• 제목/요약/키워드: concrete-encased structure

검색결과 18건 처리시간 0.019초

Experimental study on seismic behavior of frame structures composed of concrete encased columns with L-shaped steel section and steel beams

  • Zeng, Lei;Ren, Wenting;Zou, Zhengtao;Chen, Yiguang;Xie, Wei;Li, Xianjie
    • Earthquakes and Structures
    • /
    • 제16권1호
    • /
    • pp.97-107
    • /
    • 2019
  • The frame structures investigated in this paper is composed of Concrete encased columns with L-shaped steel section and steel beams. The seismic behavior of this structural system is studied through experimental and numerical studies. A 2-bay, 3-story and 1/3 scaled frame specimen is tested under constant axial loading and cyclic lateral loading applied on the column top. The load-displacement hysteretic loops, ductility, energy dissipation, stiffness and strength degradation are investigated. A typical failure mode is observed in the test, and the experimental results show that this type of framed structure exhibit a high strength with good ductility and energy dissipation capacity. Furthermore, finite element analysis software Perform-3D was conducted to simulate the behavior of the frame. The calculating results agreed with the test ones well. Further analysis is conducted to investigate the effects of parameters including concrete strength, column axial compressive force and steel ratio on the seismic performance indexes, such as the elastic stiffness, the maximum strength, the ductility coefficient, the strength and stiffness degradation, and the equivalent viscous damping ratio. It can be concluded that with the axial compression ratio increasing, the load carrying capacity and ductility decreased. The load carrying capacity and ductility increased when increasing the steel ratio. Increasing the concrete grade can improve the ultimate bearing capacity of the structure, but the ductility of structure decreases slightly.

매립형 철골합성구조의 부등건조수축에 따른 내부강재구속효과에 관한 연구 (Embeded-Steel Restraining Effects due to Differential Drying Shrinkage in SRC(Steel Reinforced Concrete ) Structures)

  • 조병환;김성호;김영진;고상윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.303-308
    • /
    • 2000
  • During the past few decades, several composite steel-concrete structural systems have been used and the demand of SRC (Steel Reinforced Concrete) structure increases on the construction of coping structures. But drying shrinking of concrete which is not uniform and the additional restraining effects of encased steel in concrete may cause the crack which leads to harmful damage to structure. In this study, specimens were made to show the restraining effects of embeded-steel in concrete and the differential drying shrinkage strains at various position of concrete were measured and analysed by Compensation Line Method. The results showed that there were remarkable difference in the drying shrinkage according to 속 depth of the concrete, and the tensile stress of the concrete near to encased steel showed the significant amount of stress contrary to 속 specimen which has no embeded-steel.

  • PDF

Experimental and analytical performance evaluation of steel beam to concrete-encased composite column with unsymmetrical steel section joints

  • Xiao, Yunfeng;Zeng, Lei;Cui, Zhenkun;Jin, Siqian;Chen, Yiguang
    • Steel and Composite Structures
    • /
    • 제23권1호
    • /
    • pp.17-29
    • /
    • 2017
  • The seismic performance of steel beam to concrete-encased composite column with unsymmetrical steel section joints is investigated and reported within this paper. Experimental and analytical evaluation were conducted on a total of 8 specimens with T-shaped and L-shaped steel section under lateral cyclic loading and axial compression. The test parameters included concrete strength, stirrup ratio and axial compression ratio. The response of the specimens was presented in terms of their hysterisis loop behavior, stress distribution, joint shear strength, and performance degradation. The experiment indicated good structural behavior and good seismic performance. In addition, a three-dimensional nonlinear finite-element analysis simulating was conducted to simulate their seismic behaviors. The finite-element analysis incorporated both bond-slip relationship and crack interface interaction between steel and concrete. The results were also compared with the test data, and the analytical prediction of joint shear strength was satisfactory for both joints with T-shaped and L-shaped steel section columns. The steel beam to concrete-encased composite column with unsymmetrical steel section joints can develop stable hysteretic response and large energy absorption capacity by providing enough stirrups and decreased spacing of transverse ties in column.

