• Title/Summary/Keyword: consistency limit

Search Result 76, Processing Time 0.026 seconds

Reliability of structures with tuned mass dampers under wind-induced motion: a serviceability consideration

  • Pozos-Estrada, A.;Hong, H.P.;Galsworthy, J.K.
    • Wind and Structures
    • /
    • v.14 no.2
    • /
    • pp.113-131
    • /
    • 2011
  • Excessive wind-induced motion in tall buildings can cause discomfort, affect health, and disrupt the daily activities of the occupants of a building. Dynamic vibration absorbers such as the tuned mass dampers (TMDs) can be used to reduce the wind-induced motion below a specified tolerable serviceability limit state (SLS) criterion. This study investigates whether the same probability of not exceeding specified wind-induced motion levels can be achieved by torsionally sensitive structures without/with linear/nonlinear TMDs subjected to partially correlated wind forces, if they are designed to just meet the same SLS criterion. For the analyses, different structures and the uncertainty in the response, wind load and perception of motion is considered. Numerical results indicate that for structures that are designed or retrofitted without or with optimum linear TMDs and satisfying the same SLS criterion, their probability of exceeding the considered criterion is very consistent, if the inherent correlation between the wind forces is considered in design. However, this consistency deteriorates if nonlinear TMDs are employed. Furthermore, if the correlation is ignored in the design, in many cases a slightly unconservative design, as compared to the designed by considering correlation, is achieved.

Reliability Based Load Combination Criteria for Design of Reinforced Concrete Cylindric-ShellContainment Structures (신뢰성(信賴性) 이론(理論)에 기초(基礎)한 철근(鐵筋)콘크리트 원통-쉘 차폐(遮蔽) 구조물(構造物)의 설계하중(設計荷重) 조합(組合) 규준(規準))

  • Han, Bong Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.21-29
    • /
    • 1993
  • In this paper, a probability-based reliability analysis was proposed based on a finite element method-based random vibration analysis and serviceability limit state of structures. The limit state model defined for the study is a serviceability limit state in terms of the more realistic crack failure that might cause the emission of radioactive materials. The SAP V-2 is used for a three-dimensional finite element analysis of concrete containment structure, and the reliability analysis is carried out by modifying HRAS reliability analysis program for this study. In this study, the load factors for the design of reinforced concrete cointainment structures in Korea are proposed by considering appropriate load combination criteria for design, and the results are compared with the present ASME code. The proposed load factors were proved to be in accordance with a set of code performance objective and showed consistency in the limit state probability.

  • PDF

A Study on the Strength Characteristics of Lime-Soil Mixtures. (석회혼합토의 강도특성에 관한 연구)

  • 조성정
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.3
    • /
    • pp.46-59
    • /
    • 1980
  • This study was conducted to obtain the most effective distribution of grain size and the optimum lime content for lime-soil stabilization. To achieve the aim, the change of consistency, the characteristics of compaction and unconfined compressive strength were tested by adding of 0, 4, 6, 8, 10 and 12 percent lime by weight for all soils adjusted by given ratios of sand to clay. The results obtained were as follows; 1. There was a tendency that the plasticity index of lime-soil mixture was decreased by increasing the amount of lime, whereas the liquid limit was varied irregularly and the plastic limit was increased. 2. With the addition of more lime, the optimum moisture content of lime-soil mixture was increased, and the maximum dry density was decreased. 3. The optimum lime content of lime-soil mixture was varied from soil to soil, and the less amount of small grain size, the less value of optimum lime content. 4. The optimum distribution of grain size for lime-soil mixture was in the soil, having the ratio of about 60 percent of cohesive clay and about 40 percent of sand by weight. 5. In the soil having fine grain size, the effect of curing appeared for long periods of time, whereas the increasing rate of unconfined compressive strength was great on the soil of coarse grain size in the earlier stage of curing period.

