• 제목/요약/키워드: concrete materials

검색결과 4,018건 처리시간 0.033초

복합소재의 건설분야 응용현황과 콘크리트 합성압축부재의 개발 (Application of Composites to Construction Industry and Development of Concrete Filled Composite Compression Member)

  • 이성우;박신전
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.183-188
    • /
    • 1999
  • Due to many advantages of advanced composite materials, research on the application of composites to the construction industry is initiated. In this paper, fabrication methods efficient for infrastructures and application examples of each method are discussed. It also presents the structural characteristics of concrete filled glass fiber reinforced composite tubular member. Experimental results shows that strength and ductility of composite compression member is considerably increased due to concrete confinement action of composite surface.

  • PDF

채움재 종류에 따른 투수콘크리트 성능 연구 (Study on Porous Concrete According to Filler)

  • 노병철;최규형;김정훈;차광일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.741-744
    • /
    • 2006
  • The study focuses on the mixture of materials for the development of porous concrete with unsaturated polyester resin. The materials used in the mixture include the coarse aggregates unsaturated polyester resin as binder, calcium carbonate and sand as a filler. An experimental procedure has been carried out to select the best combination of the materials that satisfy both the required permeability and compressive strength.

  • PDF

Galvanic Sensor System for Detecting the Corrosion Damage of the Steel in Concrete

  • Kim, Jung-Gu;Park, Zin-Taek;Yoo, Ji-Hong;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • 제3권3호
    • /
    • pp.118-126
    • /
    • 2004
  • The correlation between sensor output and corrosion rate of reinforcing steel was evaluated by laboratory electrochemical tests in saturated $Ca(OH)_2$ with 3.5 wt.% NaCl and confirmed in concrete environment. In this paper, two types of electrochemical probes were developed: galvanic cells containing of steel/copper and steel/stainless steel couples. Potentiodynamic test, weight loss measurement, monitoring of open-circuit potential, linear polarization resistance (LPR) measurement and electrochemical impedance spectroscopy (EIS) were used to evaluate the corrosion behavior of steel bar embedded in concrete. Also, galvanic current measurements were conducted to obtain the charge of sensor embedded in concrete. In this study, steel/copper and steel/stainless steel sensors showed a good correlation in simulated concrete solution between sensor output and corrosion rate of steel bar. However, there was no linear relationship between steel/stainless steel sensor output and corrosion rate of steel bar in concrete environment due to the low galvanic current output. Thus, steel/copper sensor is a reliable corrosion monitoring sensor system which can detect corrosion rate of reinforcing steel in concrete structures.

마이크로 캡슐을 이용한 항균 기능성 모르타르 및 콘크리트의 개발 (Development of Anti-Bacteria Mortar and Concrete using Microcapsule)

  • 박석균;이병재;김기수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.519-522
    • /
    • 2003
  • In this study, we encapsulate the core materials which have long term resisting properties to the bacteria. We also try to apply those capsules to the mortar and concrete which is using for the structures and ornament materials. Various wall thickness, shape, and membrane structure of microcapsule are tested and construction properties of the mortar and concrete which contain microcapsules are examined. Finally the microcapsules with anti-bacteria which can be used for mortar and concrete are developed.

  • PDF

하이브리드 보강기법을 활용한 고강도 콘크리트 구조 부재의 성능 향상 (Enhancing the Performance of High-Strength Concrete Members Using Hybrid Reinforcing Technique)

  • 양준모
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.479-480
    • /
    • 2010
  • 콘크리트 구조물의 고성능, 고내구성화를 위해 콘크리트 뿐만 아니라 보강 재료에 대한 성능 향상이 요구되고 있다. 본 연구에서는 고성능의 보강재료를 복합적으로 적용하여 고강도 콘크리트 구조물의 성능 극대화를 도모하는 하이브리드 보강기법에 대한 연구를 수행하였다.

