• Title/Summary/Keyword: connection method

Search Result 2,943, Processing Time 0.032 seconds

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.10 no.3
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

Experimental study of beam-column connections with web opening in a low-rise steel frame

  • Wang, Xiuli;Yin, Zhanzhong;Li, Qingfu;Shen, Shizhao
    • Structural Engineering and Mechanics
    • /
    • v.26 no.3
    • /
    • pp.263-276
    • /
    • 2007
  • Steel frame structures have been widely used in multi-storey and high-rise buildings and the connections in these structures are critical. In the Northridge and Kobe Earthquake, beam-column connections suffered damage due to brittle fracture. According to seismic design codes, ductility of the beam to column connection is also necessary. A study on the behavior of a beam to column connection with the aim of improving ductility as well as preventing brittle failure was carried out. In order to control the position of a plastic hinge on the beam, a connection with a hole in the beam web was developed. Five specimens with different parameters under cyclic load were assessed. The results are presented in terms of the stress distribution of the beam, hysteretic behavior, and ultimate capacity. Furthermore, the finite element method was also used to analyze the model, and the results were compared with those obtained from the experiment. It is shown from the analysis and experimental results that this type of connection is effective in terms of improving ductility for a beam to column connection in low-rise buildings.

Seismic performance of beam-to- SST column connection with external diaphragm

  • Rong, Bin;Yin, Shuhao;Zhang, Ruoyu;Wang, Lei;Yang, Ziheng;Li, Hongtao;Wan, Wenyu
    • Steel and Composite Structures
    • /
    • v.37 no.6
    • /
    • pp.633-647
    • /
    • 2020
  • This paper aims to study the seismic performance of external diaphragm connection between SST (square steel tube) column and H-shaped beam through experimental and analytical study involving finite element (FE) method and theoretical analysis. In the experimental study, three external diaphragm connection specimens with weak panel zone were tested under axial pressure on the top of the column and antisymmetric cyclic loads at the beam end to investigate the seismic performance of the panel zone. The hysteretic behavior, failure mode, stiffness and ductility of the specimens were discussed. Key point to be explored was the influence of the thickness of the steel tube flange on the shear capacity of the specimens. In the analytical study, three simplified FE models were developed to simulate the seismic behavior of the specimens for further analysis on the influence of steel tube flange. Finally, four existing calculation formulas for the shear capacity of the external diaphragm connection were evaluated through comparisons with the results of experiments and FE analysis, and application suggestions were put forward.

Friction-based beam-to-column connection for low-damage RC frames with hybrid trussed beams

  • Colajanni, Piero;Pagnotta, Salvatore
    • Steel and Composite Structures
    • /
    • v.45 no.2
    • /
    • pp.231-248
    • /
    • 2022
  • Hybrid Steel-Trussed Concrete Beam (HSTCB) is structural typology suitable for light industrialization. HSTCBs usually cover long span with small depths, which lead to significant amount of longitudinal rebars. The latter make beam-column joints more prone to damage due to earthquake-induced cyclic actions. This phenomenon can be avoided using friction-based BCCs. Friction devices at Beam-to-Column Connections (BCCs) have become promising solutions to reduce the damage experienced by structural members during severe earthquakes. Few solutions have been developed for cast-in-place Reinforced Concrete (RC) and steel-concrete composite Moment Resisting Frames (MRFs), because of the difficulty of designing cost-effective damage-proof connections. This paper proposes a friction-based BCC for RC MRFs made with HSTCBs. Firstly, the proposed connection is described, and its innovative characteristics are emphasized. Secondly, the design method of the connection is outlined. A detailed 3D FE model representative of a beam-column joint fitted with the proposed connection is developed. Several monotonic and cyclic analyses are performed, investigating different design moment values. Lastly, the numerical results are discussed, which demonstrate the efficiency of the proposed solution in preventing damage to RC members, and in ensuring satisfactory dissipative capacity.

