• Title/Summary/Keyword: connection type

Search Result 1,446, Processing Time 0.024 seconds

A Study on the Spatial Configuration of Type of Health Examination Center (건강검진센터의 공간유형과 구조체계에 관한 연구)

  • Song, Seung-Eon;Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.5
    • /
    • pp.399-410
    • /
    • 2012
  • Due to development of modern medical services and economics, people raised expectation and demand about medical services from previous disease treatment to comprehensive health care covering prevention and health care. Responses of each medical facility to these social needs and the evolution of concept of medicine rapidly occur. The health examination centers are being operated with the purpose of health examination and this trend is reflected on several aspects such as the size of the facilities, function and configuration of space in health examination centers. Thus, health examination centers consisting of various space systems appear, but this trend and interpretations are lacking. Therefore, the purpose of this study is to draw trends of system through analysis of types and its evolved space systematic analysis and establish it. Analysis targets were classified into small, medium and large groups by sizes based on number of space and a total of 12 health examination centers in four for each category were selected. As research methods, functional relationship of space was examined through analysis of type in which segmentalized type tools were applied in local units. The flow diagram was established based on direction turning point and was classified into sub-flow and main-flow in local units and the systems between local units were derived. Finally, the results of this study can be summarized as the following three results. 1) The space connection system of health examination center showed four systems such as circulation, independence, continuation, and network. 2) Local type indicators and global type indicators which were evolved more from limitation of type analysis tools in existing research were derived so that more systematic analysis could be made. 3) Network system is distributed approach system and space for each function is formed around public space.

  • PDF

Shear resistance characteristic and ductility of Y-type perfobond rib shear connector

  • Kim, Sang-Hyo;Park, Se-Jun;Heo, Won-Ho;Jung, Chi-Young
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.497-517
    • /
    • 2015
  • This study evaluates behavior of the Y-type perfobond rib shear connector proposed by Kim et al. (2013). In addition, an empirical shear resistance formula is developed based on push-out tests. Various types of the proposed Y-type perfobond rib shear connectors are examined to evaluate the effects of design variables such as concrete strength, number of transverse rebars, and thickness of rib. It is verified that higher concrete strength increases shear resistance but decreases ductility. Placing transverse rebars significantly increases both the shear resistance and ductility. As the thickness of the ribs increases, the shear resistance increases but the ductility decreases. The experimental results indicate that a Y-type perfobond rib shear connector has higher shear resistance and ductility than the conventional stud shear connector. The effects of the end bearing resistance, resistance by transverse rebars, concrete dowel resistance by holes, and concrete dowel resistance by Y-shape ribs on the shear resistance are estimated empirically based on the push-out test results and the additional push-out test results by Kim et al. (2013). An empirical shear resistance formula is suggested to estimate the shear resistance of a Y-type perfobond shear connector for design purposes. The newly developed shear resistance formula is in reasonable agreement with the experimental results because the average ratio of measured shear resistance to estimated shear resistance is 1.024.

Pseudo-BIPV Style Rooftop-Solar-Plant Implementation for Small Warehouse Case

  • Cha, Jaesang;Cho, Ju Phil
    • International journal of advanced smart convergence
    • /
    • v.11 no.3
    • /
    • pp.187-196
    • /
    • 2022
  • In this paper, we propose an example of designing and constructing a roof-type solar power plant structure equipped with a Pseudo-BIPV (Building-Integrated Photovoltaic) shape suitable for use as a roof of a small warehouse with a sandwich-type panel structure. As the characteristics of the roof-type solar power generation facility to be installed in the small warehouse proposed in this study, the shape of the roof is not a general A type, but a right-angled triangle shape with the slope is designed to face south. We chose a structure in which an inverter for one power plant and a control facility are linked by grouping several roofs of buildings. In addition, the height of the roof structure is less than 20 cm from the floor, and it has a shape similar to that of the BIPV, so it is building-friendly because it is almost in close contact with the roof. At the same time, the roof creates a reflective light source due to the white color. By linking this roof with a double-sided solar panel, we designed it to obtain both the advantage of the roof-friendliness and the advantage of efficiency improvement for the electric power generation based on the double-sided panel. Compared to the existing solar power generation facilities using A-shaped cross-sectional modules, the power generation efficiency of roofs in this case is increased by more than 11%, which we can confirm, through the comparison analysis of monitoring data between power plants in the same area. Therefore, if the roof-type solar structure suitable for the small warehouse we have presented in this paper is used, the facilities of electric power generation is eco-friendly. Further it is easier to obtain facility certification compared to the BIPV, and improved capacity of the power generation can be secured at low material cost. It is believed that the roof-type solar power generation facility we proposed can be usefully used for warehouse or factory-based smart housing. Sensor devices for monitoring, CCTV monitoring, or safety and environment management, operating in connection with the solar power generation facilities, are linked with the Internet of Things (IoT) solution, so they can be monitored and controlled remotely.

Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease

  • Kim, Dae-Hyun;Kim, Hyun Ju;Kim, Sungtae;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.103-113
    • /
    • 2018
  • Purpose: The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. Methods: This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. Results: A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference (P<0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P=0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P=0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. Conclusions: IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

An Investigation on the Ultimate Strength of Duplex Stainless Steel (STS329FLD) Bolted Connections with Two Bolts (2행 1열 듀플렉스계 스테인리스강(STS329FLD) 볼트접합부의 최대내력 조사)

  • An, Sung-Ho;Kim, Geun-Young;Hwang, Bo-Kyung;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.55-63
    • /
    • 2018
  • Recently, the use of duplex stainless steel which with a two-phase microstructure (equal mixture of ferrite and austenite) has been increased in a variety of industrial fields due to higher strength leading to weight saving, greater corrosion resistance(particularly, stress corrosion cracking) and lower price. However, currently, stainless steels are not included in the structural materials of Korean Building Code and corresponding design standards are not specified. In this paper, experimental studies have been performed to investigate the structural behaviors of duplex stainless steel (STS329FLD) bolted connection with two bolts for providing the design data. Main variables are shear connection type (single shear and double shear) and end distance parallel to the direction of applied force. Fracture modes at the final step of test were classified into typical block shear fracture, tensile fracture and curling. Curling occurrence in single shear connection led to ultimate strength drop by up to 20%. Test strengths were compared with those by current design specifications such as AISC/AISI/KBC, EC3 and AIJ and proposed equations by existing studies. For specimens with no curling, Clement & Teh's equation considering the active shear plane provided a higher strength estimation accurancy and for specimens with curling, Kim & Lim's equation considering strength reduction by curling was also overly unconservative to predict the ultimate strength of curled connections.

Evaluation on Structural Performance of Precast Bridge Deck Joint using HSFRC (고강도 강섬유보강콘크리트를 적용한 프리캐스트 바닥판 이음부의 구조성능 평가)

  • Lee, Han-Joo;Chung, Chul-Hun;Shin, Dong-Ho;Park, Se-Jin;Kim, In-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.196-205
    • /
    • 2017
  • In precast deck system, structural performance and serviceability are mostly determined by the connection methods between the precast decks. This study proposes precast deck system with asymmetric ribbed connection details using High Strength Fiber Reinforced Concrete(HSFRC) with filler. To verify the proposed method, the flexural performance experiment was carried out with variation of joint cross section type and splice rebar details. From the test results, regardless of joint details, spliced tensile rebars of specimens were deformed to yielding strain level. Also, all types of specimens resulted in sufficient flexural performance. These test results show that the minimum lap splice length specified in current Korea Highway Bridge Design Code is conservative for precast deck joint using HSFRC. Therefore, splice details can be simplified and joint width can be reduced by using HSFRC with filler between the precast decks, and the proposed precast deck systems can be applied to the connection part of precast decks effectively.

A study on analysis of the Relationship Oral bacteria to dental caries experience in disabled student's: in Gyeong-nam (경남지역 특수학교 학생의 구강내 세균검사에 따른 영구치우식경험률에 관한 연구)

