• Title/Summary/Keyword: conduction model

Search Result 519, Processing Time 0.028 seconds

Current-Voltage Characterization of Silicon Quantum Dot Solar Cells

  • Kim, Dong-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.143-145
    • /
    • 2009
  • The electrical and photovoltaic properties of single junction silicon quantum dot solar cells are investigated. A prototype solar cell with an effective area of 4.7 $mm^2$ showed an open circuit voltage of 394 mV and short circuit current density of 0.062 $mA/cm^2$. A diode model with series and shunt resistances has been applied to characterize the dark current-voltage data. The photocurrent of the quantum-dot solar cell was found to be strongly dependent on the applied voltage bias, which can be understood by consideration of the conduction mechanism of the activated carriers in the quantum dot imbedded material.

Trapezoidal Fin Analysis by the 3-D Analytical Method (3차원 해석적 방법에 의한 사다리꼴 휜 해석)

  • 이성주;강형석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.388-397
    • /
    • 2000
  • Comparison of the heat conduction into a trapezoidal fin and the heat loss from the fin by convection is made in this study Also, the ratio of heat loss from each surface to the total heat loss and the temperature distribution are analyzed using a 3-D analytical method. A trapezoidal fin whose tip height is half the root height is chosen as the model. The results show that the heat transfer rates from the tip and from both sides are comparable with each other as the non-dimensional width and length vary while the heat transfer rate from the bottom and top is dominant.

  • PDF

A Study on the Yearly Thermal Environmental Characteristics in Underground Space (지하거주공간의 연간 열환경에 관한 연구)

  • Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.27-33
    • /
    • 1998
  • The room temperature and air conditioning load in the underground space have been investigated numerically by the unsteady heat conduction equation. The model room has 3 m in height and 10 m in width, and it's position in the underground depth are 0.5 m to 5 m. When the room was located around surface, the room temperatures were strongly influenced by the atmosphere. But the underground depth is more than 2 m, the yearly temperature amplitude was small and the temperature phase was delayed. Up to 5 m of the depth, the cooling and heating load was decreased rapidly, but over 10 m of the depth, the air conditioning load was constant.

  • PDF

Modeling and Analysis of Active-Clamp, Full-Bridge Boost Converter (능동 클램프 풀브릿지 부스트 컨버터에 대한 모델링 및 분석)

  • Kim Marn-Go
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.610-614
    • /
    • 2004
  • Recently, an active-clamp, full-bridge boost converter has been actively studied for high-power applications such as power factor correction and battery discharger. However, DC and AC modeling for this converter has not conquered. In this paper, a DC and small-signal AC modeling for the active-clamp, full-bridge boost converter is described. Based on the operation principle, the ac part of the converter can be replaced by a do counterpart. Then, a conceptual equivalent circuit is derived by rearranging the switches. The equivalent circuit for this converter consists of CCM (Continuous conduction mode) boost and DCM (Discontinuous conduction mode) buck converter. The analyses for the equivalent CCM boost and DCM buck converter are done using the model of PWM switch. The theoretical modeling results are confirmed through experiment or SIMPLIS simulation.

  • PDF

Analysis of Transient Conduction Heat Loss of Solid Sphere between Constant and Variable Free Convection (상수 또는 변수의 대류 경계조건을 가지는 구의 과도열전도 손실에 대한 해석)

  • Kim, M.J.;Chea, G.H.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.17-22
    • /
    • 2010
  • 본 연구는 구의 과도 열전도에 의한 열손실을 계산하는 데 있어, 외부의 경계조건인 대류의 조건에 해당하는 상황을 상수 및 변수로 가정하였을 경우의 열전달문제를 해석한 것이다. 이 문제를 해결하기 위해 집중열용량법을 사용하고 있으며, 대류열전달계수의 값이 온도의 함수로 변한다고 가정하여 계산하였다. 계산을 수행한 결과 대류경계조건의 값을 상수로 가정한 경우가 열손실이 높이 평가된다는 것을 알았고, 이러한 경향을 상관식으로 정리하였다.

