• Title/Summary/Keyword: complex segment

Search Result 174, Processing Time 0.036 seconds

ST-Segment Analysis of ECG Using Polynomial Approximation (다항식 근사를 이용한 심전도의 ST-Segment 분석)

  • Jeong, Gu-Young;Yu, Kee-Ho;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.8
    • /
    • pp.691-697
    • /
    • 2002
  • Myocardial ischemia is a disorder of cardiac function caused by insuficient blood flow to the muscle tissue of the heart. We can diagnose myocardial ischemia by observing the change of ST-segment, but this change is temporary. Our primary purpose is to detect the temporary change of the 57-segment automatically In the signal processing, the wavelet transform decomposes the ECG(electrocardiogram) signal into high and low frequency components using wavelet function. Recomposing the high frequency bands including QRS complex, we can detect QRS complex more easily. Amplitude comparison method is adopted to detect QRS complex. Reducing the effect of noise to the minimum, we grouped ECG by 5 data and compared the amplitude of maximum value. To recognize the ECG .signal pattern, we adopted the polynomial approximation partially and statistical method. The polynomial approximation makes possible to compare some ECG signal with different frequency and sampling period. The ECG signal is divided into small parts based on QRS complex, and then, each part is approximated to the polynomials. After removing the distorted ECG by calculating the difference between the orignal ECG and the approximated ECG for polynomial, we compared the approximated ECG pattern with the database, and we detected and classified abnormality of ECG.

Phonological Status of Korean /w/: Based on the Perception Test

  • Kang, Hyun-Sook
    • Phonetics and Speech Sciences
    • /
    • v.4 no.3
    • /
    • pp.13-23
    • /
    • 2012
  • The sound /w/ has been traditionally regarded as an independent segment in Korean regardless of the phonological contexts in which it occurs. There have been, however, some questions regarding whether it is an independent phoneme in /CwV/ context (cf. Kang 2006). The present pilot study examined how Korean /w/ is realized in $/S^*wV/$ context by performing some perception tests. Our assumption was that if Korean /w/ is a part of the preceding complex consonant like $/C^w/$, it should be more or less uniformly articulated and perceived as such. If /w/ is an independent segment, it will be realized with speaker variability. Experiments I and II examined the identification rates as "labialized" of the spliced original stimuli of $/S^*-V/$ and $/S^{w*}-^wV/$, and the cross-spliced stimuli $/S^{w*}-V/$ and $/S^*-^wV/$. The results showed that round qualities of /w/ are perceived at significantly different temporal point with speaker and context variability. We therefore conclude that /w/ in $/S^*wV/$ context is an independent segment, not a part of the preceding segment. Full-scale examination of the production test in the future should be performed to verify the conclusion we suggested in this paper.

Segment Join Technique for Processing in Queries Fast (빠른 XML질의 처리를 위한 세그먼트 조인 기법)

  • ;Moon Bongki;Lee Sukho
    • Journal of KIISE:Databases
    • /
    • v.32 no.3
    • /
    • pp.334-343
    • /
    • 2005
  • Complex queries such as path alld twig patterns have been the focus of much research on processing XML data. Structural join algorithms use a form of encoded structural information for elements in an XML document to facilitate join processing. Recently, structural join algorithms such as Twigstack and TSGeneric- have been developed to process such complex queries, and they have been shown that the processing costs of the algorithms are linearly proportional to the sum of input data. However, the algorithms have a shortcoming that their processing costs increase with the length of a queery. To overcome the shortcoming, we propose the segment join technique to augment the structural join with structural indexes such as the 1-Index. The SegmentTwig algorithm based on the segment join technique performs joins between a pair of segments, which is a series of query nodes, rather than joins between a pair of query nodes. Consequently, the query can be processed by reading only a query node per segment. Our experimental study shorts that segment join algorithms outperform the structural join methods consistently and considerably for various data sets.

