Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.
A 32-year-old woman diagnosed with Turner syndrome presented to the hospital for an evaluation of cardiovascular complications. Preoperative computed tomography (CT) and echocardiography showed progression of aortic root and ascending aorta dilatation, as well as a bicuspid aortic valve. There was no evidence of aortic regurgitation. We planned valve-sparing aortic root replacement and ascending aorta replacement with a high risk of aortic rupture. Intraoperatively, we incidentally found a juxtacommissural origin of the right coronary artery (RCA). We performed aortic valve reimplantation using a graft designed with a key-shaped hole to wrap the juxtacommissural-origin RCA by modifying the Florida sleeve technique. Coronary blood flow was patent on postoperative CT angiography, and there was no evidence of aortic regurgitation on postoperative echocardiography. The patient was discharged from the hospital on postoperative day 7 without any complications.
The vascular anatomy of the deep inferior epigastric artery perforator (DIEP) flap has been well studied in the planning for autologous breast reconstruction. Preoperative imaging with computed tomography angiography (CTA) provides accurate assessment of this vascular anatomy, which varies widely across patients. Several papers to date have described their encounter with an anomalous "epiperitoneal" or "peritoneo-cutaneous" perforator during flap harvest, a perforator that pierces the posterior rectus sheath from a peritoneal origin, to traverse rectus abdominis and supply the DIEP flap integument. In the course of over 3,000 CTA assessments of the vascular anatomy of the abdominal wall, we have encountered dominant peritoneo-cutaneous perforators in 1% of cases, and smaller perforators seen in many more cases, approaching 5% of cases. With increasing sensitivity of imaging, we also describe a unique case of multiple large bilateral peritoneo-cutaneous perforators, and present these findings in the context of DIEP flap harvest. It is critical to recognize these peritoneo-cutaneous perforators preoperatively to avoid mistaking them for a DIEP during the raising of a DIEP flap. The routine use of preoperative CTA enables the safe identification of individual vascular anatomy, including significant peritoneo-cutaneous perforators.
개에서 실험적으로 편측성 신수종증을 유발한 후, 이오헥솔-에탄올 용액을 신장동맥내로 주입하여 신수종증이 유발된 신장으로의 혈류를 차단하는 신동맥 색전술을 실시하고, 선택적 동맥촬영술, 조영증강 전산화 단층촬영, 이용하여 색전술이 실시된 신수종증의 신장과 반대편 정상신장을 평가하고자 본 실험을 실시하였다. 실험적 수신증은 2두의 비글견의 편측 근위 요관을 이중결찰하여 유발하였으며 개에서 요관 결찰 17일째에 편측성 수신증이 유발되었음을 확인할 수 있었다. 신장동맥 색전술은 2두의 신수종증이 유발된 신장측의 신장동맥에 대퇴동맥을 통하여 선택적으로 카테터를 삽입한 후 이오헥솔-에탄올 용액을 주입하였으며, 시술 중 심전도, 산소포화도, 체온, 맥박, 호흡수는 모두 정상범위에 있었다. 신장동맥 색전술 후 사망한 개체는 없었으며, 색전물질의 유출로 인한 부작용도 관찰할 수 없었다. 색전술 직후 그리고 14일째에 실시한 선택적 동맥촬영술을 통하여 색전술을 시행한 2두의 개의 신장동맥에서 재맥관화가 발생하지 않았음을 확인할 수 있었다. 실험군의 2두와 대조군의 1두에서 실시한 전산화단층촬영상에서는 색전술 실시 후 14일째에 실험군과 대조군의 신장의 신우부가 확장되고 확장된 신장에 의해 비장이 복측으로 변위된 것을 확인할 수 있었으며, 색전술 실시 후 두 달째의 소견에서는 색전된 신장의 크기가 감소한 것을 확인할 수 있었다. 조영제 증강 전산화단층촬영에서는 색전술을 실시하지 않은 신장피질의 신호강도가 증가하는 것을 관찰할 수 있었으나, 색전술을 실시한 신장피질의 신호강도는 증가하지 않았다. 따라서, 조영 증강 전산화 단층촬영은 개의 수신증에 실시한 신장동맥 색전술 후의 신장동맥의 재맥관화를 평가할 수 있는 유용한 검사법으로 사료된다.
