• Title/Summary/Keyword: compound electrode

Search Result 127, Processing Time 0.023 seconds

Characteristics of Grounding Impedances of Carbon Compound Grounding Electrodes (탄소혼합물 접지전극의 접지임피던스의 특성)

  • Lee, Kang-Soo;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.54-60
    • /
    • 2011
  • This paper presents characteristics of frequency-dependent grounding impedance and transient grounding impedance for the carbon compound grounding electrode used in the installation of computerized electronic equipment and lightning protection system. The frequency-dependent grounding impedances were measured by applying sinusoidal currents in the frequency range from 100 [Hz] to 10[MHz], and the transient grounding impedances were examined by subjecting the impulse current with the front-time between 1~80[${\mu}s$]. As a result, the ground resistance of the carbon compound grounding electrode is less than that of another type grounding electrodes. The transient grounding impedance is relatively low and the conventional grounding impedance is rather lower than the ground resistance. The frequency-dependent grounding impedance of the carbon compound grounding electrode is capacitive and the grounding impedance is decreased with increasing the frequency of injected currents. Therefore in the case that the carbon compound grounding electrode is jointly used with large-scaled grounding electrodes, it is possible to reduce the high frequency grounding impedance of the integrated grounding electrode system.

SKIN IMPEDANCE MEASUREMENTS USING COMPOUND ELECTRODES (복합형 전극을 이용한 피부의 전기저항 측정)

  • Woo, Eung-Je
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.98-100
    • /
    • 1991
  • We studied the characteristics of the compound electrode and found that the compound electrode provides the four-electrode method in a compact form. We developed a new method of measuring the skin impedance using simple electrodes at low frequencies. At high frequencies where the effect of internal tissue impedance is not negligible, we used the compensation method using compound electrodes since they measure the voltage right under the skin. At 50 kHz, we measured the real part of the skin impedance of less than $80\;{\Omega}$ on the thorax.

  • PDF

A Study of Skin Resistance of Jeong-Acupuncture Points Using the Compound Electrode (복합전극을 이용한 정혈의 최대피부저항특성에 관한 연구)

  • 최진욱;최귀원;박영배
    • The Journal of Korean Medicine
    • /
    • v.24 no.1
    • /
    • pp.100-109
    • /
    • 2003
  • Objectives : The purpose of this study is to 1. measure the skin resistance of jeong-acupuncture points using compound electrode, and 2. develop a database of skin resistance based on age and gender. Methods : The skin resistance of jeong-acupuncture points on the hands and feet of 191 healthy volunteers was measured using a specially designed compound electrode. A constant current of $5{\mu\textrm{A}}$ was applied to the measurement points and the skin resistance was obtained using amplifier, A/D converter and Acknowledge software program, Results : 1. ANOVA statistical analysis showed no significant differences between jeong-acupuncture points on hands and feet. 2. Paired samples t-test showed no significant differences between Yin-Yang meridian points, 3. When the data were sorted by gender, factor analysis showed statistically significant differences between male and female groups in all measured points except for left foot. 4. Based on the factor analysis, a significant relationship between the skin resistance and age was found in feet. However, no such relationship was found in hands. Conclusions : There are differences in skin resistance according to sex and age, Further clinical research is necessary using compound electrode method.

  • PDF

Skin Impedance Measurements Using the Characteristics of Compound Electrode (복합형 전극의 특성을 이용한 피부의 전기저항 측정에 관한 연구)

  • 우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.47-54
    • /
    • 1992
  • We studied the characteristics of the compound electrode and found that the compound electrode provides the four-electrode method in a compact form. We developed a new method of measuring the skin impedance using simple electrodes at low frequencies. At high frequencies where the effect of internal tissue impedance is not negligible, we used the compensation method using compound electrodes since they measure the voltage right under the skin. At 50 kHz, we measured the real part of the skin impedance of less than $80{\Omega}$ on the thorax. We propose a simple instrument which can measure accurate skin impedance at various frequencies.