Signaling Protein Complex Formation in Detergent Resistant Membrane of Bovine Photoreceptor Rod Outer Segments

  • Liu, Han;Seno, Keiji;Hayashi, Fumio
    • Journal of Photoscience
    • /
    • v.9 no.2
    • /
    • pp.275-277
    • /
    • 2002
  • We have recently found that a detergent-resistant raft like membrane (DRM) can be prepared from bovine rod outer segment membranes as a low-density buoyant fraction in sucrose density gradient ultracentrifugation. G protein (transducin) and its effector enzyme (phosphodiesterase: PDE) drastically change their affinities to DRM in the process of phototransduction. We report here that the recruitment of transducin and/or $^2$PDE to DRM has close relationship with their states in signal transduction. Active T$\alpha$/PDE-complex has a high affinity to DRM, whereas inactive transducin, or inactive PDE are excluded from DRM. Active T$\alpha$/PDE-complex seems to bind to a GTPase activating protein (GRS9) in multi- protein complexes localized on DRM. Physiological significance of the multi-protein complex on the raft-like membrane in vertebrate phototransduction would be discussed.

  • PDF

Free vibration analysis of uniform and stepped functionally graded circular cylindrical shells

  • Li, Haichao;Pang, Fuzhen;Du, Yuan;Gao, Cong
    • Steel and Composite Structures
    • /
    • v.33 no.2
    • /
    • pp.163-180
    • /
    • 2019
  • A semi analytical method is employed to analyze free vibration characteristics of uniform and stepped functionally graded circular cylindrical shells under complex boundary conditions. The analytical model is established based on multi-segment partitioning strategy and first-order shear deformation theory. The displacement functions are handled by unified Jacobi polynomials and Fourier series. In order to obtain continuous conditions and satisfy complex boundary conditions, the penalty method about spring technique is adopted. The solutions about free vibration behavior of functionally graded circular cylindrical shells were obtained by approach of Rayleigh-Ritz. To confirm the dependability and validity of present approach, numerical verifications and convergence studies are conducted on functionally graded cylindrical shells under various influencing factors such as boundaries, spring parameters et al. The present method apparently has rapid convergence ability and excellent stability, and the results of the paper are closely agreed with those obtained by FEM and published literatures.

In-Stent Stenosis of Stent Assisted Endovascular Treatment on Intracranial Complex Aneurysms

  • Yoon, Kyeong-Wook;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.485-489
    • /
    • 2010
  • Objective : To introduce the frequency and segment analysis of in-stent stenosis for intracranial stent assisted endovascular treatment on complex aneurysms. Methods : A retrospective study was performed in 158 patients who had intracranial complex aneurysms and were treated by endovascular stent application with or without coil embolization. Of these, 102 patients were evaluated with catheter based angiography after 6, 12, and 18 months. Aneurysm location, using stent, time to stenosis, stenosis rate and narrowing segment were analyzed. Results : Among follow-up cerebral angiography done in 102 patients, 8 patients (7.8%) were shown an in-stent stenosis. Two patients have unruptured aneurysm and six patients have ruptured one. Number of Neuroform stents were 7 cases (7.5%) and Enterprise stent in 1 case (11.1%). Six patients demonstrated in-stent stenosis at 6 months after stent application and remaining two patients were shown at 12 months, 18 months, respectively. Conclusion : In-stent stenosis can be confronted after intracranial stent deployment. In our study, no patient showed symptomatic stenosis and there were no patients who required to further treatment except continuing antiplatets medication. In-stent stenosis has been known to be very few when they are placed into the non-pathologic parent artery during the complex aneurysm treatment, but the authors found that it was apt to happen on follow up angiography. Although the related symptom was not seen in our cases, the luminal narrowing at the stented area may result the untoward hemodynamic event in the specific condition.