배 경: 폐색전증의 임상증상은 비특이적이어서 임상증상 만으로 진단이 어렵다. 폐색전증의 진단을 위하여 폐환기관류주사가 선별검사로 널리 사용되고 있으나 PIOPED(the prospective investigation of pulmonary embolism diagnosis) 연구의 결과처럼 저 중등도 확률 소견일 경우 폐색전증의 진단을 내리거나 배제하는데 도움이 되지 않으며 PIOPED 연구의 약 60%의 환자가 저 중등도 확률 소견을 보인다. 이러한 환자들은 확진을 위해 폐동맥조영술이 필요하지만 침습적이며 쉽게 시행할 수 없다는 단점이 있다. 최근 가공 영상을 줄이고 조영제 일시주사 기술로 혈관구조를 조영할 수 있게 한 spiral CT가 폐동맥조영술을 대신하여 폐색전증의 진단에 이용하는 전향적 연구가 이루어지고 있다. 이에 저자들은 폐색전증의 진단에서 spiral CT의 유용성을 알아보고자 폐색전증을 의심하여 spiral CT를 찍은 환자를 대상으로 후향적 조사를 시행하였다. 방 법: 1994년 10월부터 1997년 2월까지 삼성서울병원에 입원한 환자 중 폐색전증이 의심되어 spiral CT를 시행한 20명(남자 : 13명, 여자 : 7명, 평균연령 : 58세)을 대상으로 하였다. 폐색전증의 위험인자로 심부정맥혈전증과 고령이 가장 많았고 폐색전증이 의심된 임상증상으로 갑자기 발생하였거나 악화된 호흡곤란이 가장 많았다. 결 과: 20명의 환자 중 spiral CT로 폐색전증으로 진단된 환자는 16명이었고 3명은 각각 폐암, 폐기종 환자에서 발생한 폐농양을 동반한 폐렴, 울혈성 심부전에 의한 흉막삼출증으로 색전을 확인할 수 없었다. 나머지 1명은 spiral CT에서 정상 소견이었다. 폐환기관류주사에서 고확률로 판정된 12명의 환자중 1명에서 spiral CT로 폐기종 환자에서 발생한 폐농양을 동반한 폐렴인 위양성으로 진단할 수 있었다. 폐환기관류주사에서 저 중동도 확률을 보이는 4명 중 3명에서 spiral CT로 폐색전증을 진단할 수 있었다. 야간, 기계호흡 등의 이유로 폐환기관류주사를 시행치 못한 3명에서 spiral CT로 폐색전증을 진단 또는 배제할수 있었다. 폐색전증으로 진단된 16명 중에서 폐엽동맥 수준 이상의 색전은 11례 였으며 분절하동맥 수준 이하의 색전 경우는 5례였다. 결 론: 이상의 결과로 spiral CT는 폐분절동맥까지의 폐색전증의 진단에 유용하며, 특히 중심성 폐색전증의 확진과 배제에 있어서 중요한 진단방법이라고 생각된다. 향후 폐색전증의 진단에 spiral CT가 진단과정에 도입될 수 있는지에 대한 대규모의 전향적인 연구가 필요할 것으로 사료된다.
Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.
Blunt cerebrovascular injury is defined as a vertebral or carotid arterial structural wall injury resulting from nonpenetrating trauma. Complete traumatic internal carotid artery occlusion is very rare condition accounting for 0.08~0.4 0f all trauma patients and believed to be associated with the greatest risk of ischemic stroke reported in 50~90% in a few small series. A 55-year-male was admitted with drowsy mentality and severe headache after a fall down accident. Brain computed tomography showed a subdural hematoma at the both frontal area with a fracture of the occipital skull bone. Two days after admission, he suddenly complained with a right side hemiparesis of motor grade 2. Brain magnetic resonance diffusion demonstrated multiple high flow signal changes from the left frontal and parietal lesion. Computed tomographic angiogram (CTA) revealed absence of the left ICA flow. Trans femoral cerebral angiography (TFCA) showed complete occlusion of the left internal carotid artery (ICA) at ophthalmic segment in the left ICA angiogram and flows on the left whole hemispheric lesions through the anterior communicating artery in the right ICA angiogram. We decided to conduct close observations as a treatment for the patient because of acute subdural hematoma and sufficient contralateral cerebral flow by perfusion SPECT scan. Two weeks after the accident, he was treated with heparin anticoagulation within INR 2~4 ranges. He recovered as the motor grade 4 without another neurologic deficit after 3 months.
최근 혈관 질환의 진단을 위한 비침습적 영상이 발달하면서, 기존의 도자술은 중재적 치료에 국한되는 실 정이다. 그러나 관상동맥이나 우회로는 작은 직경, 심박동 움직임 등으로 도자술이 아직도 진단에 필수적이 며, 비침 응\ulcorner영상 진단의 마지막 도전 영역이다. 전자선 단층 촬영기는 높은 시간 해상능으로 심장 영상을 얻을 수 있다. 전자선 단층 촬영을 이용하여 모관상 동맥 협착이나 관상동맥 우회로 이식술 후 개존성의 평 가가 시도되고 있으며, 이중 관상동맥 우회로술 평가의 정확도는 매우 높아서 임상 적용이 가능하다. 저자와 다른 연구자의 경험에 의하면 복재 정맥은 넓은 직경, 비교적 짧고 직선적인 경로, 심박동에 덜 영 향 받음으로써 EBT조영술의 정확도가 높았다. 전향적 민감도와 특이도가 각각 92%, 97%를 보였다. 그러나 위양성과 위음성을 보인 두 예는 후향적으로 분석 할 때 경험 부족에 의한 초기의 판독 오류로 사료되어 복 재 정맥의 경우 후향적으로는 100%의 정확도를 보였다. 반면 내유동맥 이식혈관은 작은 내경과 주변의 수술 클립에 의한 인공산물로 개존성을 확인하기가 대체로 어려웠고, 역동적 검사를 병행하여 우회로내 혈류를 확인하는 것이 필요하다. 내유동맥의 경우 상대적으로 정확도가 낮아 민감도, 특이도가 각각 100%, 80%를 보였으며, 위양성을 보인 2예는 후향적으로도 개존을 확인할 수 없었다. 전자선 단층 촬영 혈관 조영술은 관상 동맥 우 막\ulcorner이식술 후의 우회 혈관 개존성의 평가, 특히 복재 정맥 우회로의 경우 매우 정확도가 높은 비침습적 검사로써, 임상 적용이 기대된다. 앞으로 촬영 기기와 영상 재구성 software의 발달로 정확도를 더욱 높일 수 있는 잠재성이 있다.