Dynamic characteristics analysis of partial-interaction composite continuous beams

  • Fang, Genshen;Wang, Jingquan;Li, Shuai;Zhang, Shubin
    • Steel and Composite Structures
    • /
    • v.21 no.1
    • /
    • pp.195-216
    • /
    • 2016
  • The dynamic characteristics of continuous steel-concrete composite beams considering the effect of interlayer slip were investigated based on Euler Bernoulli's beam theory. A simplified calculation model was presented, in which the Mode Stiffness Matrix (MSM) was developed. The natural frequencies and modes of partial-interaction composite continuous beams can be calculated accurately and easily by the use of MSM. Proceeding from the present method, the natural frequencies of two-span steel-concrete composite continuous beams with different span-ratios (0.53, 0.73, 0.85, 1) and different shear connection stiffnesses on the interface are calculated. The influence pattern of interfacial stiffness on bending vibration frequency was found. With the decrease of shear connection stiffness on the interface, the flexural vibration frequencies decrease obviously. And the influence on low order modes is more obvious while the reduction degree of high order is more sizeable. The real natural frequencies of partial-interaction continuous beams commonly used could have a 20% to 40% reduction compared with the fully-interaction ones. Furthermore, the reduction-ratios of natural frequencies for different span-ratios two-span composite beams with uniform shear connection stiffnesses are totally the same. The span-ratio mainly impacts on the mode shape. Four kinds of shear connection stiffnesses of steel-concrete composite continuous beams are calculated and compared with the experimental data and the FEM results. The calculated results using the proposed method agree well with the experimental and FEM ones on the low order modes which mainly determine the vibration properties.

Re-Interpreting the Descartes's Perspectives on the Connection of Algebra and Geometry (대수와 기하의 연결에 관한 Descartes의 관점 재조명 연구)

  • Ban, Eun Seob;Shin, Jaehong;Lew, Hee Chan
    • Journal of Educational Research in Mathematics
    • /
    • v.26 no.4
    • /
    • pp.715-730
    • /
    • 2016
  • The purpose of this study is to analyze Descartes's point of view on the mathematical connection of algebra and geometry which help comprehend the traditional frame with a new perspective in order to access to unsolved problems and provide useful pedagogical implications in school mathematics. To achieve the goal, researchers have historically reviewed the fundamental principle and development method's feature of analytic geometry, which stands on the basis of mathematical connection between algebra and geometry. In addition we have considered the significance of geometric solving of equations in terms of analytic geometry by analyzing related preceding researches and modern trends of mathematics education curriculum. These efforts could allow us to have discussed on some opportunities to get insight about mathematical connection of algebra and geometry via geometric approaches for solving equations using the intersection of curves represented on coordinates plane. Furthermore, we could finally provide the method and its pedagogical implications for interpreting geometric approaches to cubic equations utilizing intersection of conic sections in the process of inquiring, solving and reflecting stages.

Analysis on Connection of Information Infra for Efficient Ubiquitous-service Realization (효율적인 u-서비스 구현을 위한 정보 인프라 연계성 분석)

  • Choi, Pill-Soon;Kang, Joon-Mook;Park, Joon-Kyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.5
    • /
    • pp.497-507
    • /
    • 2011
  • Ubiquitous city which was appeared since 2006 is defined as "The city provided the ubiquitous city service anytime and anywhere using ubiquitous urban infrastructure to improve the city's competitiveness and quality of life" under ubiquitous city construction law. To realize the ubiquitous city, the city has to be constructed efficiently based on the spatial information. And connection of information achieve effective synergy. In this study, applied multilateral analysis to spatial information and administrative information to implement u-service focused on MACCA(Multifunctional Administrative City Construction Agency). Study about main function and product data with connection process of Korean Land Spatialization System and administrative information System was performed. Also, details of u-service and method of acquiring necessary data were derived. In Addition, the information connection possibility for efficient u-service realization was suggested by linkage analysis method to utilize the related information infrastructure jointly.

