• Title/Summary/Keyword: connection type

Search Result 1,444, Processing Time 0.028 seconds

A Study on the relationship in spatial structure of senior Center in Seoul (서울시 노인종합복지관의 공간 구조적 연결 관계에 관한 연구)

  • Kim, Jin-A;Byun, Dae-Joong
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.182-193
    • /
    • 2012
  • The percentage of senior citizens is increasing in Korea and it is expected to become an "aging society". Problems with the elderly are becoming a big concern, such as physical and mental illness, losing their jobs and having difficulties at home. But, the silver generation, as they are being known, has changed a lot these days. With the aid of medical developments, the elderly's lifespan has become longer, making them more independent and active. Senior Welfare Center's are places where the elderly can spend their golden years in comfort, meaningfully. Senior Welfare Center's these days provide many different programs, which naturally lead to an increase in elderly users. With the rise in welfare centers and users, research on the subject also grew. As this topic has only recently become an issue, there were not many spatial structure studies considering elderly movement. Therefore, there should be spatial structure research that considers older users space awareness and how it can be managed effectively. The goal of this study is to present basic resources for providing a comfortable senior welfare center for elders. This will be based on quantitative analysis derived from spatial structure research along with special construction characteristics based on the institution's general plan. As a research method, Senior Welfare Center's will be categorized into corridor type, hall type, and hybrid types which then be reproduced into a j-graph. Based on this, special structure characteristics and connection links will be comprehended. Then the connection link will be analyzed based on the space syntax result calculated from each type's integration, connectivity, control value, and intelligibility. The analysis result shows that Senior Welfare Center j-graph's average arrangement is hybrid>corridor>hall types. Those elders lacking awareness need easily perceivable spatial structure's and hall type's would be the best choice to increase their awareness as it has high articulation. However, hall type's would be difficult to construct with the size increase, so hybrid type would be the next logical solution. Space with relatively high articulation will need to be planned in hybrid type's where rest areas can be created within the halls in the Welfare Center in connection to its corridors.

  • PDF

Analysis on the Shear Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel (U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 전단 거동 분석)

  • Ha, Soo-Kyoung;Son, Guk-Won;Yu, Sung-Yong;Ju, Ho-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.6
    • /
    • pp.18-28
    • /
    • 2015
  • The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of U-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D, agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.

A study of motion characteristics along the connection methods between the floating body and the wave energy convertor (파력발전기의 가동부유체와 본체 사이의 연결방식에 따른 운동특성 연구)

  • Kim, Sung-Soo;Lee, Jong-Hyun;Kang, Dong-Hoon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.10a
    • /
    • pp.17-18
    • /
    • 2014
  • Wave energy generation system is sorted as oscillating water chamber type, over topping device type and wave activating body type. The wave activating body type converts from wave energy to kinetic of the machine one and the power generation amount increases while the motion of a activating body increases. In this paper the wave energy convertor consists of a main body which has a generation system and the activating body. They are connected by a bar type bridge. The twisting moment and angular velocity at a shaft of convertor are calculated when various condition of the incident wave, a diversity of connection methods between the main body and the activating body. It can be used as basic idea for determining the design of wave activating body type convertor.

  • PDF

Characteristic Analysis for Weight Values of Evaluation Items by Traffic Safety Project Type (교통안전사업 유형별 평가항목의 가중치 특성분석)

  • Lee, Heewon;Lee, Jisun
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.147-156
    • /
    • 2018
  • PURPOSES : The purpose of this study is to analyze the characteristics of the weight values of evaluation items by traffic safety project type. METHODS : In general, a large-scale investment in projects such as the traffic safety project requires economic analyses to be performed in advance. However, there is an argument for considering special characteristics of the traffic safety project. Therefore, this study conducted characteristic analysis of the weight values of evaluation items. The analysis consisted of two steps. The first step was hypothesis verification using analysis of variance (ANOVA). In this process, the authors examined whether the weight of evaluation items is the same regardless of the traffic safety project type. Based on the first step's results, the authors proceeded to the second step. The objective of this step was to analyze how different the weight values are by traffic safety project type using an analytic hierarchy process. RESULTS : According to the ANOVA test results, the benefit to cost ratios have different weight values based on traffic safety project type at the 0.01 significance level. The policy evaluation items, such as the plans connection, resident opinion, and regional equity, also showed the same results except that the result for the related plans connection was statistically significant at the 0.05 level. Based on the first step's result, the AHP analysis in the second step showed that the traffic safety projects for vulnerable users and pedestrians have very low weight values in economic evaluation factors compared with other safety project types. The weight values for vulnerable users and pedestrians were 0.29 and 0.26, respectively, in economic evaluation items. On the other hand, the weight values for other safety project types were around 0.6. Among the policy evaluation items, resident opinion showed a higher weight value than other factors, such as connection and regional equity items. CONCLUSIONS : The social and economic impact of a traffic safety project varies by project type and project characteristics. Although the economic approach is overarching and a reasonable methodology is applied for large-scale projects, it should be noted that the safety issue, especially for transportation of vulnerable uses, requires a non-economical approach. Based on the analysis results, this study suggests that the priority of the projects should be determined by separating them into independent assessment groups depending on their characteristics.