A Comparison between 3-D Analytical and Finite Difference Method for a Trapezoidal Profile Fin

  • Lee, Sung-Joo;Kang, Hyung-Suk
    • Journal of Industrial Technology
    • /
    • v.21 no.A
    • /
    • pp.41-50
    • /
    • 2001
  • A comparison is made of the temperature distribution and heat loss from a trapezoidal profile fin using two different 3-dimensional methods. These two methods are analytical and finite difference methods. In the finite difference method 78 nodes are used for a fourth of the fin. A trapezoidal profile fin being the height of the fin tip is half of that of the fin base is chosen arbitrarily as the model. One of the results shows that the relative error in the total convection heat loss obtained by using 78 nodes in the finite difference method as compared to the heat conduction through the fin root obtained by analytic method seems to be good (i.e., -3.5%

  • PDF

PRACTICAL SWITCH BASED STATE-SPACE MODELING OF DC-DC CONVERTERS ( PART II ) : ALL PARASITICS (실제적인 스윗치를 사용한 직류 변환기의 상태 공간 모델링 (II) : 모든 부수적인 요소 포함)

  • Rim, C.T.;Joung, G.B.;Cho, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.109-112
    • /
    • 1988
  • All parasitics such as switch conduction voltages, conduction resistances, switching times and ESR''s of capacitors are counted in the new state-space modeling based on non-ideal switching functions. An equivalent simplified model is derived from the complex circuit with parasitics. Hence the results are very simple and exact, which are very important features of modelings. The pole frequency, dc voltage gain, and efficiency of the general converter, the buck-boost converter are analyzed and verified by the experiments with good agreements with the theories. This may be a good summary for the previous works concerned with parasitics.

  • PDF

Electrical Conduction Mechanism of SiC-$ZrB_2$ Composites (SiC-$ZrB_2$계(係) 복합체(複合體)의 전기전도기구(電氣傳導機溝))

  • Ju, Jin-Young;Kwon, Ju-Sung;Shin, Yong-Deok
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1336-1338
    • /
    • 1997
  • Relations between the composites of SiC-$ZrB_2$ electro-conductive ceramic composites and their electrical resistivity, as well as their temperature, were investigated. The electrical resistivity of hot-pressed composites was measured by the Pauw method in the temperature of RT to $100^{\circ}C$. The electrical resistivity of the composites follow the electrical conduction model for a homogenous mixture of two kinds of particles with different conductivity. Also the electrical resistivity versus temperature curves indicate the formation of local chains of $ZrB_2$ particles. In the case of SiC-$ZrB_2$ composites containing above 30Vol.% $ZrB_2$ showed PTCR, whereas the electrical resistivity of SiC-15Vol.% $ZrB_2$ showed NTCR.

  • PDF

Cooling Characteristics of a Parallel Channel with Protruding Heat Sources Using Convection and Conduction Heat Transfer (돌출된 열원이 있는 채널에서 대류와 전도열전달을 이용한 냉각특성)

  • 손영석;신지영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.923-930
    • /
    • 2002
  • Cooling characteristics of a parallel channel with protruding heat sources using convection and conduction heat transfer are studied numerically. A two-dimensional model has been developed for numerical prediction of transient, compressible, viscous, laminar flow, and conjugate heat transfer between parallel plates with uniform block heat sources. The finite volume method is used to solve the problem. The assembly consists of two channels formed by two covers and one printed circuit board which has three uniform heat source blocks. Six different cooling methods are considered to find out the most efficient cooling method in a given geometry and heat sources. The velocity and temperature fields of cooling medium, the temperature distribution along the block surface, and the maximum temperature in each block are obtained. The results are compared to examine the cooling characteristics of the different cooling methods.

The oscillation conduction characteristics of ZnO varistor fabricated with 3-composition seed grain method (3-성분 종입자법으로 제조한 저전압 ZnO 바리스터의 발진 전도특성)

  • 장경욱;김영천;황석영;김용주;이준웅
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1019-1026
    • /
    • 1996
  • In this study, we may be presented the carrier oscillation properties for the low-voltage varistor fabricated by a new method of three composition seed grain, in order to analyze the behavior of carriers at the its equivalent circuit model. The oscillation phenomena of carriers appeared from current-voltage characteristics under knee voltage is shown by the transient flow of nontrapped carriers group in the trap level of intergranular layer, surface state and/or depletion layer. In particularly, current oscillation phenomena is hardly shown in the high electric field. It is that the injected carriers from both electrodes are directly from the conduction band of forward biased ZnO grain through the intergranular layer into the reverse biased ZnO grain, because the trap level in the electric field above the knee voltage is mostly filled.

  • PDF