A Study on Teaching Continuous Probability Distribution in Terms of Mathematical Connection (수학적 연결성을 고려한 연속확률분포단원의 지도방안 연구)

  • Hwang, Suk-Geun;Yoon, Jeong-Ho
    • School Mathematics
    • /
    • v.13 no.3
    • /
    • pp.423-446
    • /
    • 2011
  • In school mathematics, concepts of definite integral and integration by substitution have mathematical connection with introduction of probability density function, expectation of continuous random variable, and standardization of normal distribution. However, we have difficulty in finding mathematical connection between integration and continuous probability distribution in the curriculum manual, 13 kinds of 'Basic Calculus and Statistics' and 10 kinds of 'Integration and Statistics' authorized textbooks, and activity books applied to the revised curriculum. Therefore, the purpose of this study is to provide a teaching method connected with mathematical concepts of integral in regard to three concepts in continuous probability distribution chapter-introduction of probability density function, expectation of continuous random variable, and standardization of normal distribution. To find mathematical connection between these three concepts and integral, we analyze a survey of student, the revised curriculum manual, authorized textbooks, and activity books as well as 13 domestic and 22 international statistics (or probability) books. Developed teaching method was applied to actual classes after discussion with a professional group. Through these steps, we propose the result by making suggestions to revise curriculum or change the contents of textbook.

  • PDF

Reversed Cyclic Loading Test of Post-Tensioned Precast Concrete Beam-Column Connections with 2400MPa Prestressing Strands (2400MPa 긴장재가 적용된 포스트텐션 프리캐스트 콘크리트 보-기둥 접합부의 반복가력실험)

  • Hwang, Jin-Ha;Choi, Seung-Ho;Lee, Deuck Hang;Kim, Kang Su;Woo, Woon Tack
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.45-52
    • /
    • 2017
  • The precast concrete (PC) method has many advantages in fast construction, quality control, etc. In domestic construction market, however, its application has been quite limited because of the concerns about structural integrity and seismic performances due to the discrete connections between precast concrete members. By applying the post-tensioning method, the precast beam-column connection can be well tightened, allowing improved structural integrity, and proper seismic performances can be also achieved. In this study, reversed cyclic tests have been conducted on the beam-column connection specimens, where the test variables included the compressive strength of grouting mortar and the tensile strengths of prestressing strands, based on which their seismic performances have been examined in detail. The post-tensioned PC beam-column connections showed good seismic performances comparable to that of the monolithic reinforced concrete connection specimen. When 2400 MPa prestressing strands are applied to the beam-column connection, it is preferable to adjust the prestress level similar to that applied for the 1860 MPa prestressing strands to avoid premature local crushing failures at the beam-column connections.

Study on Multi Parameter Measurement and Analysis of Distribution High Voltage Cable Connection Part (배전용 특고압 케이블 접속재의 다변수 측정 분석 연구)

  • Song, Ki-Hong;Bae, Young-Chul;Kim, Yi-Gon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.53-60
    • /
    • 2021
  • High voltage CV cables have been widely installed underground due to their convenience and urban aesthetics. However, cable accidents have occurred frequently owing to poor construction and natural degradations. This paper proposes the method to measure the multi parameter measurement for optimum diagnostics of high voltage cable connection parts and verifies its technical usefulness. This measurement is intended to diagnose degradations of cable connection parts by using simultaneous vibration and thermography as well as partial discharge(PD). The experiment in a shielded laboratory was carried out to verify the usefulness of the multi parameter measurement. The experiment defined the degradation of the cable connection part as 12 types, and produced each degradation sample. As a result of experiment, it was possible to check the correlation of vibration signals with regard to progress in some defects. In the case of thermography, the coherence with regard to the progress of some defects was found. We figure that the proposed method would be useful also in the noise environment.