Total Correction of Mixed Type Total Anomalous Pulmonary Venous Return 1 Case (혼합형 총폐정맥환류이상 수술치험 1례)

  • 편승환;서정욱
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.213-218
    • /
    • 1996
  • Total anomalous pulmonary venous return (TAPVR) is very rare congenital heart disease. 25-year old male was admitted our hospital with dyspnea, headache and syncope as chief complaint. He was confirmed as mixed type TAPVR by echocardiography and cardiac catheterization. In this case, mixed type TAPVR was consisted with supracardiac type connection of left pulmonary vein and cardiac type of right pulmonary vein. Supracardiac type of left pulmonary common channel was anastomosed to the left auricular appendage during total cardiopulmonary bypass with fibrillating heart. Cardiac type of right pulmonary vein was operated during moderate hypothermia and aortic cross clamping. Coronary sinus septum was incised into ASD and closed with Gore-Tex patch so that right pulmonary blood flow directed to the left atrium. The patient's post-operative course was uneventful.

  • PDF

Numerical study on tunnel design for securing stability at connection between submerged floating tunnel and bored tunnel (수중터널 지반 접속부 안정성 확보를 위한 터널 설계에 대한 수치해석적 연구)

  • Kang, Seok-Jun;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.77-89
    • /
    • 2020
  • Submerged floating tunnel (SFT) is a type of tunnel that allows tunnel segments to float underwater by buoyancy, and is being actively studied in recent years. When the submerged floating tunnel is connected to the ground, the tunnel and the bored tunnel inside the ground must be connected. There is risk that the stress will be concentrated at the connection between the two tunnels due to the different constraints and behavior of the two tunnels. Therefore, special design and construction methods should be applied to ensure the stability around the connection. However, previous studies on the stability at the connection site have not been sufficiently carried out, so study on the basic stage of the stability at connection site are necessary. In this study, numerical analysis simulating the connection between submerged floating tunnel and the bored tunnel confirmed that the shear strain concentration occurred in the ground around the connection, and it was analyzed that the structural factors can be handled during construction to have effects on the stability of the ground around the connection. Numerical results show that the risks from disproportionate displacements in the two tunnels can be mitigated through the construction of grouting material and joint design. Although the results from this study are qualitative results, it is expected that it will contribute to the determination of structural factors and risk areas that should be considered in the design of connections between the submerged floating tunnel and bored tunnel in the future studies.

FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS WITH INTERNAL CONNECTION BETWEEN THE IMPLANT AND THE ABUTMENT (임플란트와 지대주간 내측 연결을 갖는 임플란트 보철의 유한요소 응력분석)

  • Ahn, Jong-Kwan;Kay, Kee-Sung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.356-372
    • /
    • 2004
  • Statement of problom: In the internal connection system the loading transfer mechanism within the inner surface of the implant and also the stress distribution occuring to the mandible can be changed according to the abutment form. Therefore it is thought to be imperative to study the difference of the stress distribution occuring at the mandible according to the abutment form. Purpose: The purpose of this study was to assess the loading distributing characteristics of 3 implant systems with internal connection under vertical and inclined loading using finite element analysis. Material and method: Three finite element models were designed according to the type of internal connection of ITI(model 1), Friadent(model 2), and Bicon(model 3) respectively. This study simulated loads of 200N in a vertical direction (A), a $15^{\circ}$ inward inclined direction (B), and a $30^{\circ}$ outward inclined direction (C). Result: The following results have been made based on this numeric simulations. 1. The greatest stress showed in the loading condition C of the inclined load with outside point from the centric cusp tip. 2. Without regard to the loading condition, the magnitudes of the stresses taken at the supporting bone, the implant fixture, and the abutment were greater in the order of model 2, model 1, and model 3. 3. Without regard to the loading condition, greater stress was concentrated at the cortical bone contacting the upper part of the implant fixture, and lower stress was taken at the cancellous bone. 4. The stress of the implant fixture was usually widely distributed along the inner surface of the implant fixture contacting the abutment post. 5. The stress distribution pattern of the abutment showed that the great stress was usually concentrated at the neck of the abutment and the abutment post, and the stress was also distributed toward the lower part of the abutment post in case of the loading condition B, C of the inclined load. 6. In case of the loading condition B, C of the inclined load, the maximum von Misess stress at the whole was taken at the implant fixture both in the model 1 and model 2, and at the abutment in the model 3. 7. The stress was inclined to be distributed from abutment post to fixture in case of the internal connection system. Conclusion: The internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, and the abutment according to the abutment connection form had differenence among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the a butment post.

