senticosus(Rupr. et Maxim;abbreviated as ASMA), studies were done experimentally. Methods : For this aim MTT assay, anaphylaxis reaction, DTH, histamine release, IgE production and vascular permability was evaluated. Results : ASMA didn't show an effective cytotoxicity on the mouse lung fibroblast. It insignifcantly suppressed histamine release from mast cells induced by compound 48/80, while it significantly reduced IgE production and SRBC-challenged DTH(Delayed type hypersensitivity). ASMA effectively suppressed anaphylactic reaction induced by compound 48/80. However, it didn't inhibit vascular permeability and contact dermatitis significantly. Conclusion:Medicinal acupucture solution had antialletgic effects. Acanthopanax senticosus medical acupuncture depress the allergy reaction. Especially in anaphylactic type, the effect was good.

  • PDF

A Study on the Coating Fracture in Silicon Nitride Bilayer : II. Effect of Coating Thickness (질화규소 이층 층상재료에서 코팅층의 파괴에 관한 연구 : II Coating Thickness의 영향)

  • 이기성;이승건;김도경
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.1
    • /
    • pp.48-54
    • /
    • 1998
  • The effect of coating thickness on the contact fracture was studied, in Si3N4 coated Si3N4-BN system When the elastic/plastic mismatch is relatively large betwen two layers in bilayer certain critical coating thickness was required to prevent cone crack initiation and this critical thickness was decreased by de-creasing the elastic/plastic mismatch,. In addition the required critical thickness should be increased when higher loads apply. In conclusion an appropriate coating thickness should be designed by elastic/plastic mismatch between two layers and environment (applied load) to prevent the coating fracture

  • PDF

Thermoelectric Seebeck and Peltier effects of single walled carbon nanotube quantum dot nanodevice

  • El-Demsisy, H.A.;Asham, M.D.;Louis, D.S.;Phillips, A.H.
    • Carbon letters
    • /
    • v.21
    • /
    • pp.8-15
    • /
    • 2017
  • The thermoelectric Seebeck and Peltier effects of a single walled carbon nanotube (SWCNT) quantum dot nanodevice are investigated, taking into consideration a certain value of applied tensile strain and induced ac-field with frequency in the terahertz (THz) range. This device is modeled as a SWCNT quantum dot connected to metallic leads. These two metallic leads operate as a source and a drain. In this three-terminal device, the conducting substance is the gate electrode. Another metallic gate is used to govern the electrostatics and the switching of the carbon nanotube channel. The substances at the carbon nanotube quantum dot/metal contact are controlled by the back gate. Results show that both the Seebeck and Peltier coefficients have random oscillation as a function of gate voltage in the Coulomb blockade regime for all types of SWCNT quantum dots. Also, the values of both the Seebeck and Peltier coefficients are enhanced, mainly due to the induced tensile strain. Results show that the three types of SWCNT quantum dot are good thermoelectric nanodevices for energy harvesting (Seebeck effect) and good coolers for nanoelectronic devices (Peltier effect).

Discharge Properties of Torch-Type Atmospheric Pressure Plasma and Its Local Disinfection of Microorganism (토치형 상압 플라즈마의 방전특성과 미생물의 국부 살균효과)

  • Son, Hyang-Ho;Lee, Won-Gyu
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.835-839
    • /
    • 2011
  • The characteristics of torch-type atmospheric pressure plasma and its sterilization effects have been analyzed. The length of plasma flame was varied with the level of applied voltage and the mixture gases composed of argon and oxygen. The effect of plasma flame on the temperature increase of surface treated was limited to $43^{\circ}C$ as a maximum temperature under exposing time of 10 min. The sterilization for E. coli was strongly affected by the applied voltage, the oxygen ratio in the mixture gas and the treatment time. At a high concentration of ozone, the increase of treatment time under the direct contact with plasma flame yields to maximize the effect of the sterilization on E. coli.

The Effect of a Wedged Rocker Sole on Ankle Joints during Gait (보행에서 외측 경사진 굽은 밑창이 발목 운동에 미치는 영향 분석)

  • Kwon, Sung-Hyuk;Kim, Choong-Sik;Kim, Hee-Jin;Ryu, Tae-Beum;Chung, Min-Geun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.93-101
    • /
    • 2008
  • Wedged soles and rocker soles are widespread shoe designs used to prevent the disorders and reduce the pain of the lower extremity caused by arthritis or diabetic feet. In this study, the effect of a shoe with a laterally wedged sole and a rocker sole simultaneously was analyzed on the kinematics and kinetics of the ankle joint during normal walking. Eight male participants without a history of lower extremity disorders were recruited. Each participant performed twenty walking cycles for each of three walking conditions: bare foot, wearing normal shoes and wearing shoes with laterally wedged rocker soles. The differences between the three walking conditions were statistically investigated including spatio-temporal variables, angular displacements, joint moments and ground reaction forces. The results showed that the laterally wedged rocker sole decreased the sagittal variation of angular displacements as well as the frontal/sagittal average moment on the ankle joints compared to the flat sole. In addition, the rate of angular displacements and loading decreased during the heel contact phase.