  • PDF

보조기층재로서 폐콘크리트의 안정성에 관한 연구 (A Study on the Stability of the Waste Concrete as the Subgrade Materials)

  • 김태봉;박원철;서상구;안상로
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.160-167
    • /
    • 1996
  • The construction waste concrete produce from the demolished concrete structures. These waste concrete materials are useful and valuable for fill and subgrade and are considered to use as the subgrade material of the road. To use the subgrade of the road with the waste concrete, the several experiments involved with compaction test and laboratory C. B. R. etc. are performed. These experiments are compared with criteria of the road construction manual. It is shown that the quality of the construction waste concrete satisfies that of the subgrade mentioned in the road construction manual.

  • PDF

Adhesion Strength and Other Mechanical Properties of SBR Modified Concrete

  • Chmielewska, Bogumila
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권1호
    • /
    • pp.3-8
    • /
    • 2008
  • Polymer-cement composites are known repair materials. The aim of this work is to investigate the influence of various amount of dispersion of carboxylated styrene-butadience copolymer on the selected mechanical properties of polymer-cement concrete (PCC) and on its adhesion to ordinary concrete. The compressive, flexural and tensile strengths as well as frost resistance and fracture resistance of the composites are tested. Adhesion strength of PCC to ordinary concrete, as one of most important performance of good repair material is evaluated and analyzed using three test methods. The results obtained in standard pull-off test are compared with the two other tests. The first one, which is an adaptation of WST (wedge splitting test) characterizes crack propagation in the plane of bond created during repair. In the second test the resistance to shear is a measure of adhesion strength.

포졸란 함유 콘크리트의 공극구조와 투과특성 (Pore Structure and Permeability of Concrete Containing Pozzolanic Materials)

  • 김재신;소형석;소승영;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.159-162
    • /
    • 1999
  • The paper presents results of an investigation on the permeability characteristics and pore structure of concrete containing different levels of fly ash, silica fume, or blast furnace slag. The total cementitious content was 351kg/㎥, and the water/cementitious materials ratio was 0.55. The porosity and pore structure of representative pastes of the matrix were measured using mercury intrusion porosimetry, and the permeability characteristics of concrete were also determined by water and oxygen permeability, chloride ion penetration. The results show that significant reduction in permeability of concrete containing pozzolanic materials due to formation of a discontinuous macro-pore system which inhibits flow. And, the permeability of concrete and pore structure(capillary porosity or total porosity) shows linear relationship.

  • PDF

경화된 콘크리트에 접착된 폴리머 콘크리트의 부착강도 특성 (Bonding Strength of bonded Polymer Concrete on Cured Cement Concrete)

  • 홍승호;권순민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.353-358
    • /
    • 2001
  • The cement concrete pavements are designed twenty years of performance life in Korea. At the present time, some expressways have been elapsed seventy percent of performance life which are detecting local failures. The most repair methods using to repair failures are partial depth repair and full section repair. These methods are most important bonding strength between rapid curing materials and substrate concrete pavements. This study was performed to evaluate bonding strength of the composites section made of rapid curing material and substrate concrete pavements. The pull-out tester was used to test bonding strength for the composites section made of each materials. In the results of the test, the bonding strength values of the epoxy mortar and acrylic mortar are higher than those of the other materials. The performance life of repaired section is affected by various factor. The bonding strength of bonded composites section may be affect the performance life, significantly.

  • PDF

Fracture process of rubberized concrete by fictitious crack model and AE monitoring

  • Wang, Chao;Zhang, Yamei;Zhao, Zhe
    • Computers and Concrete
    • /
    • 제9권1호
    • /
    • pp.51-61
    • /
    • 2012
  • According to the results of three-point bending tests of rubberized concrete and plain concrete, the parameters such as total fracture energy ($G_F$), initial fracture energy ($G_f$), and tensile strength ($f_t$) are obtained for concrete material. Using ABAQUS software and a bilinear softening fictitious crack model, the crack propagation process was simulated and compared to the experimental results. It is found that the increase of AE hit count has a similar trend with the increase of energy dissipation in FEM simulation. For two types of concretes, both experimental results and numerical simulation indicate that the rubberized concrete has a better fracture resistance.