• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.111 seconds

The Analysis of Musle Fatigue for Urban Bus Driver using Electromyography (근전도를 이용한 시내버스 운전자 피로도 분석)

  • Kim, Kyong;Kim, Jae-Jun;Lee, Chan-Ki;Kim, Dong-Won;Kwon, Tae-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.584-590
    • /
    • 2009
  • Since driving include compilcated actions that require a variety of abillity and cause extrme concentration or strain, divers tend to feel tired easiy. However, divers can't recognize fatigue degree by himself and accordingly the methods to measure quantitative fatigue degree exactly is quite difficult to be secured. In this study, the most efficient driving posture was suggested based on the analysis of quantitative muscular strength and fatigue degree according to posture. The driver whom we experimented included 9 commercial bus drivers. We also analyzed quantitative legs' muscular strength according te operating each pedal, left and right then we analyzed muscular strength and muscular fatigue degree according to driving pattern while driving commercial buses. And then we suggested the most efficient driving posture.

  • PDF

A study on the concentration distribution of CO and $CO_2$ by a form of parking lot in the multiplex use facility (다중이용시설의 주차장 형태에 따른 CO, $CO_2$ 의 농도분포에 관한 연구)

  • Sin, Ji-Won;Kim, Tea-Woo;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.316-321
    • /
    • 2006
  • Multiplex use facility emphasized the importance of indoor air environment because many people using that place. People using parking lot of multiplex use facility in little time, but a pollutant of in indoor air menacing user health. This study measure and analyze the CO, $CO_2$ for better air quality of an indoor parking lot in the multiplex user facility. As a result, two-way opened above ground parking lot is higher numerical value of CO, $CO_2$ than an underground parking lot. And a parking lot of square form is higher numerical value of $CO_2$ than a parking lot of rectangle form.

  • PDF

Consideration on the Risk of Corrosion Assessment in Reinforced Concrete Structure by Corrosion Potential Criterion (부식전위 기준에 의한 철근콘크리트 구조물의 부식진단의 위험성에 관한 고찰)

  • Jeong, Jin-A
    • Corrosion Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • Corrosion of steel reinforcement is a major factor in the deterioration of harbour and bridge structure. Steel corrosion in concrete must be checked for assessing the condition of a reinforced concrete structure. There are several ways how to measure the corrosion condition of reinforced concrete, but the corrosion potential measurement is a very simple, rapid, cost-effective and non-destructive technique to evaluate the severity of corrosion in reinforced concrete structure, therefore commonly used by engineers. However some particular situations may not relate to the reinforcement corrosion probability and a simple comparison of the corrosion potential data with the ASTM C876 Standard on steel reinforcement corrosion probability could be meaningless and not give reliable informations because of environment factors as oxygen concentration, chloride content, concrete resistance. Therefore this paper explains the risk of corrosion assessment in reinforced concrete structure and how many factors can affect the reliability of the corrosion potential data.

An experimental study on the bypass-type DPF using pneumatic cylinder systems (공압 시스템을 이용한 바이패스형 매연여과장치의 실험적 연구)

  • KIM, Sang-Am
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.73-80
    • /
    • 2018
  • Intermittent duty of emergency generator has problems emitting large quantities of PM and NOx in exhaust gas. The aim of this study is to propose DPF system which can be applied to medium-large emergency generators. The system is composed of soot dust collector, silencer and filter trap, which is designed to reduce PM emissions at the emergency generator start-up. The pneumatic system controls a flow direction of exhaust gas to pass through the soot collector and filter trap until the engine reaches complete combustion condition. An experiment is performed to measure PM content and concentration to analyze the performance and characteristics of the proposed system.

A Study on the Current Detector with Non Contact Type (비접촉식 전류 검출 장치에 관한 연구)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.5
    • /
    • pp.351-356
    • /
    • 2018
  • Commonly, a live-line alarm can be used to measure the electric field strength of a high-voltage system to calculate its current, but it is hard to detect the electric field of shielded cables or concealed structures, such as underground distribution cables. Current sensors can detect the magnetic field in a single core wire, but they cannot determine the magnetic field about a double-core wire because the currents flow in opposite directions. Therefore, it is very difficult to detect certain current problems, such as a fault current in an extension line comprised of a double line. In this paper, to ultimately develop a sensor that can detect the current regardless of line conditions, we used a simulation to determine the concentration of the magnetic field dependent on the distribution of the external magnetic field and the path of each line's core.