  • PDF

The Influence of the Reference Electrode on Compound Muscle Action Potential Onset Latency and Amplitude (복합근육활동전위의 시작잠복기와 진폭에 대한 기준전극의 영향)

  • Lee, Sang-Moo;Choi, Heui-Chul;Son, Jong-Hee
    • Annals of Clinical Neurophysiology
    • /
    • v.12 no.1
    • /
    • pp.11-15
    • /
    • 2010
  • Background: In belly-tendon (bipolar) montage, reference (R2) electrode placed on muscle's tendon has traditionally been considered to be electrically inactive. However, recent studies have revealed that R2 electrode is not simply referential, but actively contributes to compound muscle action potential (CMAP) waveform morphology. These findings suggest that CMAP onset latency and amplitude may also be influenced by the position of R2 electrode. This study was performed in order to evaluate the effect of R2 electrode position on CMAP onset latency and amplitude. Methods: We performed motor nerve conduction studies of median, ulnar, tibial and peroneal nerves on bilateral limbs of 20 normal subjects. We used traditional bipolar and monopolar montage and compared their CMAP onset latencies and amplitudes. In bipolar montage, recording (R1) electrode was placed on mid-belly of muscle with R2 electrode on the tendon of the muscle. In monopolar montage, R1 electrode was placed on the same site of bipolar montage, while R2 electrode was placed on the contralateral limb. Results: The mean CMAP onset latencies of median and peroneal nerves in bipolar montage were significantly different (p<0.05) with those in monopolar montage. And those of ulnar and tibial nerves were not significantly different (p>0.05). The mean CMAP amplitudes of all the tested nerves except ulnar nerve were significantly different (p<0.05). Conclusions: This study shows that change in R2 electrode position can affect the CMAP onset latency and amplitude, and these differences seem to be related to the generation of far field potential by CMAP.

Study of Laryngeal Evoked Electromyography Method in Rats (백서를 이용한 후두 유발 근전도 검사 방법에 대한 연구)

  • 조선희;이재연;민선식;신유리;정성민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.2
    • /
    • pp.178-184
    • /
    • 2000
  • Laryngeal evoked EMG is the objective and quantitative method to measure the innervation of laryngeal muscle. If there is a mobility disorder of vocal cords, the cause and location of neural lesion co be understood by the laryngeal evoked EMG and if there is a vocal cord paralysis, the degree of recovery and the policy of treatment can be determined by it. Recently, the studies of reinnervation after recurrent laryngeal nerve injury have been actively carried out. Laryngeal evoked EMC is useful to these studies. The aim of study is to know whether noninvasive methods for stimulating the recurrent laryngeal nerve and for recording of compound action potential(CAP) using surface electrode are as useful as the invasive method using needle electrode. We obtained EMG of laryngeal muscle by various stimulating and recording methods : 1) Direct nerve stimulation by placing nerve cuff electrode made out of silastic tube and platinum wire and recording by insertion of hook wire electrode into posterior cricoarytenoid(PCA) and thyroarytenoid(TA) muscles, respectively. 2) Recording of compound action potential by surface electrode after stimulation of recurrent laryngeal nerve by the insertion of 27 gauge of needle electrode. 3) Recording of compound action potential by surface electrode after stimulating the recurrent laryngeal nerve by transcutaneous blunt rod electrode at tracheoesophageal groove. The amplitude, duration and latency of the CAP evoked by recurrent laryngeal nerve stimulation were compared among the three groups. The amplitude of CAP was smallest in the group recorded from posterior cricoarytenoid and hyroarytenoid muscle, and that recorded by surface electrode after stimulation by needle electrode was largest. The difference in amplitude between the group by hook wire recording and the two groups by surface electrode recording was significant statistically. There is no significant difference in duration and latency among three groups. Since the waveform of CAP from all three methods has similar duration, latency, we concluded that noninvasive method is a useful as invasive methods.

