• 제목/요약/키워드: cone model

검색결과 371건 처리시간 0.026초

복합 모델을 이용한 연료 인젝터의 분무 미립화 모델링 (Modeling of Spray Atomization of Fuel Injector Using Hybrid Model)

  • 박성욱;김형준;류열;이창식
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.27-33
    • /
    • 2002
  • This paper presents the comparison of prediction accuracy of hybrid models. To obtain the experimental results fur comparing with the numerical results, the macroscopic and microscopic structures of the hollow-cone spray such as spray development process, spray penetration and the distribution of mean droplet size are investigated by using a shadowgraph technique and phase Doppler particle analyzer. Also, the numerical researches using various hybrid models are performed. LISA model and WAVE model are used for the primary breakup, and TAB, DDB, and RT model are used for the secondary breakup.

Quantitative Evaluation of the Mode of Microtubule Transport in Xenopus Neurons

  • Kim, Taeyong;Chang, Sunghoe
    • Molecules and Cells
    • /
    • 제21권1호
    • /
    • pp.76-81
    • /
    • 2006
  • Tubulin is synthesized in the cell body and must be delivered to the axon to support axonal growth. However, the exact form in which these proteins, in particular tubulin, move within the axon remains contentious. According to the "polymer transport model", tubulin is transported in the form of microtubules. In an alternative hypothesis, the "short oligomer transport model", tubulin is added to existing, stationary microtubules along the axon. In this study, we measured the translocation of microtubule plus ends in soma segments, the middle of axonal shafts and the growth cone areas, by expressing GFP-EB3 in cultured Xenopus embryonic spinal neurons. We found that none of the microtubules in the three compartments were transported rapidly as would be expected from the polymer transport model. These results suggest that microtubules are stationary in most segments of the axon, thus supporting the model according to which tubulin is transported in nonpolymeric form in rapidly growing Xenopus neurons.

Model test and numerical simulation on the bearing mechanism of tunnel-type anchorage

  • Li, Yujie;Luo, Rong;Zhang, Qihua;Xiao, Guoqiang;Zhou, Liming;Zhang, Yuting
    • Geomechanics and Engineering
    • /
    • 제12권1호
    • /
    • pp.139-160
    • /
    • 2017
  • The bearing mechanism of tunnel-type anchorage (TTA) for suspension bridges is studied. Model tests are conducted using different shapes of plug bodies, which are circular column shape and circular truncated cone shape. The results show that the plug body of the latter shape possesses much larger bearing capacity, namely 4.48 times at elastic deformation stage and 4.54 times at failure stage compared to the former shape. Numerical simulation is then conducted to understand the mechanical and structural responses of plug body and surrounding rock mass. The mechanical parameters of the surrounding rock mass are firstly back-analyzed based on the monitoring data. The calculation laws of deformation and equivalent plastic strain show that the numerical simulation results are rational and provide subsequent mechanism analysis with an established basis. Afterwards, the bearing mechanism of TTA is studied. It is concluded that the plug body of circular truncated cone shape is able to take advantage of the material strength of the surrounding rock mass, which greatly enhances its bearing capacity. The ultimate bearing capacity of TTA, therefore, is concluded to be determined by the material strength of surrounding rock mass. Finally, recommendations for TTA design are proposed and discussed.

Recording natural head position using an accelerometer and reconstruction from computed tomographic images

  • Park, Il Kyung;Lee, Keun Young;Jeong, Yeong Kon;Kim, Rae Hyong;Kwon, Dae Gun;Yeon, Sunghee;Kwon, Kyung-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권4호
    • /
    • pp.256-261
    • /
    • 2017
  • Objectives: The concept of natural head position (NHP) was first introduced by Broca in 1862, and was described as a person's stable physiologic position "when a man is standing and his visual axis is horizontal." NHP has been used routinely for clinical examination; however, a patient's head position is random during cone-beam computed tomography (CBCT) acquisition. To solve this problem, we developed an accelerometer to record patients' NHP and reproduce them for CBCT images. In this study, we also tested the accuracy and reproducibility of our accelerometer. Materials and Methods: A total of 15 subjects participated in this study. We invented an accelerometer that measured acceleration on three axes and that could record roll and pitch calculations. Recorded roll and pitch data for each NHP were applied to a reoriented virtual image using three-dimensional (3D) imaging software. The data between the 3D models and the clinical photos were statistically analyzed side by side. Paired t-tests were used to statistically analyze the measurements. Results: The average difference in the angles between the clinical photograph and the 3D model was $0.04^{\circ}$ for roll and $0.29^{\circ}$ for pitch. The paired t-tests for the roll data (P=0.781) and the pitch data (P=0.169) showed no significant difference between the clinical photographs and the 3D model (P>0.05). Conclusion: By overcoming the limitations of previous NHP-recording techniques, our new method can accurately record patient NHP in a time-efficient manner. Our method can also accurately transfer the NHP to a 3D virtual model.

