• 제목/요약/키워드: constant output

검색결과 1,064건 처리시간 0.032초

극저온 환경에서의 정 출력 제어를 적용한 마이크로터빈의 새로운 시동 로직 개발 (New Start-Up Logic for Microturbine by Constant Power Control under an Extremely Low Temperature)

  • 노민식
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1249-1255
    • /
    • 2006
  • This paper presents a constant power control logic for perfect starting a microtubine in vehicle. Under extremely low temperature, performance of the start-up system is severely dropped than that of room temperature because of increasing of load of mechanical parts including engine core and drop of the lead-acid battery capacity. Unfortunately, performance drop of lead-acid battery makes severe problems that cause a malfunction of fuel and lubrication system and power fail of digital devices. So we propose the new start-up logic by constant output power control of lead-acid battery using PWM inverter controller for preventing above problems and keeping good performance of start-up system for microturbine. Also, we prove usefulness of new start-up logic through experimental results under $-32^{\circ}C$ ambient temperature.

정 전류원 이용한 치수(齒髓) 검사기 (An electric pulp tester using a constant current source)

  • 김재성;남기창;김수찬;이승종;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.720-723
    • /
    • 2003
  • Electric stimulation of teeth is used for assessing pulp vitality. Because of very high and wide range of impedance of the enamel, electric pulp testers use high voltage, high output impedance and alternative current source. Most pulp testers use voltage stimulation method and their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation in enamel thickness. In this study, we constructed a constant current source type of pulp tester with the maximum current of 150 uA.

  • PDF

Analysis and Design of Sliding Mode Control for a Single-Phase AC-DC Converter

  • Sawaengsinkasikit, Winyu;Tipsuwanporn, Vittaya;Tarasantisuk, Chanlit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2291-2294
    • /
    • 2003
  • In this paper, analysis and control design of ac-dc converter, normally nonlinear time-varying system, using sliding mode controller to achieve fast output voltage response, disturbance rejection and robust system in the presence of load variation are demonstrated. The objective of this method is to develop methodology for output voltage to be constant and input current sinusoidal that results in nearly unity power factor, respectively. In addition the converter can be also bidirectional power flow. Simulation results using Matlab/Simulink show the effectiveness of sliding mode control system compared with linear feedback controller to guarantee enhanced PF>0.98, THD<5%, and ripple output voltage is less than 1% at the maximum output power.

  • PDF

정 전압 출력을 갖는 벅-부스트 컨버터의 제어기 설계 (Controller Design of Buck-Boost Converter with Constant Voltage Output)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.42-50
    • /
    • 2015
  • The Buck-Boost converter consisted of two switches is more expensive than the conventional Buck converter, because of the increase of the components. However, it can control the DC voltage depending on the requested load voltage without additional circuits, because it can control the voltage under the relatively wide range of the load. Additionally, it can control the output voltage constantly under the variation of the input voltage. In the paper two control loops consisted of current and voltage control are designed. When two controllers are operated at the same time the problem of the output voltage is occurred. Therefore, the solution of the output voltage problem is proposed. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype system rated at 1kVA.

Suppression of Output Distortion in a Gyroscope using Fiber Amplifier/Source by Tracking of Optimum Modulation Amplitude

  • Park, Hee-Gap
    • Journal of the Optical Society of Korea
    • /
    • 제3권2호
    • /
    • pp.80-85
    • /
    • 1999
  • We propose and demonstrate a new scheme for suppression of output distortion in an open-loop gyroscope employing an erbium-doped fiber amplifier/source (FAS). In addition to the main modulation for the rotation rate measurement, a small auxiliary modulation at a different frequency is used to extract an error signal, which is necessary for keeping the quasi-dc component of the feedback signal power at a constant level for varying rotation rate. By active tracking of the optimum modulation condition using this two-frequency modulation scheme, we obtain stable gyro output with suppressed distortion as well as stable FAS characteristics. We also calculate the distortion in the gyro response due to the feedback effect, from which we estimate the FAS gyro output distortion due to the residual ac feedback effect when the dc feedback effect is removed by the proposed scheme. The measured residual deviation agrees reasonably with the estimation.