  • Cho, Pyeong-Kyu;Park, Sung-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.4
    • /
    • pp.115-125
    • /
    • 2008
  • The purpose of this study was to examine the relationship between the Dentocult SM and LB scores of students and their DMF rate. The subjects in this study were 134 special school students in south Gyeong-sang province. After they were tested to find out their, they received tooth brushing education and preventive treatment. The test, education and treatment were all conducted from March 17 to April 9, 2008. Their oral state was checked and recorded by using a mirror and explorer, and then the data on oral state were analyzed to their DMFT, DT, FT and MT rates. All the collected data were analyzed with SPSS 15.0 for Windows program, and independent-samples t-test, one-way ANOVA and crosstabs analysis were implemented to see what differences their disability type, gender, Dentocult-SM scores and Dentocult-LB scores made. The findings of the study were as follows: 1. As for connections between disability type and DMFT rate, the students with mental retardation were similar to the other students in that regard. The mentally retarded students had higher DT and FT rates than the other students, and the MT rate of the latter was higher than that of the former. 2. Concerning the relationship of gender to DMFT and DT rates, the girls had larger DMFT and DT rates than the boys, and the FT and MT rates of the boys were higher than those of the girls. 3. As to links between Dentocult SM scores on the tongue and DMFT, the students whose bacteria was mildly activated had the highest DMFT rate, and the students who had a severely activated bacteria had the highest DT and FT rates. Those who had a moderately activated bacteria had the highest MT rate. 4.Regarding the connection of Dentocult SM scores on maxillyright molar to DMFT and DT rates, the students whose bacteria was severely activated had the highest DMFT and DT rates. Those who had no activated bacteria had the largest FT rate, and the students who had a mildly activated bacteria had the highest MT rate. 5.Regarding the connection of Dentocult SM scores on maxillyleft molar to DMFT and DT rates, the students whose bacteria was severely activated had the highest DMFT and DT rates. Those who had no activated bacteria had the largest FT rate, and the students who had a mildly activated bacteria had the largest MT rate. 6. Regarding the connection of Dentocult SM scores on mandibularright molar to DMFT and DT, FT rates, the students whose bacteria was severely activated had the highest DMFT and DT, FT rates. Those who had a moderately activated bacteria had the highest MT rate. 7. Regarding the connection of Dentocult SM scores on mandibularleft molar to DMFT and DT rates, the students whose bacteria was mildly activated had the highest DMFT and DT rates. Those who had no activated bacteria had the largest FT rate, and the students who had a moderately activated bacteria had the highest MT rate. 8. Regarding the connection of Dentocult LB scores to DMFT and DT rates, the students whose bacteria was severely activated had the highest DMFT and DT rates. Those who had no activated bacteria had a moderately FT rate, the students who had a mildly activated bacteria had a mildly MT rate.

  • PDF

A Study on the Improvement in Spatial Planning of Orphanage Facilities (아동양육시설의 공간계획 개선에 관한 연구)

  • Yoo, Myoung-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.1
    • /
    • pp.228-239
    • /
    • 2012
  • This study aims to propose the improvement direction of spatial organization of orphanage facilities by reflecting the international trend of child welfare facilities including 'enhancement of habitability', 'opening to the local community' and 'multi-functionality' on the basis of ideas of 'right of housing' and 'normalization'. Orphanage facilities are evolving from 'facilities' to accommodate unfortunate children to the concept of the 'community-care', and the residential space is also rapidly shifting to 'cottage' type resembling a residential type of ordinary family so as to enhance the self-esteem and relationship. To suggest the future-oriented changeability of current orphanage facilities, the present study conducted a nationwide survey of child welfare facilities and four Visiting researches of cottage type orphanage with different locations to investigate the appropriateness of housing type, organization of common use space, mode of management and facilities criteria. The results of this study are following: 1) For enhancement of habitability it is suggested that cottage type with various plans in the form of ordinary housing is appropriate, that the number of children per cottage is six or so, and that the number of less than two or three children per room is recommended. At the same time the adjustment of facilities criteria, simplified or complex, is suggested to support a similar residence pattern to ordinary home. 2) Specialized programs must be introduced to establish a base of welfare-network for community children according to features of location and a complex management must be sought in the connection with neighboring public facilities. 3) To secure the residential environment and quality of life for children, the concept of a simple playground space by the current facilities criteria must be broken away to reinforce the network of various outdoor spaces closely connected with living space.

  • PDF

Overdentures using newly designed metal ball attachment containing predetermined gap with stress breakers (일정한 간극으로 새롭게 고안된 완압형 볼 어태치먼트를 이용한 피개의치 수복)

  • Yoo, Jin-Joo;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.311-318
    • /
    • 2017
  • Several types of attachments have been used for implant supported and/or retained overdentures. Locator is one of the stud type attachments and it has been generally used. However, the colored matrix is resilient and vulnerable to wear, so frequent post-insertion maintenance is needed. To solve this problem, it is necessary to introduce innovative attachment system. Overdentures using Air Gap attachment (AGA) has improved masticatory function and facial esthetics. AGA is made of metal, so it could be more resistant to wear or friction than the other resilient attachments. Nevertheless, AGA plays a role in stress breakers because it allows movement during denture movement with predetermined gap. In addition, both pre-existing implants and natural teeth were successfully used for connection of AGA. AGA could replace other unsplinted type of attachments. Overdentures using AGA could provide satisfactory result in terms of function, esthetics and retention. However, long term follow up is needed.