Fatigue Capacity Evaluation of the Girder-Abutment Connection for the Steel-Concrete Composite Rigid-Frame Bridge Integrated with PS Bar (PS 강봉으로 일체화된 강합성 라멘교의 거더-교대 접합부에 대한 피로 성능 평가)

  • Ahn, Young-Soo;Oh, Min-Ho;Chung, Jee-Seung;Lee, Sang-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.249-258
    • /
    • 2012
  • Integral and rigid frame bridges have advantages in bridge maintenance and structural efficiency by eliminating expansion joints and bridge supports. However, the detail of typical girder-abutment connection is rather complex and increases construction cost depending on construction detail. For the purpose of compensating disadvantages such as complexity and additional cost, a new type of bridge is proposed in this study, which improves the efficiency of construction by simplifying the construction detail of girder-abutment connection. The proposed bridge has the connection detail of steel girder and abutment integrated by prestressed PS bar installed in the connection. In this study, finite element analysis and fatigue load test are conducted to evaluate the fatigue capacity of the proposed girder-abutment connection. The results of the finite element analysis revealed that the possibility of the fatigue damage in the girder-abutment connection is very low. The results of the fatigue load test verified that the integrity of the girder and abutment connection is maintained after 2,000,000 cycles of fatigue loading.

Seismic response and energy dissipation in partially restrained and fully restrained steel frames: An analytical study

  • Reyes-Salazar, Alfredo;Haldar, Achintya
    • Steel and Composite Structures
    • /
    • v.1 no.4
    • /
    • pp.459-480
    • /
    • 2001
  • The damage suffered by steel structures during the Northridge (1994) and Kobe (1995) earthquakes indicates that the fully restrained (FR) connections in steel frames did not behave as expected. Consequently, researchers began studying other possibilities, including making the connections more flexible, to reduce the risk of damage from seismic loading. Recent experimental and analytical investigations pointed out that the seismic response of steel frames with partially restrained (PR) connections might be superior to that of similar frames with FR connections since the energy dissipation at PR connections could be significant. This beneficial effect has not yet been fully quantified analytically. Thus, the dissipation of energy at PR connections needs to be considered in analytical evaluations, in addition to the dissipation of energy due to viscous damping and at plastic hinges (if they form). An algorithm is developed and verified by the authors to estimate the nonlinear time-domain dynamic response of steel frames with PR connections. The verified algorithm is then used to quantify the major sources of energy dissipation and their effect on the overall structural response in terms of the maximum base shear and the maximum top displacement. The results indicate that the dissipation of energy at PR connections is comparable to that dissipated by viscous damping and at plastic hinges. In general, the maximum total base shear significantly increases with an increase in the connection stiffness. On the other hand, the maximum top lateral displacement $U_{max}$ does not always increase as the connection stiffness decreases. Energy dissipation is considerably influenced by the stiffness of a connection, defined in terms of the T ratio, i.e., the ratio of the moment the connection would have to carry according to beam line theory (Disque 1964) and the fixed end moment of the girder. A connection with a T ratio of at least 0.9 is considered to be fully restrained. The energy dissipation behavior may be quite different for a frame with FR connections with a T ratio of 1.0 compared to when the T ratio is 0.9. Thus, for nonlinear seismic analysis, a T ratio of at least 0.9 should not be considered to be an FR connection. The study quantitatively confirms the general observations made in experimental results for frames with PR connections. Proper consideration of the PR connection stiffness and other dynamic properties are essential to predict dynamic behavior, no matter how difficult the analysis procedure becomes. Any simplified approach may need to be calibrated using this type of detailed analytical study.

Fire Mechanism in Power Connection Points of Outlets and Suggestion of a New Identification Method (콘센트 전원 접속구 화재 발생 메커니즘 고찰과 새로운 감식 방법 제시)

  • Park, Jin-Young;Bang, Sun-Bae;Eun, Hee-Rim;Oh, Se-Hyeok;Lee, Yoo-Bin;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 2020
  • Most outlet fires occur around plug pins and plug pin receivers. However, no research has been conducted on ignitions at power connection points. This study confirms the possibility of ignition after incomplete connection, using a stranded wire, to the power connection point of an outlet. The experiment was divided into basic and reproducing experiments. The basic experiment confirmed the possibility of ignition according to the number of wire strands connected to the power connection point, and it identified the characteristics of the residue after the fire. In the reproducing experiment, lamps, vacuum cleaners, and heaters were connected to an outlet to check if the ignition at the connection advanced into a fire. The fire advanced due to the heat and arc generated at the connection point, and partial losses were identified in the U-type holder and clip. Accordingly, the results demonstrate that a fire may occur when the stranded wire is incompletely connected to the outlet. Moreover, it was confirmed that the cause of a fire can be determined based on the characteristics of the residue.