• Title/Summary/Keyword: computer-assisted surgery

Search Result 81, Processing Time 0.028 seconds

Augmented reality and dynamic infrared thermography for perforator mapping in the anterolateral thigh

  • Cifuentes, Ignacio Javier;Dagnino, Bruno Leonardo;Salisbury, Maria Carolina;Perez, Maria Eliana;Ortega, Claudia;Maldonado, Daniela
    • Archives of Plastic Surgery
    • /
    • v.45 no.3
    • /
    • pp.284-288
    • /
    • 2018
  • Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.

Ideal Nasal Preferences: A Quantitative Investigation with 3D Imaging in the Iranian Population

  • Kiarash Tavakoli;Amir K. Sazgar;Arman Hasanzade;Amir A. Sazgar
    • Archives of Plastic Surgery
    • /
    • v.50 no.4
    • /
    • pp.340-347
    • /
    • 2023
  • Background Though in facial plastic surgery, the ideal nasal characteristics are defined by average European-American facial features known as neoclassical cannons, many ethnicities do not perceive these characteristics as suitable. Methods To investigate the preferences for nasofrontal angle, nasolabial angle, dorsal height, alar width, and nasal tip projection, manipulated pictures of one male and one female model were shown to 203 volunteer patients from a tertiary university hospital's facial plastic clinic. Results The most aesthetically preferred nasofrontal angles were 137.64 ± 4.20 degrees for males and 133.55 ± 4.53 degrees for females. Acute nasofrontal angles were more desirable in participants aged 25 to 44. The most preferred nasolabial angles were 107.56 ± 5.20 degrees and 98.92 ± 4.88 degrees, respectively. Volunteers aged 19 to 24 preferred more acute male nasolabial angles. A straight dorsum was the most desirable in both genders (0.03 ± 0.78 and 0.26 ± 0.75 mm, respectively). The ideal male and female alar widths were -0.51 ± 2.26 and -1.09 ± 2.18 mm, respectively. More 45- to 64-year-old volunteers preferred alar widths equal to intercanthal distance. The ideal female and male tip projections were 0.57 ± 0.01 and 0.56 ± 0.01, respectively. Conclusion Results indicate that the general Iranian patients prefer thinner female noses with wider nasofrontal angles for both genders. However, the ideal nasolabial angles, dorsal heights, and tip projections were consistent with the neoclassical cannons. Besides ethnic differences, the trend of nasal beauty is also affected by gender, age, and prior history of aesthetic surgery.

Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery (마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향)

  • Mai, Hai Yen;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.219-224
    • /
    • 2019
  • Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (${\alpha}=.05$). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of micro-screw for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

The accuracy of a 3D printing surgical guide determined by CBCT and model analysis

  • Ma, Boyoung;Park, Taeseok;Chun, Inkon;Yun, Kwidug
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2018
  • PURPOSE. The aim of this clinical study was to assess the accuracy of the implants placed using a universal digital surgical guide. MATERIALS AND METHODS. Among 17 patients, 28 posterior implants were included in this study. The digital image of the soft tissue acquired from cast scan and hard tissue from CBCT have been superimposed and planned the location, length, diameter of the implant fixture. Then digital surgical guides were created using 3D printer. Each of angle deviations, coronal, apical, depth deviations of planned and actually placed implants were calculated using CBCT scans and casts. To compare implant positioning errors by CBCT scans and plaster casts, data were analyzed with independent samples t-test. RESULTS. The results of the implant positioning errors calculated by CBCT and casts were as follows. The means for CBCT analyses were: angle deviation: $4.74{\pm}2.06^{\circ}$, coronal deviation: $1.37{\pm}0.80mm$, and apical deviation: $1.77{\pm}0.86mm$. The means for cast analyses were: angle deviation: $2.43{\pm}1.13^{\circ}$, coronal deviation: $0.82{\pm}0.44mm$, apical deviation: $1.19{\pm}0.46mm$, and depth deviation: $0.03{\pm}0.65mm$. There were statistically significant differences between the deviations of CBCT scans and cast. CONCLUSION. The model analysis showed lower deviation value comparing the CBCT analysis. The angle and length deviation value of the universal digital guide stent were accepted clinically.