Effect of position of hexagonal opening in concrete encased steel castellated beams under flexural loading

  • Velrajkumar, G.;Muthuraj, M.P.
    • Computers and Concrete
    • /
    • 제26권1호
    • /
    • pp.95-106
    • /
    • 2020
  • Castellated beams fabricated from standard I-sections are being used for several structural applications such as commercial and industrial buildings, multistory buildings, warehouses and portal frames in view of numerous advantages. The advantages include enhanced moment of inertia, stiffness, flexural resistance, reduction in weight of structure, by passing the used plate girders, the passage of service through the web openings etc. In the present study, experimental and numerical investigations were carried out on concrete encased steel castellated beams with hexagonal openings under flexural loading. Various positions of openings such as along the neutral axis, above the neutral axis and below the neutral axis were considered for the study. From the experimental findings, it has been observed that the load-carrying capacity of the castellated beam with web opening above neutral axis is found to be higher compared to other configurations. Nonlinear finite element analysis was performed by using general purpose finite element software ABAQUS considering the material nonlinearities. Concrete damage plasticity model was employed to model the nonlinearity of concrete and elasto-plastic model for steel. It has been observed that FE model could able to capture the behaviour of concrete encased steel castellated beams and the predicted values are in good agreement with the corresponding experimental values.

Stress-transfer in concrete encased and filled tube square columns employed in top-down construction

  • Kim, Sun-Hee;Yom, Kyong-Soo;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.63-77
    • /
    • 2016
  • Top-down construction is a construction technique in which pit excavation and structure construction are conducted simultaneously. Reducing construction time and minimizing noise and vibration which affect neighboring structures, the technique is widely employed in constructing downtown structures. While H-steel columns have been commonly used as core columns, concrete filled steel tube (CFT) columns are at the center of attention because the latter have less axial directionality and greater cross-sectional efficiency than the former. When compared with circular CFT columns, square CFT columns are more easily connected to the floor structure and the area of percussion rotary drilling (PRD) is smaller. For this reason, square CFT columns are used as core columns of concrete encased and filled square (CET) columns in underground floors. However, studies on the structural behavior and concrete stress transfer of CET columns have not been conducted. Since concrete is cast according to construction sequence, checking the stress of concrete inside the core columns and the stress of covering concrete is essential. This paper presents the results of structural tests and analyses conducted to evaluate the usability and safety of CET columns in top-down construction where CFT columns are used as core columns. Parameters in the tests are loading condition, concrete strength and covering depth. The compressive load capacity and failure behavior of specimens are evaluated. In addition, 2 cases of field application of CET columns in underground floors are analyzed.

Experimental study on energy dissipation and damage of fabricated partially encased composite beams

  • Wu, Kai;Liu, Xiaoyi;Lin, Shiqi;Tan, Chengwei;Lu, Huiyu
    • Computers and Concrete
    • /
    • 제30권5호
    • /
    • pp.311-321
    • /
    • 2022
  • The interfacial bond strength of partially encased composite (PEC) structure tends to 0, therefore, the cast-in-place concrete theoretically cannot embody better composite effect than the fabricated structure. A total of 12 specimens were designed and experimented to investigate the energy dissipation and damage of fabricated PEC beam through unidirectional cyclic loading test. Because the concrete on both sides of the web was relatively independent, some specimens showed obvious asymmetric concrete damage, which led to specimens bearing torsion effect at the later stage of loading. Based on the concept of the ideal elastoplastic model of uniaxial tensile steel and the principle of equivalent energy dissipation, the energy dissipation ductility coefficient is proposed, which can simultaneously reflect the deformability and bearing capacity. In view of the whole deformation of the beam, the calculation formula of energy dissipation is put forward, and the energy dissipation and its proportion of shear-bending region and pure bending region are calculated respectively. The energy dissipation efficiency of the pure bending region is significantly higher than that of the shear-bending region. The setting of the screw arbors is conducive to improving the energy dissipation capacity of the specimens. Under the condition of setting the screw arbors and meeting the reasonable shear span ratio, reducing the concrete pouring thickness can lighten the deadweight of the component and improve the comprehensive benefit, and will not have an adverse impact on the energy dissipation capacity of the beam. A damage model is proposed to quantify the damage changes of PEC beams under cyclic load, which can accurately reflect the load damage and deformation damage.

Evolution of concrete encased - CFST column: A comprehensive review on structural behavior and performance characteristics

  • Namitha Raveendran;Vasugi K
    • Steel and Composite Structures
    • /
    • 제51권6호
    • /
    • pp.619-645
    • /
    • 2024
  • In the construction industry, composite structures have revolutionized traditional design principles, opening innovative possibilities. The Concrete Encased - Concrete Filled Steel Tubular (CE-CFST) column stands out as a distinctive composite structure, offering structural stability and resilience for various engineering applications. Comprising Reinforced Concrete (RC) and Concrete Filled Steel Tubular (CFST) components, CE-CFST columns are valued for their inherent properties, including ductility and rigidity, CE-CFST is commonly used in the construction of bridges, high-rise buildings, and more. This article aims to provide a concise overview of the evolutionary development of CE-CFST columns and their performance in structural applications. Through a comprehensive review, the study delves into the behaviour of CE-CFST columns under different scenarios. It examines the influences of key parameters such as size, infills, cross section, failure causes, and design codes on the performance of CE-CFST columns, highlighting their enhanced functionality and future potential. Moreover, the review meticulously examines previous applications of CE-CFST columns, offering insights into their practical implementation.

