• 제목/요약/키워드: conditioning treatment

검색결과 239건 처리시간 0.032초

Chevron 유로 내의 미시적 해석 결과를 통한 대형 판형열교환기 특성에 대한 준미시적 해석 (A Semimicroscopic Analysis for the Characteristics of a Large Plate Heat Exchanger through a Microscopic Flow and Heat Transfer Analyses inside a Chevron Passages)

  • 이나리;이명성;이상혁;허남건
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1159-1165
    • /
    • 2009
  • In the present study, the flow and heat transfer characteristics of a large plate heat exchanger are investigated numerically. The flow passages are very complicated due to the grooved corrugation patterns of the plate surface so that the detailed mesh and the large amount of the computation time have to be required in the numerical simulation for the conjugate heat transfer analysis. In order to accomplish the efficient and fast analysis of the heat transfer characteristics in the plate heat exchanger, a semimicroscopic method using the porous media model has been investigated numerically. The results showed that the characteristics of the heat transfer and pressure drop, which are respectively presented with Colburn j-factor and Fanning f-factor, are in a good agreement between the detailed mesh and the porous media model. The results of the present study could be applicable to the numerical analysis of entire flow passages in the large plate heat exchanger using porous media treatment.

  • PDF

기관지천식에서의 신경적 기전 (Neural Mechanism in Bronchial Asthma)

  • 최병휘
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권2호
    • /
    • pp.73-86
    • /
    • 1994
  • In addition to classic cholinergic and adrenergic pathways, the existence of a third division of autonomic control in the human airways has been proved. It is called a nonadrenergic noncholinergic(NANC) nervous system, and difficult to study in the absence of specific blockers. Neuropeptides are certainly suggested to be transmitters of this NANC nervous system. It is very frustrating to understand the pathophysiologic role of these peptides in the absence of any specific antagonists. However, further studies of neuropeptides might eventually lead to novel forms of treatment for bronchial asthma. Another study of the interaction between different components of the autonomic nervous system, either in ganglionic neurotransmission or by presynaptic modulation of neurotransmitters at the end-organ will elute neural control in airway disease, particularly in asthma. Studies of how autonomic control may be disordered in airway disease should lead to improvements in clinical management. Epithelial damage due to airway inflammation in asthma may induce bronchial hyperresponsiveness. Axon reflex mechanism is one of possible mechanisms in bronchial hyperresponsiveness. Epithelial damage may expose sensory nerve terminals and C-fiber nrve endings are stimulated by inflammatory mediators. Bi-directional communication between the nerves and mast cells may have important roles in allergic process. The psychological factors and conditioning of allergic reactions is suggested that mast cell activation might be partly regulated by the central nervous system via the peripheral nerves. Studies in animal models, in huamn airways in vitro and in patients with airway disease will uncover the interaction between allergic disease processes and psychologic factors or neural mechainsms.

  • PDF

비강 내 공기유동과 열 및 물질전달에 관한 연구 (Research on the nasal airflow and heat and mass transfer)

  • 김성균;휜광림;박준형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1479-1483
    • /
    • 2008
  • The three main physiological functions of nose are air-conditioning, filtering and smelling. Knowledge of airflow characteristics in nasal cavities is essential to understand the physiological and pathological aspects of nasal breathing. Several studies have utilized physical models of the healthy nasal cavity to investigate the relationship between nasal anatomy and airflow. In our laboratory, there have been a series of experimental investigations on the nasal airflow in normal and deformed nasal cavity models by PIV under both constant and periodic flow conditions. In this time, airflow inside normal nasal cavity is investigated numerically by the FVM general purpose code. The comparisons with PIV measurement are appreciated. Heat and humidity transfer is dealt numerically. Dense CT data and careful treatment of model surface under the ENT doctor’s advice provide more sophisticated cavity models for both PIV experiment and numerical grid system. Average and RMS velocity distributions have been obtained for inspirational and expirational nasal. Temperature distribution, heat and humidity transfer through the mucosa are obtained.

  • PDF

연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구 (A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process)

  • 이주상;김신도;김광영;김종호
    • 한국대기환경학회지
    • /
    • 제11권2호
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF

사용후핵연료 처리를 위한 ACP 핫셀의 정상운영 및 사고시 방사선 환경영향평가 (Radiation Dose Assessment of ACP Hotcell for Spent Fuel Treatment in Normal Operation & Accident Case)

  • 국동학;정원명;구정회;조일제;이은표;유길성
    • 방사성폐기물학회지
    • /
    • 제2권3호
    • /
    • pp.155-164
    • /
    • 2004
  • 사용후핵연료의 효율적인 관리를 위하여 원자력연구소에서 개발중인 사용후핵연료 차세대관리 종합공정(ACP)은 공정타당성연구 단계를 마치고 이의 실증을 위한 $\alpha$-${\gamma}$ type핫셀 건설 단계에 이르렀다. 핫셀의 설계에 앞서 사용후핵 연료를 취급하게 되는 과정에서 발생할 수 있는 방사능에 대한 환경영향평가를 정상운전 시와 사고발생 시로 나누어 수행하였다. 평가에 필요한 자료들은 공정의 개념설계 보고서와 최근 연구소부지 기상 테이터 및 부지특성 자료를 바탕으로 하였으며 기존의 유사한 시설에 대한 평가방법을 참조하였다. 각 핵종별 발생량과 방출량을 계산하여 피폭선량을 계산하였으며 평가결과 원자력법관련 규제기준과 핫셀이 위치하게 되는 IMEF 건물의 안전성분석 기준보다 매우 안전한 결과를 얻어 시설 운영에 대한 안전성을 확보하였다.

  • PDF

하비갑개 수술 후 비강 모델 내의 세부 유동장의 실험 및 전산 유동가시화 (Experimental and Numerical Flow Visualization on Detailed Flow Field in the Post-surgery Models for the Simulation of the Inferior Turbinectomy)

  • 장지원;허고은;김성균
    • 한국가시화정보학회지
    • /
    • 제9권3호
    • /
    • pp.65-70
    • /
    • 2011
  • Three major physiological functions of nose can be described as air-conditioning, filtering and smelling. Detailed knowledge of airflow characteristics in nasal cavities is essential to understanding of the physiological and pathological aspects of nasal breathing. In our laboratory, a series of experimental investigations have been conducted on the airflows in normal and abnormal nasal cavity models by means of PIV under both constant and periodic flow conditions. In this work, more specifically experimental and numerical results on the surgically modified inferior turbinate model were presented. With the high resolution CT data and a careful treatment of the model surface under the ENT doctor's advice yielded quite sophisticated cavity models for the PIV experiment. Physiological nature of the airflow was discussed in terms of velocity distribution and vortical structure for constant inspirational flow. Since the inferior and middle turbinate are key determinants of nasal airflow, the turbinectomy obviously altered the main stream direction. This phenomenon may cause local changes in physiological function and the flow resistance.

치석제거 및 치근활택술 시에 테트라싸이클린 젤의 국소적 도포 (TOPICAL APPLICATION OF TETRACYCLINE GEL IN SCALING AND ROOT PLANING)

  • 한수부;이재일;허정미;장미경;심창구;이철우
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.647-658
    • /
    • 1993
  • The purpose of this study is to examine the influence of 5% tetracycline(Tc) gel on healing of gingival tissue and change of diseased root surface when used with nonsurgical procedure. 7 patients with advanced periodontitis were received thorough scaling and root planning, followed by saline irrigation on 10 randomly selected control teeth and Tc gel application for 5 minutes with specifically designed plastic instrument of 10 test teeth in contralateral side. At 0, 1, 7, 14, and 21 days after treatment, biopsy and extraction were carried out. At day 7, Tc group showed decreased inflammation and delayed proliferation of pocket epithelium in comparison with control group which was continued for all experimental days. Scanning electron microscopic finding revealed demineralized and cleaned root surface with exposed dentinal tubules in Tc gel group. In the present study, clinically successful result is expected with combined use of nonsurgical periodontal therapy and intrapocket application of Tc gel.

  • PDF

Acupuncture in Sport Recovery: A Brief Review

  • CHAPLEAU, Christopher
    • 식품보건융합연구
    • /
    • 제6권2호
    • /
    • pp.23-26
    • /
    • 2020
  • Active and therapeutic sport recovery is becoming a popular and important component in approving performance for pro and recreational athletes alike. It is also helping in the realm of injury prevention. In the search of finding modalities that are widely effective, natural, and safe, acupuncture is a viable and cost-effective treatment for helping athletes achieve this goal. More direct related research is needed, but testimonials from pro athletes and the body of research that currently exists provides powerful evidence on acupunctures ability to help with enhancing recovery. Specializing in acupuncture and exercise science, Chris integrates acupuncture into musculoskeletal rehabilitation therapy or fitness training for pain modulation, speedy recovery, and enhanced performance. Clients can choose to focus on one-on-one corrective exercise therapy, manual and massage therapy, or acupuncture. However, for best results, Chris recommends all three. Other modalities that he uses in therapy are acu-taping, herbal therapy, nutrition supplementation, cupping, guasha, and stretching techniques. The corrective exercise component is one-on-one body balancing management, focusing on strength and conditioning, post physical rehab - exercise therapy, integrative sport specific exercise, weight loss, core strengthening, dynamic lumbar stabilization, active recovery techniques, and myo-fascial release techniques. The acupuncture component focuses on sport injuries, myofascial pain, peripheral neuropathy, arthritis, facial rejuvenation, stress, smoking cessation, addiction detoxification program, weight management, sport recovery and performance.

수평형 재생증발식 냉방기의 성능시험 (Performance Test for a Horizontal Regenerative Evaporative Cooler)

  • 송귀은;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

도류벽 형태에 따른 정수지 내 유동 특성과 소독능 변화에 대한 수치 해석적 연구 (Numerical Analysis for Characteristic of Flow and Disinfection Performance with Variation of Guide Wall in Clearwell)

  • 이석원;박준정;리광훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.767-772
    • /
    • 2006
  • The SWTR(Surface Water Treatment Rule) requires achieving removal 99.9% Giardia and 99.99% Virus. To remove Giardia and Virus, disinfection process is essential process. CT is important index for Disinfection performance. CT value is expressed by CXT. C is represented by disinfection concentration and T is represented by $T_{10}$ which means 90% contact time in clearwell. To improve Disinfection performance, it is desirable to increase $T_{10}$. Primary factor affected $T_{10}$ is flow Pattern. Because guide wall change that flow pattern is uniform, we have installed guide wall to increase $T_{10}$. In this paper, we have performed numerical analysis for clearwell installed symmetric guide wall and center divided guide wall using CFD. We have analyzed flow pattern and $T_{10}$ in each clearwell. And. we compare symmetric guide wall with center divided guide wall in flow pattern and $T_{10}$.

  • PDF