• 제목/요약/키워드: construction site control system

검색결과 209건 처리시간 0.028초

RFID를 활용한 적산온도방식의 콘크리트 강도 추정 시스템 기초 연구 (Concrete Strength Prediction System by Maturity Method using RFID)

  • 박소현;오용석;송정화;오건수
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.399-404
    • /
    • 2008
  • The objective of this study is to develop the predicting method of concrete strength when remove concrete form-work without making cement test piece at construction site. For this purpose, this study catches the Maturity Method by using RFID, the usability of which is now being emphasized at site, accumulates and record the strength data, which can be gained with the results of existing Maturity Method method that is accompanied with strength estimation study, in database, and finally proposes the system structure which can check the estimated strength by Maturity Method. The merits of this method by using of Maturity Method are as follows; More objective, precise, and rapid decision can be made to the concrete strength and about the maintaining period of concrete form and form support. More efficient control of integrated material management system can be possible. Architectural field example using RFID can be suggested more concretely. RFID applicability can be extended by using DB of material integration management system.

  • PDF

지하수댐 물막이벽 시공법과 해안지역 염수침입 방지기술 개선 방안 (The Study on Constructing Underground Wall to Prevent Seawater Intrusion on Coastal Areas)

  • 부성안;이기철;김진성;정교철;고양수
    • 지질공학
    • /
    • 제12권2호
    • /
    • pp.215-234
    • /
    • 2002
  • 지하수댐은 대용량의 지하수를 효과적으로 확보할 수 있는 시설로서 저류수는 유역조건과 대수층조건, 상류부 오염원 분포와 수질에 따라 상수도용, 중수도용, 농업용 또는 공업용 등으로 다양하게 이용할 수 있으므로 적절한 지하수범 설치 방법은 용수부족을 해결할 수 있는 주요 기술의 하나이다. 지하수법을 활성화시키기 위해서는 대수층 위치 및 지층에 맞는 적절한 차수공법의 선택과 정밀한 물막이벽 시공, 대수층 구조·수문·물수지 등의 정확한 분석, 장기적인 지하수 이용계획과 저류역내 수질보전대책 수립, 수위·수질에 대한 장기 모니터링 실시로 지속적인 유지관리, 지속가능한 대용량 취수기술에 대한 조속한 연구, 지하수댐 개발로 인한 주변환경에 미치는 영향에 대한 철저한 분석 및 대책 수립 등이 필요하다. 그리고 해안지역 지하수법에서 발생하는 염수침입 현상을 방지하는 방안으로 물막이벽을 이중으로 설치하는 방법이 있다.

웹기반 화상 감시 시스템의 구현 (An Implementation of Image Security System Based on Web)

  • 박영석;조평기
    • 융합신호처리학회논문지
    • /
    • 제1권1호
    • /
    • pp.74-81
    • /
    • 2000
  • 기존의 전용선을 사용하는 화상 감시 시스템의 문제점을 해결하기 위해 인터넷을 이용한 3계층 웹기반 화상 감시 모델을 제안하고 시스템으로 구현하였다. 개발된 시스템은 3계층 웹기반 분산제어 모델을 채택함으로써 기존의 중앙 집중제어 방식의 시스템 안정성 문제를 해결하였고, 원격 웹브라우저에서 그룹으로 등록된 복수의 화상 감시 싸이트(Site)를 인터넷을 통해 원격제어 및 자동감시가 가능하다. 또한 자바 가상 기계(Java Virtual Machine) 코드와 가상 인스트루먼트(Virtual Instrument) 개념에 의한 운용 소프트웨어 설계로 다양한 종류의 컴퓨터와 OS에서도 운용이 가능하다. 또한 인터넷을 통한 네트워크 구성이므로 별도의 네트워크 구축비용이 들지 않으며, 웹서버를 사용한 운용 소프트웨어의 배포 및 보수 유지가 이루어지므로 소프트웨어 갱신 등에 따른 관리의 효율성을 크게 개선 할 수 있다.