행렬 부등식 접근법을 이용한 센서 노이즈 비선형 시스템의 출력궤환 제어 (Output Feedback Control of a Class of Nonlinear Systems with Sensor Noise Via Matrix Inequality Approach)

  • 구민성;최호림
    • 제어로봇시스템학회논문지
    • /
    • 제21권8호
    • /
    • pp.748-752
    • /
    • 2015
  • We present an output feedback controller for a class of nonlinear systems with uncertain nonlinearity and sensor noise. The sensor noise has both a finite constant component and a time-varying component such that its integral function is finite. The new design and analysis method is based on the matrix inequality approach. With our proposed controller, the states and output can be ultimately bounded even though the structure of nonlinearity is more general than that in the existing results.

A SiGe HBT Variable Gain Driver Amplifier for 5-GHz Applications

  • 채규성;김창우
    • 한국통신학회논문지
    • /
    • 제31권3A호
    • /
    • pp.356-359
    • /
    • 2006
  • A monolithic SiGe HBT variable gain driver amplifier(VGDA) with high dB-linear gain control and high linearity has been developed as a driver amplifier with ground-shielded microstrip lines for 5-GHz transmitters. The VGDA consists of three blocks such as the cascode gain-control stage, fixed-gain output stage, and voltage control block. The circuit elements were optimized by using the Agilent Technologies' ADSs. The VGDA was implemented in STMicroelectronics' 0.35${\mu}m$ Si-BiCMOS process. The VGDA exhibits a dynamic gain control range of 34 dB with the control voltage range from 0 to 2.3 V in 5.15-5.35 GHz band. At 5.15 GHz, maximum gain and attenuation are 10.5 dB and -23.6 dB, respectively. The amplifier also produces a 1-dB gain-compression output power of -3 dBm and output third-order intercept point of 7.5 dBm. Input/output voltage standing wave ratios of the VGDA keep low and constant despite change in the gain-control voltage.

새로운 SEPIC-Flyback 컨버터의 동작특성 (The operating characteristics of novel SEPIC-Flyback converter)

  • 문승필;김수석;이태원;원충연;김영렬
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.526-529
    • /
    • 2004
  • A new SEPIC-Flyback convater is proposed. The proposed converter is the superposition of SEPIC and Flyback converter. Not only SEPIC output but also Flyback output could be fully regulated by constant frequency PWM control. Merged SEPIC and Flyback topology could share the transformer and power MOSFET. When the switch turns of one topology operates via capacitive energy transfer. Another topology acts as powering mode while the switch is off. So, it could increase power falsify per one cycle. The operating principle of the proposed converter is described below. Prototype featuring 24V input 48V output, 100kHz switching frequency, and 100W output is simulated under the proposed topology.

  • PDF

2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상 (Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters)

  • 김영신;이동춘;석줄기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

1차 측 제어 플라이벅 컨버터의 정전류 및 정전압 제어 (A Constant-Current and Constant-Voltage Control Method for Primary-Side Regulated Fly-Buck Converter)

  • 조영훈;장바울
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.30-38
    • /
    • 2023
  • In this paper, a constant current(CC) and constant voltage(CV) control method using a primary-side regulated(PSR) fly-buck converter is proposed. Because the primary-side structure of the fly-buck converter is the same as that of the synchronous buck converter, it always operates in continuous conduction mode(CCM). Therefore, in the proposed method, the load information on the secondary side can always be easily estimated by measuring the primary inductor current at the midpoint of the switch-on period. An accurate CC/CV control can be achieved through simple calculations based on this estimated information. Consequently, the proposed method is advantageous for optimizing the control performance of the PSR converter. The validity of the proposed control was verified using a 5 W prototype of a PSR fly-buck converter. The experimental results confirmed that the current reference of 500 mA was followed within the error range of 1.2%, and that the voltage reference of 12 V was followed within the error range of 1.8% despite the indirect control of the load current and output voltage from the primary side.