Hydroxyl Radical Species Generated by Non-thermal Direct Plasma Jet and Their Qualitative Evaluation

  • Ghimire, B.;Hong, S.I.;Hong, Y.J.;Choi, E.H.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.198.2-198.2
    • /
    • 2016
  • Reactive oxygen and nitrogen species (RONS) can be generated by using non-thermal atmospheric pressure plasma jet which have profound biomedical applications [1, 2]. In this work, reactive oxygen species like hydroxyl radical (OH) are generated by using non-thermal direct plasma jet above water surface using Ar gas and their properties have been studied using ultraviolet absorption spectroscopy. OH radicals are found to be generated simultaneously with the discharge current with concentration of $2.7{\times}1015/cm3$ at 7mm above water surface while their persistence time have been measured to be $2.8{\mu}S$. In addition, it has been shown that plasma initiated ultraviolets play a major role to generate RONS inside water. Further works are going on to measure the temporal behavior of OH and $O2^*-$.

  • PDF

Investigation of Internal Flow Fields of Evaporating of Binary Mixture Droplets (증발하는 이성분혼합물 액적의 유동장 해석)

  • Kim, Hyoungsoo
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2017
  • If a liquid droplet evaporates on a solid substrate, when it completely dries, it leaves a peculiar pattern, which depends on the composition of the liquid. Not only a single component liquid but also complex liquids are studied for a different purpose. In particular, a binary mixture droplet has been widely studied and used for an ink-jet printing technology. In this study, we focus on investigating to visualize the internal flow field of an ethanol-water mixture by varying a concentration ratio between two liquids. We measure the in-plane velocity vector fields and vorticities. We believe that this fundamental study about the internal flow field provides a basic idea to understand the dried pattern of the binary mixture droplet.

A Lagrangian Stochastic Model for Dense Gas Dispersion in the Neutrally-stratified Atmospheric Surface Layer (이상적인 중립 대기경계층에서 고밀도가스의 확산예측을 위한 라그랑지안 확률모델)

  • Kim, Byung-Gu;Lee, Changhoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.537-545
    • /
    • 2005
  • A new dispersion model for dense gas is constructed in the Lagrangian framework. Prediction of concentration by the proposed model is compared with measure data obtained in the experiment conducted in Thorney Island in 1984. Two major effects of dense gas dispersion, gravity slumping and stratification effect, are successfully incorporated into LDM (Lagrangian dense gas model). Entrainment effect is naturally modelled by introducing stochastic dispersion model with the effect of turbulence suppression by stratification. Not only various releasing conditions but also complex terrain can be extended to, although proposed model is appropriate for flat terrain.

Controllable Pretilt Angles for Liquid Crystal Molecules using a Rubbing Treated Mixture Layer

  • Kim, Dae-Hyun;Park, Hong-Gyu;Kim, Young-Hwan;Kim, Byoung-Yong;Ok, Chul-Ho;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.140-142
    • /
    • 2009
  • We have investigated the continuous pretilt angle generation for liquid crystals using a rubbing treated mixture layer consisting of homogeneous and homeotropic polyimides. Various pretilt angles in the range from $0^{\circ}$ to $60^{\circ}$ were achieved as a function of the concentration of homeotropic PI. The transmittance characteristics used to measure the pretilt angle showed that the pretilt angles were measured with a high reliability. We observed uniform liquid crystal alignment on the rubbing treated mixture layer.

Fiber optic 산소센서를 이용한 생물공정의 모니터링

  • Lee, Jong-Il;Comte, Andreas;Hung, Lam Tuan;Kim, Jun-Hong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.569-571
    • /
    • 2000
  • A fiber optic oxygen sensor has been employed to monitor the concentrations of dissolved oxygen in a bioreactor. The characteristics of fiber optic oxygen sensor was investigated, e.g. the dependency of agitation rate on the oxygen measurement and also the dependence of temperature on the performance of fiber optic oxygen sensor etc. We have also applied to monitor the concentrations of dissoved oxygen in real cultivation processes by using the fiber optic oxygens sensor. The fiber optic oxygen sensor can be applied to measure the concentration of metabolites by immobilizing some enzymes, e.g. glucose oxidase and also employed for the environmental technology.

  • PDF