  • PDF

Se Electrode for Low Surge Vacuum Circuit Breaker (저surge 진공 차단기용 Se 전극 제조)

  • Kim, Bong-Seo;Woo, Byung-Chul;Byun, Woo-Bong;Lee, Hee-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1651-1653
    • /
    • 1996
  • As electrode materials like as Cu-Pb, Cu-Bi, WC-Ag, W-Ag for vacuum circuit breaker have high chopping current or bad insulation-recovery characteristics, it can affect induction machinery like as transformer and motor. To produce low surge electrode material, it have been suggested Co-Ag-Se electrode which were infiltrated with Ag-Se intermetallic compound into sintered Co matrix. In this study, we would like to represent that production method and microstructure of Co-Ag-Se electrode material. The microstructure and characteristics of Ag-Se intermetallic compound and Co-(Ag-Se) electrode were investigated by using SEM, XRD, EPMA.

  • PDF

Production of Te Electrode for Low Surge Vacuum Circuit Breaker (저surge 진공 차단기용 Te 전극 제조)

  • 김봉서;우병철;변우봉;이희웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.123-128
    • /
    • 1996
  • As electrode materials like as Cu-Pb, Cu-Bi, WC-Ag, W-Ag for vacuum circuit breaker have high chopping current or bad insulation-recovery characteristics, it can affect induction machinery like as transformer and motor. To produce low surge electrode material, it have been suggested Co-Ag-Te electrode which were infiltrated with Ag-Te intermetallic compound into sintered Co matrix in vacuum. In this paper, we would like to represent that production method and microstructure of Co-Ag-Te electrode material in each condition. The microstructure and characteristics of Ag-Te intermetallic compound and Co-(Ag-Te) electrode were investigated by using optical microscope, SEM, XRD, EPMA.

  • PDF

Direct Acid Leaching of Zinc from Marmatite Ores 3 Acid Leaching of Marmatite Ores and the Electrode Potential Behavior of Sulfides (Marmatite 鑛의 直接酸浸出에 關한 硏究 (第3報) Marmatite 鑛의 酸浸出과 黃化物의 電極電位에 關한 硏究)

  • Kim Jae Won
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.1
    • /
    • pp.38-43
    • /
    • 1967
  • In order to explain the positive catalytic action of copper compound for the rate of leaching of zinc sulfide minerals, the electrode and redox potentials of both synthetic and natural sulfides were measured at various conditions of temperatures and pressures. The potentials of Chalcopyrite and copper sulfide were considerably higher than that of zinc sulfide, whereas lead sulfide and Galena had slightly lower potentials than that of zinc sulfide. At elevated temperatures and pressures, the same tendency was obtained. By means of comparing the calculated and measured values of potentials for sulfides, it was suggested that the electrode potentials in acid solution were generated by oxidation of sulfur ion. As a result, it was concluded that the catalytic action of copper compound in the leaching of synthetic zinc sulfide should be arised from the galvanic action between sulfides keeping intimate contact one another in which copper sulfide worked as cathodic and zinc sulfide as anodic part analogous to the metal corrosion under galvanic action.

  • PDF

The Potentiometric Studies on the Effects of Various Functional Groups in Disiloxane as an Anion-Selective Ionophore

  • Jung, Hyo-Jin;Lee, Myong-Euy;Lim, Chae-Yun;Paeng, Ki-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.1
    • /
    • pp.57-62
    • /
    • 2005
  • The potentiometric responses for various anions are investigated with membrane electrode (membrane 1) based on 1,3-diethyl-1,3-dihydroxy-1,3-bis(2-dimethylaminomethyl ferrocenyl) disiloxane. The nitrate ion-selective electrode based on compound 1 gave a good Nernstian response of 58.18 mV per decade for nitrate with the detection limit of −e5.66 of log [NO3−e]. Compound 1 has all those functional groups and the other two compounds have less functional group of ferrocenyl or ferrocenyl and hydroxide, respectively. Even though, potentiometric response to anions was excellent at pH 5, the selectivity pattern for all three membrane electrode based on series of disiloxane is almost like Hofmeister sequence at pH 5. However, the membrane electrode 1-3 exhibited very different response to anions at pH 7. In this pH, NH2 is not protonated and ionophore may act as neutral carrier. Hydrogen bond may enhance the responsibility to hydrogen acceptors and intramolecular electro-active site may increase the permeability of analyte to ionophore in membrane.