Morphological analysis of maxillary sinus septum using computed tomography (컴퓨터단층촬영을 이용한 상악동 중격의 형태학적 분석)

  • Chae, Jong-Beom;Lee, Sang-Han;Kim, Chin-Soo;Kim, Jong-Bae;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • Introduction: The current study examined the morphological characteristics of maxillary sinus septum by computed tomography (CT). Materials and Methods: Two hundred and four patients (408 maxillary sinuses) who visited dental clinic were evaluated. CT were examined. The height of the septum measured from the sinus floor to the apex of the septum more than 3 mm was defined as "sinus septum". Results: The prevalence of sinus septa was 21.3% (87/408), and 31.4% (64/204) of patients had more than 1 sinus septum. Females showed higher and thinner sinus septa than males. The anatomic location of the septa were distributed in the 2nd molar region (43.7%), 1st molar region (31.0%), 2nd premolar region (21.8%) and 1st premolar region (3.5%). In 57 patients with chronic disease, there was no significant difference between sinus disease and the presence of sinus septa. The loss of remaining teeth and teeth adjacent to the sinus septum area was not related to the presence of sinus septa. Older subjects showed a reduced height and length of the septum, and a thicker septum. Conclusion: These results show that the maxillary sinus septum undergoes atrophy with age.

Novel three-dimensional position analysis of the mandibular foramen in patients with skeletal class III mandibular prognathism

  • Kang, Sang-Hoon;Kim, Yeon-Ho;Won, Yu-Jin;Kim, Moon-Key
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.77-85
    • /
    • 2016
  • Purpose: To analyze the relative position of the mandibular foramina (MnFs) in patients diagnosed with skeletal class III malocclusion. Materials and Methods: Computed tomography (CT) images were collected from 85 patients. The vertical lengths of each anatomic point from the five horizontal planes passing through the MnF were measured at the coronoid process, sigmoid notch, condyle, and the gonion. The distance from the anterior ramus point to the posterior ramus point on the five horizontal planes was designated the anteroposterior horizontal distance of the ramus for each plane. The perpendicular distance from each anterior ramus point to each vertical plane through the MnF was designated the horizontal distance from the anterior ramus to the MnF. The horizontal and vertical positions were examined by regression analysis. Results: Regression analysis showed the heights of the coronoid process, sigmoid notch, and condyle for the five horizontal planes were significantly related to the height of the MnF, with the highest significance associated with the MnF-mandibular plane (coefficients of determination ($R^2$): 0.424, 0.597, and 0.604, respectively). The horizontal anteroposterior length of the ramus and the distance from the anterior ramus point to the MnF were significant by regression analysis. Conclusion: The relative position of the MnF was significantly related to the vertical heights of the sigmoid notch, coronoid process, and condyle as well as to the horizontal anteroposterior length of the ascending ramus. These findings should be clinically useful for patients with skeletal class III mandibular prognathism.

Evaluation of alveolar bone grafting in unilateral cleft lip and palate patients using a computer-aided diagnosis system

  • Sutthiprapaporn, Pipop;Tanimoto, Keiji;Nakamoto, Takashi;Kongsomboon, Supaporn;Limmonthol, Saowaluck;Pisek, Poonsak;Keinprasit, Chutimaporn
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.225-229
    • /
    • 2012
  • Purpose: This study aimed to evaluate the trabecular bone changes after alveolar bone grafting in unilateral cleft lip and palate (UCLP) patients using a computer-aided diagnosis (CAD) system. Materials and Methods: The occlusal radiographs taken from 50 UCLP patients were surveyed retrospectively. The images were categorized as: 50 images in group 0 (before bone grafting), 33 images in group 1 (one month after bone grafting), 24 images in group 2 (2-4 months after bone grafting), 15 images in group 3 (5-7 months after bone grafting), and 21 images in group 4 (8 or more months after bone grafting). Each image was grouped as either "non-cleft side" or "cleft side". The CAD system was used five times for each side to calculate the pixel area based on the mathematical morphology. Significant differences were found using a Wilcoxon signed ranks test or paired samples t test. Results: The pixel area showed a significant difference between the "non-cleft side" and "cleft side" in group 0 ($404.27{\pm}103.72/117.73{\pm}92.25$; p=0.00), group 1 ($434.29{\pm}86.70/388.31{\pm}109.51$; p=0.01), and group 4 ($430.98{\pm}98.11/366.71{\pm}154.59$; p=0.02). No significant differences were found in group 2 ($423.57{\pm}98.12/383.47{\pm}135.88$; p=0.06) or group 3 ($433.02{\pm}116.07/384.16{\pm}146.55$; p=0.19). Conclusion: Based on the design of this study, alveolar bone grafting was similar to normal bone within 2-7 months postoperatively.