  • PDF

Mode analysis and low-order dynamic modelling of the three-dimensional turbulent flow filed around a building

  • Lei Zhou;Bingchao Zhang;K.T. Tseb
    • Wind and Structures
    • /
    • v.38 no.5
    • /
    • pp.381-398
    • /
    • 2024
  • This study presents a mode analysis of 3D turbulent velocity data around a square-section building model to identify the dynamic system for Kármán-type vortex shedding. Proper orthogonal decomposition (POD) was first performed to extract the significant 3D modes. Magnitude-squared coherence was then applied to detect the phase consistency between the modes, which were roughly divided into three groups. Group 1 (modes 1-4) depicted the main vortex shedding on the wake of the building, with mode 2 being controlled by the inflow fluctuation. Group 2 exhibited complex wake vortexes and single-sided vortex phenomena, while Group 3 exhibited more complicated phenomena, including flow separation. Subsequently, a third-order polynomial regression model was used to fit the dynamics system of modes 1, 3, and 4, which revealed average trend of the state trajectory. The two limit cycles of the regression model depicted the two rotation directions of Kármán-type vortex. Furthermore, two characteristic periods were identified from the trajectory generated by the regression model, which indicates fast and slow motions of the wake vortex. This study provides valuable insights into 3D mode morphology and dynamics of Kármán-type vortex shedding that helps to improve design and efficiency of structures in turbulent flow.

The proposal on the new method for accurate to measure the plastic limits (정확한 소성한계 측정을 위한 새로운 실험법 제안)

  • Ko, Jae-Min;Lee, Byung-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.68-79
    • /
    • 2018
  • An examination of the characteristics of the ground material in is very important in a ground investigation. Casagrande classified soil using the material properties of soils. The liquid-plastic limit test is useful for obtaining basic information of soil, and is an effective method for classifying silt and clay, as well as the material properties, such as shear strength, shrinkage, and expansion. Unlike the liquid limit test, the plasticity limit test is due to the ambiguity of the test procedure. Many geotechnical engineers and scholars have questioned the test results. In this study, a new plasticity limit method was used to compare with the thread rolling method with kaolinite, ilite and bentonite at a certain ratio, and samples were collected from the west coast of Korea. As a result of the comparison, the test value of the new test method showed high reproducibility because the error range of the test value of the conventional thread rolling test was only 10% but the error range of the new test values decreased to 2%. The difference in the slope of the existing plasticity test values was 0.1519 ~ 0.1925, and the results of the test were similar or coincided with each other. Aone - point method was proposed to make it easier to apply the new test method.

Flame Diagnosis using Image Processing Technique

  • Kim, Song-Hwan;Lee, Tae-Young;Kim, Myun-Hee;Bae, Joon-Young;Lee, Sang-Ryong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.2
    • /
    • pp.45-51
    • /
    • 2002
  • Recently the interest for the environment is increasing. So the criterion for the evaluation of the burner has changed. For efficient driving problem, if the thermal efficiency is higher and the oxygen in exhaust gas is lower, then burner is evaluated better. For environmental problem. burner must satisfy NOx limit, soot limit and CO limit. Generally the experienced operator judge of the combustion status of the burner by the color of flame. we don't still have any satisfactory solution against it. the relation of the combustion status and the color of the flame hasn't still been established. This paper is the study about the relation of the combustion status and the color of the flame. This paper describes development of real time flame diagnosis technique that evaluate and diagnose combustion state such as consistency of components in exhaust gas, stability of flame in quantitative sense. In this paper, it was proposed on the flame diagnosis technique of burner using image processing algorithm, the parameter extracted from the image of the flame was used as the input variables of the flame diagnostic system. at first, linear regression algorithm and multiple regression algorithm was used to obtain linear multi-nominal expression. Using the constructed inference algorithm, the amount of NOx and CO of the combustion gas was successfully inferred. the combustion control system will be realized sooner or later.

Studies on the Engineering Characteristics of Alluvial Clayey Deposits in the Bay Area of Asan (II) (아산만지역 충적점토의 토질특성에 관한 연구(II))