콘크리트 충전 브릿지 플레이트(대골형 파형강판) 부재의 성능평가 (Performance Evaluation of Encased-Concrete Bridge Plate(Deep Corrugated Steel Plate) Member)

  • 심종성;박철우;김태수;이형호;강태성
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.297-303
    • /
    • 2010
  • 현재 개발된 콘크리트 충전 대골형 파형 강판은 아치형 플레이트의 구조로서 그 특징은 구조물이 아치의 형상을 가지므로 모멘트가 작게 발생하는 압축력 지배구조의 구조적 특성을 가지게 되며 이에 따라 강재를 덧대 준공된 공간을 압축력에 유리한 콘크리트를 충전 강재 콘크리트 합성단면을 형성하여 압축력에 대한 강도 발현증대를 목적으로 한다. 이 연구에서는 새로운 개념의 콘크리트 충전 대골형 파형강판(브릿지 플레이트) 부재의 압축 및 휨 시험을 실시하여 평가된 압축력과 콘크리트 충전 브릿지 플레이트 구조물의 설계방법인 캐나다 도로교설계기준(CHBDC)의 방법으로 설계압축력을 산정하여 비교 검토함으로서 새로운 개념의 콘크리트 충전 브릿지 플레이트 부재의 안전율을 평가하였다. 설계압축력과 성능평가 시험을 통하여 얻어진 축력을 비교하여 안전율을 검토한 결과 적정 안전율 2.0이상 과도하게 나타나 CHCBD을 이용한 설계가 매우 보수적으로 평가되고 있으며, 이 연구 결과를 바탕으로 안전율을 설계에 반영한다면, 단면축소 및 시공비용 절감에 따른 경제적인 시공이 가능할 것으로 판단된다.

시공단계를 고려한 피복충전형 콘크리트충전 각형기둥의 구조적 거동 분석 (Structural Behavior Analysis of Concrete Encased and Filled tube Square Column with Construction Sequence)

  • 김선희;염경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제27권1호
    • /
    • pp.43-52
    • /
    • 2015
  • 구조물의 기둥은 층에 따라 받는 내력이 상이함에도 시공의 오차를 줄이고 구조설계의 편의를 위해 상부층부터 하부층의 기둥단면은 동일하게 설계되고 있다. 그럼에도 불가피하게 상하부의 기둥의 단면이 상이하는 경우가 발생된다. 예를들어 초고층 구조물 또는 증축 및 보수에 의해 기둥을 보강할 경우이다. 이렇듯. 선 기둥과 후 피복이 되는 기둥을 피복충전형 콘크리트 충전기둥이라 할 때, 가력조건이 다르므로 재하상태를 나뉘어 구조적 안정성을 확인할 필요가 있다. 그럼에도 국내외적으로 가력조건에 따른 합성기둥에 대한 내력과 변형연구는 전무한 상태에 있다. 따라서 본 연구에서는 구조실험을 통해 가력조건 및 콘크리트 강도, 피복두께 변화에 의한 피복충전형 콘크리트 각형 기둥의 내력과 거동을 분석하였다.

800MPa 강재 및 100MPa 콘크리트를 적용한 ㄱ형 강재 매입형 합성기둥의 편심압축실험 (Eccentric Axial Loading Test for Concrete-Encased L-section Columns using 800MPa Steel and 100MPa Concrete)

  • 김창수;박홍근;이호준;최인락
    • 한국강구조학회 논문집
    • /
    • 제25권2호
    • /
    • pp.209-222
    • /
    • 2013
  • 800MPa급 강재와 100MPa급 콘크리트를 적용한 매입형 합성기둥에 대하여 편심압축실험을 수행하였다. 강재단면의 모멘트팔길이와 변형(응력)을 증가시켜 고강도강재의 성능활용을 극대화할 수 있도록, ㄱ형 강재단면을 네 모서리에 집중 배치한 후, 래티스철근, 링크철근, 띠판을 이용하여 일체화하였다. 이 경우 강재단면의 강력한 횡구속효과로 인해 심부콘크리트의 성능도 개선된다. 실험결과 ㄱ형 강재 매입형 기둥은 H형 강재 매입형 기둥에 비하여 최대강도와 유효휨강성이 1.4배 이상 증가하였다.