Effects of Local Anesthetics on Electron Transport and Generation of Superoxide Radicals in Mitochondria (국소마취제가 Mitochondria에서의 전자이동 및 Superoxide Radicals의 생성에 미치는 영향)

  • Lee, Chung-Soo;Shin, Yong-Kyoo;Lee, Kwang-Soo
    • The Korean Journal of Pharmacology
    • /
    • v.23 no.2
    • /
    • pp.113-121
    • /
    • 1987
  • Local anesthetics were investigated for their effects on mitochondrial electron transport system, production of superoxide radical from submitochondrial particles and malondialdehyde production through lipid per oxidation. Local anesthetics had various effects on activities of enzymes in electron transport chain. The activities of NADH dehydrogenase, NADH oxidase and NADH-ubiquinone oxidoreductase were effectively inhibited by lidocaine, procaine and dibucaine but slightly influenced by cocaine. The activities of succinate dehydrogenase, succinate-cytochrome c oxidoreductase and succinate-ubiquinone oxidoreductase were inhibited by lidocaine and dibucaine, but the succinate oxidase activity was stimulated by local anesthetics. Both dihydroubiquinone-cytochrome c oxidoreductase and cytochrome c oxidase activities were inhibited by local anesthetics. In these reactions, the response of Complex I segment to local anesthetics was greater than other Complex segments. Local anesthetics inhibited both the superoxide production from submitochondrial particles supplemented with succinate or NADH and the enhanced production of superoxide radicals by antimycin. The malondialdehyde production by oxygen free radicals was inhibited by local anesthetics. These results suggest that the inhibition of superoxide and malondialdehyde production caused by local anesthetics may be brought by suppression of the electron transport in mitochondria at sites in or near complex I segment.

  • PDF

A Study on the Automatic Diagnosis of ECG

  • Jeong, Gu-Young;Yu, Kee-Ho;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.55.4-55
    • /
    • 2001
  • Analyzing the ECG signal, we can find heart disease. Myocardial ischemia is a disorder of cardiac function caused by insufficient blood flow to the muscle tissue of the heart. Myocardial ischemia is inscribed on ST-segment of the ECG during and after patient takes exercise or is under stress, but after long time past, the ECG pattern is return to steady state. Therefore, it is necessary to monitor and analyze the ECG signal continuously for patient or aged people. Our primary purpose is the detection of temporary change of the ST-segment of ECG automatically. In the signal processing, the wavelet transform decomposes the ECG signal into high and low frequency components using wavelet function. Recomposing the high frequency bands including QRS complex, we can detect QRS complex more easily ...

  • PDF

Realtime Wireless Monitoring of Abnormal ST in ECG Using PC Based System

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun;Inooka, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.176-180
    • /
    • 2004
  • The ST-segment that the beginning part of T wave is the important diagnostic parameter to finding myocardial ischemia. Abnormal ST appears in two types. One is the level change, and the other is the pattern change. In this paper, we describe the monitoring of abnormal ST using PC based system. Hardware of this system consists of transmitter, receiver and PC. The function of transmitter is measuring ECG in three channels which are selected manually and transmitting the data to receiver by digital radio way. Connection with receiver and PC is by RS232C, and the data received on the PC is analyzed automatically by ECG analysis algorithm and saved to file. In the algorithm part for detecting abnormal ST, ST-segments are approximated by a polynomial. This method can detect all of the deviation and pattern change of ST-segment regardless the change in the heart rate or sampling rate. To gain algorithm reliability, the method rejects distorted polynomial approximation by calculation the difference between the approximated ST-segment and original ST-segment. In pre-signal processing, the wavelet transformation separates high frequency bands including QRS complex from the original ECG. Consequently, the process improves the performance of detecting each feature points.

  • PDF

P Wave Detection based on QRST Cancellation Zero-One Substitution

  • Cho, Ik-Sung
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2021
  • Cardiac arrhythmias are common heart diseases and generally cause sudden cardiac death. Electrocardiogram (ECG) is an effective tool that can reveal the electrical activity of the heart and diagnose cardiac arrhythmias. We propose detection of P waves based on QRST cancellation zero-one substitution. After preprocessing, the QRST segment is determined by detecting the Q wave start point and T wave end point separately. The Q wave start point is detected by digital analyses of the QRS complex width, and the T wave end point is detected by computation of an indicator related to the area covered by the T wave curve. Then, we determine whether the sampled value of the signal is in the interval of the QRST segment and substitute zero or one for the value to cancel the QRST segment. Finally, the maximum amplitude is selected as the peak of the P wave in each RR interval of the residual signal. The average detection rate for the QT database was 97.67%.