  • 유능환;유연택
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.2
    • /
    • pp.55-66
    • /
    • 1988
  • This study was conducted to investigate the various engineering properties and correlationshops among the soil constants of alluvial clayey deposits distributed in the bay of Asan and their results are summarized as follows : 1. Grain size distribution of soil was consisted of 12 % of clay, 46-73 % of silt, 2-23 % of sand, and as for the consistency characteristics, 26-36 % of liquid limit, 18-21 % of plastic limit and 6-16 % of plastic index, and so the soil belonging to as a lower plastic nonorganic clay, it's specific gravity was 2,66-2.70, and the location on the plastic chart was approximately above the A-line. Z The natural moisture content and unit weight were 30-43 % and 1.76-1.87 g I cm$_3$, respectively, and according to increment of natural moisture content, the unit weight was decreased, and the initial void ratio and degree of saturation were shown of 0,87-1119 and 92- 100 %, most of saturated. 3. Cone resistance value which was shown 2.4 - 6.5 kg / $cm^2$ was a little lower and it was increased with the depth of layer and shown the formular $q_c=0.7_z+1.32$. 4. Unconfined compression strength was about 0.18-0.43kg /$cm^2$, cu, 0.1-0.22kg / $\psi$, $2-6^{\circ}$ under uu-test condition of triaxial, and CCU, 0.08-0.3 kg/cm , $\psi$, $12-18^{\circ}$ under the condition of cu-test. 5. Pre-consolidation load of characteristics of consolidation was 0.4-0.8 kg / $cm^2$, compression index, about 0.17-0.33. 6. Liquid limit and plastic index were incresased with the increment of clay content but most of alluvial clay was appeared as a normal through non-activity clay soil shown more natural moisture content than liquid limit, and their relationship as follows : LL=0.38( cy+54.8), PI=0.836(LL -17.8), PI =0.468(LL -0.48) 7. The initial void ratio presented correlationship of positive among clay content, natural moisture content and liquid limit, and that of reverse with unit weight, and their results as follws : $e_o=0.024(w_n+0.2)$, $e_o=e_o=0.0003c_y+0.0005 LL+0.0151 W_n+\frac{3.58}{r-t}-1.52$ 8. It was shown that the compression index has correlationship of postive among the clay content, liquid limit, plastic index, natural moisture content and initial void ratio, and their relationships as follows ; $c_c=0.44(e_o-0.47)$, $c_c=0.001$

  • PDF

Biological Distribution by Water Temperature and Refocus on the Theory of Critical Environmental Variation Quantum (수온환경변화에 따른 생물분포와 어업피해결정을 위한 임계환경변화량이론의 재조명)

  • Kang, Young-Joo;Kim, Ki-Soo
    • The Journal of Fisheries Business Administration
    • /
    • v.45 no.1
    • /
    • pp.1-16
    • /
    • 2014
  • The study attempts to show that the theory of critical environmental variation quantum(CEVQ) has a sound logical basis and empirical support. It is well known that the theory of critical environmental variation quantum is derived from the theory of biological probability distibution function and the central limit theorem(CLT) in statistics. The study uses the case study of fisheries damages compensation caused br the public marine construction undertaken in the area do Anjeong Bay in the city of Tongyeong for empirical test of theory of CEVQ. The results shows that the CEVQ theory perfoms a good job in measuring quantatively fjsheries damages caused by outflow of cold water due to the operation of LNG company since 2002. Therefore the study proves that the CEVQ theory is a good theory having internal consistency and empirical applicability.

UNIFORM ASYMPTOTICS IN THE EMPIRICAL MEAN RESIDUAL LIFE PROCESS

  • Bae, Jong-Sic;Kim, Sung-Yeun
    • Journal of the Korean Mathematical Society
    • /
    • v.43 no.2
    • /
    • pp.225-239
    • /
    • 2006
  • In [5], Csorgo and Zitikis exposed the strong $uniform-over-[0,\;{\infty}]$ consistency, and weak $uniform-over-[0,\;{\infty}]$ approximation of the empirical mean residual life process by employing weight functions. We carry on the uniform asymptotic behaviors of the empirical mean residual life process over the whole positive half line by representing the process as an integral form. We compare our results with those of Yang [15], Hall and Wellner [8], and Csorgo and Zitikis [5].

The Characteristics of Strength and Consolidation of Clayey Soil Dependent on pH of Soil Pore Water (간극수의 pH가 점성토의 강도와 압밀특성에 미치는 영향)

  • Lee, Ho-Jin;Kim, Byung-Il;Park, Sang-Kyu;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1047-1054
    • /
    • 2005
  • The purpose of this study is the understanding to changes in the characteristic of soil structure and classification, atterberg limits, undrained shear strength and consolidation of clayey soil dependent on pH of soil pore water. A series of tests including consistency tests, uniaxial compressive tests, vane tests and oedometer tests are performed on. The test results indicated that pH changes in the soil pH resulted in changes in the soil structure and classification, stress-strain behavior. Specially, when pH is conditioned to 7, liquid limit, undrained shear strength and preconsolidation pressure are the largest.

  • PDF