실내모형실험을 통한 인홀형 탄성파콘 시험의 적용성 분석 (A Pilot Study of Inhole Type CPTu from Model Tests)

  • 장인성;정민재;권오순;목영진
    • 대한토목학회논문집
    • /
    • 제28권2C호
    • /
    • pp.95-103
    • /
    • 2008
  • 탄성파 피에조콘 관입시험(Seismic piezocone penetration test, SCPTu)은 콘 관입 저항값과 간극수압 거동 특성 외에도 지반의 동적 특성을 측정할 수 있는 시험법이지만, 해상 조사의 경우 탄성파를 일으키는 발진(Source) 장치를 설치하기가 상당히 힘들기 때문에 SCPTu를 이용하여 해양 지반에 대한 동적 물성치를 파악하는데 어려움이 있다. 따라서 해양 지반의 동적 물성치 파악을 위하여 벤더 엘리먼트를 이용한 인홀형 탄성파 탐사콘(Inhole type CPTu)을 개발하였는데, 이는 콘 롯드(rod) 내부에 발진기(Source)와 수진기(Receiver)를 내재하고 있기 때문에 외부의 부가적인 발진기가 필요 없어 육상 뿐만 아니라 해상에서도 충분히 활용할 수 있다. 이번 연구에서는 인홀형 탄성파콘의 적용성을 분석하기 위해 카올리나이트를 활용한 실내 모형 토조실험을 수행하였는데, 카올리나이트 지반의 전단파 속도를 시간에 따라 측정하였고, 또한 발진부와 수진부 사이의 거리를 다양하게 바꿔가면서 발진기와 수진기가 설치될 때 발생하는 지반 교란의 영향을 검토하였다.

Position of the hyoid bone and its correlation with airway dimensions in different classes of skeletal malocclusion using cone-beam computed tomography

  • Shokri, Abbas;Mollabashi, Vahid;Zahedi, Foozie;Tapak, Leili
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.105-115
    • /
    • 2020
  • Purpose: This study investigated the position of the hyoid bone and its relationship with airway dimensions in different skeletal malocclusion classes using cone-beam computed tomography (CBCT). Materials and Methods: CBCT scans of 180 participants were categorized based on the A point-nasion-B point angle into class I, class II, and class III malocclusions. Eight linear and 2 angular hyoid parameters(H-C3, H-EB, H-PNS, H-Me, H-X, H-Y, H-[C3-Me], C3-Me, H-S-Ba, and H-N-S) were measured. A 3-dimensional airway model was designed to measure the minimum cross-sectional area, volume, and total and upper airway length. The mean crosssectional area, morphology, and location of the airway were also evaluated. Data were analyzed using analysis of variance and the Pearson correlation test, with P values <0.05 indicating statistical significance. Results: The mean airway volume differed significantly among the malocclusion classes(P<0.05). The smallest and largest volumes were noted in class II (2107.8±844.7 ㎣) and class III (2826.6±2505.3 ㎣), respectively. The means of most hyoid parameters (C3-Me, C3-H, H-Eb, H-Me, H-S-Ba, H-N-S, and H-PNS) differed significantly among the malocclusion classes. In all classes, H-Eb was correlated with the minimum cross-sectional area and airway morphology, and H-PNS was correlated with total airway length. A significant correlation was also noted between H-Y and total airway length in class II and III malocclusions and between H-Y and upper airway length in class I malocclusions. Conclusion: The position of the hyoid bone was associated with airway dimensions and should be considered during orthognathic surgery due to the risk of airway obstruction.

Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

  • Campello, Andrea Fagundes;Goncalves, Lucio Souza;Guedes, Fabio Ribeiro;Marques, Fabio Vidal
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.25-31
    • /
    • 2017
  • Purpose: The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods: An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chisquare test. Results: The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions(P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion: CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

Preoperative imaging of the inferior alveolar nerve canal by cone-beam computed tomography and 1-year neurosensory recovery following mandibular setback through bilateral sagittal split ramus osteotomy: a randomized clinical trial

  • Hassani, Ali;Rakhshan, Vahid;Hassani, Mohammad;Aghdam, Hamidreza Mahaseni
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권1호
    • /
    • pp.41-48
    • /
    • 2020
  • Objectives: One of the most common complications of bilateral sagittal split ramus osteotomy (BSSRO) is neurosensory impairment of the inferior alveolar nerve (IAN). Accurate preoperative determination of the position of the IAN canal within the mandible using cone-beam computed tomography (CBCT) is recommended to prevent IAN dysfunction during BSSRO and facilitate neurosensory improvement after BSSRO. Materials and Methods: This randomized clinical trial consisted of 86 surgical sites in 43 patients (30 females and 13 males), including 21 cases (42 sides) and 22 controls (44 sides). Panoramic and lateral cephalographs were obtained from all patients. In the experimental group, CBCT was also performed from both sides of the ramus and mandibular body. Neurosensory function of the IAN was subjectively assessed using a 5-point scale preoperatively and 7 days, 1 month, 3 months, 6 months, and 12 months post-surgery. Data were analyzed using Fisher's test, Spearman's test, t-test, linear mixed-model regression, and repeated-measures ANCOVA (α=0.05, 0.01). Results: Mean sensory scores in the control group were 1.57, 2.61, 3.34, 3.73, and 4.20 over one year and were 1.69, 3.00, 3.60, 4.19, and 4.48 in the CBCT group. Significant effects were detected for CBCT intervention (P=0.002) and jaw side (P=0.003) but not for age (P=0.617) or displacement extent (P=0.122). Conclusion: Preoperative use of CBCT may help surgeons to practice more conservative surgery. Neurosensory deficits might heal faster on the right side.

Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study

  • Dalili, Zahra;Taramsari, Mehran;Mehr, Seyed Zoheir Mousavi;Salamat, Fatemeh
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.19-24
    • /
    • 2012
  • Purpose : Field of view and voxel resolution of cone beam computed tomography (CBCT) might affect the diagnostic capability. This study was performed to compare between the standard and HiRes zoom modes in the diagnosis of external root resorption (ERR) using CBCT. Materials and Methods : Sixty three small cavities (0.25 mm depth and 0.5 mm diameter) were simulated on the buccal, lingual, and proximal surfaces at three different levels of 16 roots of teeth. After covering the root with nail varnish, the roots were inserted in the sockets and the model was placed in a water-containing lacuna. CBCT scans were taken in both standard and HiRes zoom modes using NewTom VG (QR srl Company, Verona, Italy). Then, an observer assessed the images to determine the presence or absence of the cavities. This process was repeated by increasing the size and depth of cavities to 0.5 mm depth and 1 mm diameter. Data were analyzed by McNemar test. The sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratio in evaluation of the simulated cavities were calculated. Results : There was a significant difference between the two imaging modes in diagnosing the shallow cavities (p=0.02).The sensitivity of the standard zoom in detecting the shallow cavities was lower than that of the HiRes zoom. The likelihood ratio of the HiRes zoom was higher in the diagnosis of both cavity types. Conclusion : This study suggested that a smaller voxel size in the HiRes zoom mode of CBCT is preferred for diagnosis of ERR.

목재 가연물의 연소 시 생성되는 탄화가 열분해에 미치는 영향 (Effects of Char Produced from Burning Wood Combustibles on Thermal Pyrolysis)

  • 홍터기;류명호;이종원;박설현
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.7-12
    • /
    • 2019
  • 목재 연료의 연소 시 생성되는 탄화가 열분해 과정에 미치는 영향을 고찰해 보기 위해서 ISO 5660-1 콘칼로리미터 실험을 수행하였고 Fire dynamics simulator (FDS) 전산해석 결과와 비교 분석하였다. 목재 연료로는 건축자재, 가구재 등에 대표적으로 사용되는 Douglas-fir를 사용하였다. Douglas-fir 연소 시 측정된 열방출률은 FDS 전산해석을 통해 예측한 결과와 비교적 잘 일치하였지만 탄화 층의 표면반응을 고려하지 않는 FDS 전산해석 모델은 훈소과정에서 지속적으로 방출되는 열을 예측하지 못하였다. 그럼에도 불구하고 FDS 전산해석을 통해 탄화 층은 가연물에 열장벽을 형성하여 내부로의 열전달을 방해하고 열적 두께를 두껍게 하여 열분해율을 감소시키는 것을 확인하였다.