  • PDF

중견건설업체의 다중현장관리를 위한 자재소요계획모델 (Material Planning Model for Multi-Project Management in Medium-sized Construction Companies)

  • 정성림;한주연;김경래;신동우
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.598-601
    • /
    • 2003
  • 건축공사의 규모가 대형화, 복잡화, 다양화 되면서 여러 현장에서 공사수행에 따른 많은 정보가 발생하여 본사로 보고 되고 있다. 이러한 정보들 중에서 매개 현장 및 다중 현장을 동시에 관리하기 위해서는 필요정보만을 추출하여 경영진이 의사결정을 할 수 있는 지원체계의 필요성이 증가하고 있다. 하지만 중견건설업체의 경우 대기업과 비교할 때 본사 조직의 미비 및 관리업무 시스템이 취약하여 다중현장 관리가 어려운 실정이다. 특히 이러한 현장관리에 있어서 자원관리는 프로젝트 관리자의 중요한 관리대상이다. 그러나 자원계획을 일정정보와의 연계가 없이 주로 담당자의 경험과 판단에 근거하여 수립하기 때문에 일정이 변경될 때마다 계획을 수작업으로 수정해야하는 실정이며, 이로 인한 불필요한 공기지연이나 재고비용이 발생하고 있다. 본 연구에서는 중견건설업체가 다수 현장을 동시에 관리할 수 있도록 현장의 작업일보와 공정관리 소프트웨어의 연계를 통한 자재소요계획모델을 제시한다.

  • PDF

중견건설업체의 다중현장관리를 위한 자재조달계획 지원 모델 (Material Planning Model for Multi-Project Management in Medium-sized Construction Companies)

  • 정성림;한주연;김경래;신동우
    • 한국건설관리학회논문집
    • /
    • 제5권2호
    • /
    • pp.106-114
    • /
    • 2004
  • 건축공사의 규모가 대형화, 복잡화, 다양화 되면서 개별 현장에서 공사수행에 따른 많은 정보가 발생하여 본사로 보고 되고있다. 이러한 정보들 중에서 개별 현장 및 다중 현장을 동시에 관리하기 위해서는 필요정보만을 추출하여 경영진이 의사결정을 할 수 있는 지원체계의 필요성이 증가하고 있다. 하지만 중견건설업체의 경우 대형건설업체와 비교할 때 본사 조직의 미비 및 관리업무 시스템이 취약하여 다중현장관리가 어려운 실정이다. 특히 이러한 현장관리에 있어서 자원관리의 대부분을 차지하는 자재관리는 프로젝트 관리자의 중요한 관리대상이다. 그러나 자재조달계획을 일정정보와의 연계가 없이 주로 담당자의 경험과 판단에 근거하여 수립하기 때문에 일정이 변경될 때마다 계획을 수작업으로 수정해야하는 실정이며, 이로 인한 불필요한 공기지연이나 재고비용이 발생하고 있다. 본 연구에서는 중견건설업체가 다수 현장을 동시에 관리할 수 있도록 현장의 작업 일보와 공정관리 소프트웨어의 연계를 가정한 자재조달계획 지원모델을 제시한다.

Preliminary numerical analysis of controllable prestressed wale system for deep excavation

  • Lee, Chang Il;Kim, Eun Kyum;Park, Jong Sik;Lee, Yong-Joo
    • Geomechanics and Engineering
    • /
    • 제15권5호
    • /
    • pp.1061-1070
    • /
    • 2018
  • The main purpose of retaining wall methods for deep excavation is to keep the construction site safe from the earth pressure acting on the backfill during the construction period. Currently used retaining wall methods include the common strut method, anchor method, slurry wall method, and raker method. However, these methods have drawbacks such as reduced workspace and intrusion into private property, and thus, efforts are being made to improve them. The most advanced retaining wall method is the prestressed wale system, so far, in which a load corresponding to the earth pressure is applied to the wale by using the tension of a prestressed (PS) strand wire. This system affords advantages such as providing sufficient workspace by lengthening the strut interval and minimizing intrusion into private properties adjacent to the site. However, this system cannot control the tension of the PS strand wire, and thus, it cannot actively cope with changes in the earth pressure due to excavation. This study conducts a preliminary numerical analysis of the field applicability of the controllable prestressed wale system (CPWS) which can adjust the tension of the PS strand wire. For the analysis, back analysis was conducted through two-dimensional (2D) and three-dimensional (3D) numerical analyses based on the field measurement data of the typical strut method, and then, the field applicability of CPWS was examined by comparing the lateral deflection of the wall and adjacent ground surface settlements under the same conditions. In addition, the displacement and settlement of the wall were predicted through numerical analysis while the prestress force of CPWS was varied, and the structural stability was analysed through load tests on model specimens.