배경: 전산화 단층촬영은 흉부대동맥의 이상소견을 진단하는데 매우 중요한 수단이다. 그러나 재래의 전산화 단층좔영은 단면적인 영상만을 볼 수 있어 여러 부위의 대동맥 직경을 측정하기에는 한계가 있었다. 다중검출 전산화 단층촬영은 이러한 한계를 극복할 수 있는 진단기기로 이를 이용하여 곡선으로 된 흉부대동맥의 직경을 주행방향과 직각으로 측정하여 연령, 성별, 키와 몸무게, 체표면적과 체질량지수, 고혈압과의 관계를 알아보고자 하였다. 대상 및 방법: 다중검출 전산화 단층촬영 장비를 이용하여 대동맥 조영술을 시행한 환자 중 특별한 대동맥 질환이 없는 것으로 판독된 환자 331명을 대상으로 하였으며, 남자가 141명이고 여자가 190명이었다. 이들을 연령별로 20~39세, 40~59세, 60세 이상으로 분류하였다. 대동맥의 직경은 다면상으로 재구성한 단면에서 대동맥 주행방향과 직각이 되도록 측정하였으며 상행대동맥의 중간(level A), 원위부 상행대동맥(level B), 대동맥궁(level C), 대동맥 협부(level D), 하행대동맥의 중간(level E)의 다섯 군데에서 측정하였다. 결과: 대상환자의 평균연령은 남자가 49.5세이고 여자가 54.9세였다. 대동맥의 평균직경은 level A가 31.1 mm, level B가30.2 mm, level C가 26.5 mm, level D가 24.0 mm, level E가 22.6 mm였다. 대동맥의 직경은 나이에 비례해서 증가하는 양상을 보였으며 고혈압 환자가 정상인보다 대동맥의 직경이 크게 나타났다. 키와 체표면적에 따른 차이는 상행대동맥에서 유의하게 나타났고 대동맥궁과 하행대동맥은 유의한 차이가 없었다. 체중과 체질량지수는 모든 부위에서 통계적 유의성이 없었다. 결론: 흉부대동맥의 직경은 성별과 나이, 고혈압에 통계적으로 유의한 차이가 있었고 키와 체표면적은 상행대동맥에만 차이를 보였고 하행대동맥에는 차이가 없었다. 그리고 체중과 체질량지수는 모든 부위에서 통계적 유의성이 없었다. 본 연구에서는 고혈압이 없는 정상인에서 연령별 대동맥 직경의 표준값과 정상한계값을 측정하였고 이를 한국인의 흉부대동맥 직경의 참고자료로 제시하고자 한다.
상장간맥동맥 증후군은 일반적인 검사에서 매우 탐지가 어려운 십이지장 만성폐색의 원인으로 대두되고 있다. 그러므로, 십이지장의 횡행부가 상장간막동맥과 복부대동 사이를 지나가기 때문에 복부대동맥과 상장간맥동맥 사이의 각도가 좁아져 십이지장 폐색의 원인을 야기시킨다. 이 각도의 측정은 일반혈관촬영으로는 복잡하고, 종종 부정확한 결과를 초래한다. 또한 한국인을 기준으로 각도 측정에 관한 시도 및 자료가 없는 실정이다. 따라서 본 연구자는 3차원 영상재구성을 위하여 범용컴퓨터에서 실행 가능한 Rapidia S/W를 이용함으로써 복부대동맥으로부터 상장간막동맥기시부의 각도를 측정하였는데, 상장간막동맥증후군이 없는 일반 환자를 대상으로 복부전산화단층촬영의 3차원영상을 이용하였다. 이 실험의 결과 상장간막동맥과 복부대동맥의 평균각도는 $50.05{\pm}15.87^{\circ}$이고 남자의 평균각도는 $53.64{\pm}16.57^{\circ}$이고 여자는 $46.46{\pm}14.98^{\circ}$로 남자의 각도가 약간 더 크게 나타났다. 이러한 연구를 통하여 얻은 각도가 상장간막동맥 증후군의 진단하는데 매우 중요한 지표가 될 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.