Embeded-Steel Restraining Effects due to Differential Drying Shrinkage in SRC(Steel Reinforced Concrete ) Structures

매립형 철골합성구조의 부등건조수축에 따른 내부강재구속효과에 관한 연구

  • 조병환 (정회원, 한양대학교 도시환경건설공학부) ;
  • 김성호 (현대건설 기술연구소 구조연구실) ;
  • 김영진 (정회원, 한양대학교 토목공학과) ;
  • 고상윤 (정회원, 한양대학교 토목공학과)
  • Published : 2000.04.01

Abstract

During the past few decades, several composite steel-concrete structural systems have been used and the demand of SRC (Steel Reinforced Concrete) structure increases on the construction of coping structures. But drying shrinking of concrete which is not uniform and the additional restraining effects of encased steel in concrete may cause the crack which leads to harmful damage to structure. In this study, specimens were made to show the restraining effects of embeded-steel in concrete and the differential drying shrinkage strains at various position of concrete were measured and analysed by Compensation Line Method. The results showed that there were remarkable difference in the drying shrinkage according to 속 depth of the concrete, and the tensile stress of the concrete near to encased steel showed the significant amount of stress contrary to 속 specimen which has no embeded-steel.

Keywords