건설자재 통합정보 관리를 위한 시스템 모델 구현 (Development of System Model for Integrated Information Management of Construction Material)

  • 한충한;주기범
    • 정보처리학회논문지D
    • /
    • 제16D권3호
    • /
    • pp.433-440
    • /
    • 2009
  • 최근 건설 분야의 정보화 기술이 발달함에 따라 건설업무의 생산성 향상과 비용 절감을 위한 다양한 건설자재 정보 서비스 차원의 web 기반 온라인 시스템이 급증하는 추세이다. 그러나 이러한 시스템들이 제공 중인 품질 및 규격등 건설자재정보가 표준화되지 못하여 특정자재의 정보획득시 여러 정보시스템을 이용하거나 유사한 작업을 반복하는등 건설현장 실무자들의 자재정보 활용에 있어 많은 어려움을 겪고 있다. 이에 본 연구에서는 국제 데이터 상품 속성 시스템(GDAS, Global Data Alignment System)을 기준으로 건설자재 정보항목을 정형화하고 건설자재 통합정보 관리를 위한 시스템 모델을 설계하였다. 본 시스템은 건설공정별 국제 표준분류체계(OmniClass Part-22)와 유엔 표준 제품 및 서비스 분류체계(UNSPSC, United Nations Standard Products and Services Classification)를 적용한 건설 자재의 자동 분류, 자재정보의 조건별 복합검색, 전자카탈로그의 실시간 자동구현, RFID 검색 및 관리 기능을 지원함으로써 자재정보의 효율적인 관리 및 활용이 가능하다.

발파진동 제어에 의한 특수구간 터널굴착에 관한 연구 (A Study on Tunnel Excavation by Controlled Blast Vibration at Particular Environment Conditions)

  • 최형빈;임한욱
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.257-267
    • /
    • 2000
  • It was difficult to apply conventional excavation methods in some sections from Seoul to Pusan high speed rail road construction of 1 lot 2, due to highway concrete road, gas pipe, water pipe and nearby factories with automatic control system machine. To excavate safely and efficiently in these sections new blast patterns were employed within allowable blast vibration level, by test blast and controlled vibration by sequential blast. Behaviors of the rock mass including convergence and displacement around tunnel were measured with construction works and the crack width in concrete wall was also monitored for controlling allowable limits. The results can be summarized as follow : 1. The allowable blast vibration level in structure site is less 1.0cm/sec for highway concrete, 0.5 cm/sec for gas pipe, water pipe and building housing and 0.3 cm/sec for automatic control system machine. 2. The convergence displacement, single rod extensometer and multi rod extensometer around tunnel and cracks in concrete wall were measured, it was confirmed that the measured values were converged within allowable level. 3. The empirical formular of ground vibrations with 90% confidence lines for PD-3 was given as follow. $$V_{90%}=45.549({\frac{D}{\sqrt{W}}})^{-1.353}$$

  • PDF

비례제어밸브용 디지털 앰프.컨트롤러에 대한 연구 (A Study on a Digital Amplifier.Controller for Proportional Control Valve)

  • 이재천;고재욱;권태황;신행봉
    • 유공압시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.19-25
    • /
    • 2011
  • This study presents the design of digital amplifier.controller for a proportional control valve and the development of PID discrete control scheme by using RCP(Rapid Controller Prototyping) system. RCP system is the device to embed the control code developed in PC into the microcontroller on-site. Ramp input test using the digital amplifier.controller developed in this study was carried out for the proportional control valve of domestic production and Bosch Rexroth respectively. The instability problem occurred around maximum displacement of localized valve spool at ramp input test was solved by supplementing offset current to the duty ratio of PWM(Pulse Width Modulation) driving signal to the solenoid. The comparison of test results between localized proportional control valve and Bosch Rexroth's product shows that the characteristics obtained by ramp input test and static flow gains are alike each other. Two valves are about the same in dead bands and hysteresis characteristics.

한국형 대형관입시험 장비의 개발 및 현장 적용성 평가 (Performance of KICT-type Large Penetration Test (LPT))

  • 김영석;김영진;홍성완;강재모;지완구
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2007년 가을학술발표회
    • /
    • pp.603-610
    • /
    • 2007
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760 mm and 150 kg, respectively. Semi-auto hammer drop system identical with KS F2307 and JI A1259S was adopted. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. The hammer energy level was measured during the performance of the KICT-type LPT using SPI system (quality control system from driven piles).

  • PDF