Usefulness of Intravenous Anesthesia Using a Target-controlled Infusion System with Local Anesthesia in Submuscular Breast Augmentation Surgery

  • Chung, Kyu-Jin;Cha, Kyu-Ho;Lee, Jun-Ho;Kim, Yong-Ha;Kim, Tae-Gon;Kim, Il-Guk
    • Archives of Plastic Surgery
    • /
    • v.39 no.5
    • /
    • pp.540-545
    • /
    • 2012
  • Background Patients have anxiety and fear of complications due to general anesthesia. Through new instruments and local anesthetic drugs, a variety of anesthetic methods have been introduced. These methods keep hospital costs down and save time for patients. In particular, the target-controlled infusion (TCI) system maintains a relatively accurate level of plasma concentration, so the depth of anesthesia can be adjusted more easily. We conducted this study to examine whether intravenous anesthesia using the TCI system with propofol and remifentanil would be an effective method of anesthesia in breast augmentation. Methods This study recruited 100 patients who underwent breast augmentation surgery from February to August 2011. Intravenous anesthesia was performed with 10 mg/mL propofol and 50 ${\mu}g/mL$ remifentanil simultaneously administered using two separate modules of a continuous computer-assisted TCI system. The average target concentration was set at 2 ${\mu}g/mL$ and 2 ng/mL for propofol and remifentanil, respectively, and titrated against clinical effect and vital signs. Oxygen saturation, electrocardiography, and respiratory status were continuously measured during surgery. Blood pressure was measured at 5-minute intervals. Information collected includes total duration of surgery, dose of drugs administered during surgery, memory about surgery, and side effects. Results Intraoperatively, there was transient hypotension in two cases and hypoxia in three cases. However, there were no serious complications due to anesthesia such as respiratory difficulty, deep vein thrombosis, or malignant hypertension, for which an endotracheal intubation or reversal agent would have been needed. All the patients were discharged on the day of surgery and able to ambulate normally. Conclusions Our results indicate that anesthetic methods, where the TCI of propofol and remifentanil is used, might replace general anesthesia with endotracheal intubation in breast augmentation surgery.

Cone-beam computed tomography texture analysis can help differentiate odontogenic and non-odontogenic maxillary sinusitis

  • Andre Luiz Ferreira Costa;Karolina Aparecida Castilho Fardim;Isabela Teixeira Ribeiro;Maria Aparecida Neves Jardini;Paulo Henrique Braz-Silva;Kaan Orhan;Sergio Lucio Pereira de Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: This study aimed to assess texture analysis(TA) of cone-beam computed tomography (CBCT) images as a quantitative tool for the differential diagnosis of odontogenic and non-odontogenic maxillary sinusitis(OS and NOS, respectively). Materials and Methods: CBCT images of 40 patients diagnosed with OS (N=20) and NOS (N=20) were evaluated. The gray level co-occurrence (GLCM) matrix parameters, and gray level run length matrix texture (GLRLM) parameters were extracted using manually placed regions of interest on lesion images. Seven texture parameters were calculated using GLCM and 4 parameters using GLRLM. The Mann-Whitney test was used for comparisons between the groups, and the Levene test was performed to confirm the homogeneity of variance (α=5%). Results: The results showed statistically significant differences(P<0.05) between the OS and NOS patients regarding 3 TA parameters. NOS patients presented higher values for contrast, while OS patients presented higher values for correlation and inverse difference moment. Greater textural homogeneity was observed in the OS patients than in the NOS patients, with statistically significant differences in standard deviations between the groups for correlation, sum of squares, sum of entropy, and entropy. Conclusion: TA enabled quantitative differentiation between OS and NOS on CBCT images by using the parameters of contrast, correlation, and inverse difference moment.

Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study

  • Phyo Ei Ei Htay;Richard Leesungbok;Suk Won Lee;Yu-Jin Jee;Kyung Lhi Kang;Sung Ok Hong
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.259-270
    • /
    • 2023
  • PURPOSE. This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS. Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS. There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists' groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION. CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits.