• 제목/요약/키워드: construction Joints

검색결과 604건 처리시간 0.026초

Serviceability design of a cold-formed steel portal frame having semi-rigid joints

  • Lim, J.B.P.;Nethercot, D.A.
    • Steel and Composite Structures
    • /
    • 제3권6호
    • /
    • pp.451-474
    • /
    • 2003
  • Details are given of a cold-formed steel portal framing system that uses simple bolted moment-connections for both the eaves and apex joints. However, such joints function as semi-rigid and, as a result, the design of the proposed system will be dominated by serviceability requirements. While serviceability is a mandatory design requirement, actual deflection limits for portal frames are not prescribed in many of the national standards. In this paper, a review of the design constraints that have an effect on deflection limits is discussed, and rational values appropriate for use with cold-formed steel portal frames are recommended. Adopting these deflection limits, it is shown through a design example how a cold-formed steel portal frame having semi-rigid eaves and apex joints can be a feasible alternative to rigid-jointed frames in appropriate circumstances.

프리캐스트 콘크리트 전단키의 역학적 거동에 관한 실험연구 (An Experimental Study on the Behavior of Precast Concrete Shear Keys)

  • 오병환;이준서;이형준;임동환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 봄 학술발표회 논문집
    • /
    • pp.86-89
    • /
    • 1992
  • In the precast segmental method of construction, segments of a structure are precast, assembled, and tied together by post-tensioning to form the structure. Shear strength and behavior of points in precast concrete structures are important problems in the design of these structures. An experimental program was set up study the shear behavior of precast concrete shear keys. experimental models of keyed joints include a single key, representing one of a series include the shear key shape, d/h ratio(1/4, 1/5, 1/7), and inclined angle (45。 60。 75。). Two different types of joints, i.e., epoxied joint and dry joints were studied. From the present tests, it is found that epoxied joints have higher shear strength than those of dry joints, and that high d/h ratio keys have higher shear strength than those of low d/h ratio keys. The keys with 60。-inclined angle shows the highest shear strength among various angles.

  • PDF

내부 환보강 T형 관이음부의 정적강도 (Static Strength of Internally Ring-Stiffened Tubular T-Joints)

  • 조현만;류연선
    • 한국해양공학회지
    • /
    • 제18권6호
    • /
    • pp.70-78
    • /
    • 2004
  • In order to increase the load carrying capacity of tubular structures, the joints of tubular members are usually reinforced with various reinforcement system. A stiffening method with internal ring stiffeners is effectively used for the steel tubular joint with a large diameter. In this study, the behavior of internally ring-stiffened tubular T-joints subjected to axial loading is assessed. For the parametric study, nonlinear finite element analyses are used to compute the static strength on non-stiffened and ring-stiffened T-joints. Based on the numerical results, an internal ring stiffener is found to be efficient in improving the static strength. The influence of geometric parameters has been determined, and the reinforcement effect are evaluated. Based on the FE results, regression analises are performed considering the practical size of ring stiffener. Finally strength estimation formulas for ring-stiffened tubular T-joints are proposed.

초지연제 혼입률에 따른 저발열 콘크리트의 양생온도별 기초물성평가 (Fundamental Properties of Low-Heat Concrete According to the Mixing Rate of Super Retarding Agent)

  • 박병주;최윤호;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.90-91
    • /
    • 2020
  • As the construction site has become narrower recently, the importance of mass concrete is naturally being highlighted as skyscrapers become popular. However, it is not possible to install the entire volume per day if the mass concrete is installed due to the Remicon 8⦁5 system and the 52-hour workweek system. When the mass concrete base is divided into several days, cold joints occur because the consolidation of joints is not integrated due to different degree of hardening in the case of the previous layer and the next day. As a result, existing research has shown that if super retarding agent are mixed into Ready Mixed Concrete (hereinafter referred to as Remicon) using sugar as a raw material to delay the curing time of concrete, cold joints are inhibited and cracks are inhibited by reducing the initial hydration heat.

  • PDF

Characteristics of CFRP strengthened tubular joints subjected to different monotonic loadings

  • Prashob, P.S.;Shashikala, A.P.;Somasundaran, T.P.
    • Steel and Composite Structures
    • /
    • 제32권3호
    • /
    • pp.361-372
    • /
    • 2019
  • Tubular joints are used in the construction of offshore structures and other land-based structures because of its ease of fabrication. These joints are subjected to different environmental loadings in their lifetime. At the time of fabrication or modification of an existing offshore platform, tubular joints are usually strengthened to withstand the environmental loads. Currently, various strengthening techniques such as ring stiffeners, gusset plates are employed to strengthen new and existing tubular joints. Due to some limitations with the present practices, some new techniques need to be addressed. Many researchers used Fibre Reinforced Polymer (FRP) to strengthen tubular joints. Some of the studies were focused on axial compression of Glass Fibre Reinforced Polymer (GFRP) strengthened tubular joints and found that it was an efficient technique. Earlier, the authors had performed studies on Carbon Fibre Reinforced Polymer (CFRP) strengthened tubular joint subjected to axial compression. The study steered to the conclusion that FRP composites is an alternative strengthening technique for tubular joints. In this work, the study was focused on axial compression of Y-joint and in plane and out of plane bending of T-joints. Experimental investigations were performed on these joints, fabricated from ASTM A106 Gr. B steel. Two sets of joints were fabricated for testing, one is a reference joint and the other is a joint strengthened with CFRP. After performing the set of experiments, test results were then compared with the numerical solution in ANSYS Parametric Design Language (APDL). It was observed that the joints strengthened with CFRP were having improved strength, lesser surface displacement and ovalization when compared to the reference joint.

경골목구조에서 구조재와 오에스비로 구성된 못 접합부의 인발 및 전단성능 (Withdrawal and Lateral Resistance of Nail Joints Composed of Dimension Lumber and OSB in Light-Frame Wood Construction)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권3호
    • /
    • pp.211-220
    • /
    • 2013
  • 경골목조건축에서 못 접합부는 수평하중을 지지하고 전달하도록 설계되지만, 바람으로 인한 상향력처럼 인발하중에 직면하기도 한다. 본 연구에서는 경골목조건축에서 일반적으로 사용되는 구조재와 덮개로 구성된 못 접합부에 대하여 인발성능과 2면 전단시험을 통해 인발 및 측방하중에 대한 내력성능을 시험하고 설계기준에 부합되는 가를 평가하였다. 인발하중에 대한 내력성능은 부재의 비중에 의해 크게 좌우되었으며 I형장선의 경우 낮은 밀도에도 불구하고 높은 인발성능을 나타내었다. 최대 인발하중은 기준허용 최대 인발하중보다 매우 높게 나타났다. 전단성능도 비중이 큰 낙엽송과 오에스비로 구성된 접합부가 비중이 작은 SPF와 오에스비로 구성된 접합부보다 높은 성능을 나타내었으며 모두 기준설계치보다 높은 성능을 나타내었다. 접합부의 변형은 주로 못의 휨 변형에 의한 것으로 나타났으며 SPF와 오에스비로 구성된 접합부에서의 못의 휨 변형이 현저하게 나타났다.

일체식교대 강교량의 거더-교대 연결부 상세의 거동평가를 위한 실험적 연구 (Experimental Study for Performance Evaluation of Structural Details of Girder-Abutment Joint in Integral Abutment Steel Bridge)

  • 김상효;윤지현;최우진;김준환;안진희
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.61-72
    • /
    • 2011
  • 본 연구에서는 일체식교대 강교량 거더-교대 연결부의 강체거동 및 균열저항성능의 향상을 위한 구조상세를 제시하고 그에 따른 연결부의 거동을 실험적으로 평가하였다. 거더-교대 연결부의 강체거동 및 균열저항성능을 향상시키기 위하여 전단연결재 및 tie bar를 적용한 연결부를 제시하였으며, 제시된 연결부 실험체와 기존 시공경험에 의해 설계된 연결부 실험체의 하중재하실험을 통하여 연결부의 성능 및 거동 특성을 검토하였다. 하중재하실험 결과, 모든 강 거더-교대 연결부 실험체들은 목표 설계하중 및 항복하중 이하에서 충분한 강성 및 균열저항 성능을 보여 강 거더-교대 연결부로 적용 가능하다. 하지만 실험체의 초기 강성, 균열의 진전형상 측면, 하중-변형률 측면에서 전단연결재와 tie bar가 적용된 강 거더-교대 연결부가 기존에 적용되어 왔던 강 거더-교대 연결부에 비하여 구조적으로 우수한 것으로 판단된다.

Analysis on mechanical behavior of dovetail mortise-tenon joints with looseness in traditional timber buildings

  • Li, Yizhu;Cao, Shuangyin;Xue, Jianyang
    • Structural Engineering and Mechanics
    • /
    • 제60권5호
    • /
    • pp.903-921
    • /
    • 2016
  • To study the effect of looseness on mechanical behavior of dovetail mortise-tenon joints, five dovetail mortise-tenon joints, including one intact joint and four loose joints, were fabricated and tested under cycle lateral loadings, and non-linear finite element models using the software ABAQUS were also developed. The effects of looseness on stress distribution, rotational stiffness and bearing capacity of joints were studied based on the analysis of test and simulation results. The results indicate that the hysteretic loops are anti-Z-shaped and present typical characteristics of pinching and slippage, the envelop curves of joints are classified as following two stages: elastic and strengthening stage. The peak stress, rotational stiffness and bearing capacity of joints were reduced due to looseness. The moment-rotation theoretical model of intact joint was simplified in terms of the relation of construction dimensions for buildings, and the moment-rotation theoretical model considering the effect of looseness was proposed and validated.

The influence of vertical ground motion on the seismic behavior of RC frame with construction joints

  • Yu, Jing;Liu, Xiaojun
    • Earthquakes and Structures
    • /
    • 제11권3호
    • /
    • pp.407-420
    • /
    • 2016
  • The aim of this study is to investigate the effect of vertical ground motion (VGM) on seismic behavior of reinforced concrete (RC) regular frame with construction joints, and determine more proper modeling method for cast-in-situ RC frame. The four-story RC frames in the regions of 7, 8 and 9 earthquake intensity were analyzed with nonlinear dynamic time-history method. Two different methods of ground motion input, horizontal ground motion (HGM) input only, VGM and HGM input simultaneously were performed. Seismic responses in terms of the maximum vertex displacement, the maximum inter-story drift distribution and the plastic hinge distribution were analyzed. The results show that VGM might increase or decrease the horizontal maximum vertex displacement depending on the value of axial load ratio of column. And it will increase the maximum inter-story drift and change its distribution. Finally, proper modeling method is proposed according to the distribution of plastic hinges, which is in well agreement with the actual earthquake damage.