• Title/Summary/Keyword: comparison measurement

Search Result 3,155, Processing Time 0.027 seconds

Interlaboratory Comparison of Critical Current Measurements on Ag-sheathed Bi-2223 tapes (Bi-2223선재의 임계전류 측정기술 비교)

  • Lee, Kyu-Won;Han, Gi-Youl
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.99-103
    • /
    • 2001
  • We have conducted two runs of interlaboratory comparison on Ag-sheathed Bi-2223 tapes to evaluate the level of measurement techniques for the critical current measurement. Two classes of specimens were prepared for parallel and serial routings and sent to four participating laboratories. The critical currents of specimens were measured at 77 K in zero magnetic field. In the first comparison, we used twenty different Bi-2223 tapes as specimens for comparison and participating laboratories measured the specimens using their own instruments and procedures. As a result, the scattering of data on the first comparison showed -3.0% to +l2.2% for the parallel routing and -0.7% to +l5.1% for the serial routing. Major sources of these variations were attributed to different measurement techniques. Thus, the second comparison of measurement was done on the same specimens under specified measurement conditions, particularly in terms of cooling procedure and sweep rate of the test current. The variations for the second comparison were decreased -3.1% to +3.2% far the parallel routing and -1.8% to +7.7% fur the serial routing.

  • PDF

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

The comparison of the basic human body measurement definitions and anthropometric terms between KS and ISO (인체 측정 방법 및 측정 항목에대한 KS와 ISO의 비교)

  • 이영숙;김동진;남경희;안병덕;이관석
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.247-255
    • /
    • 1997
  • In this study, the comparison of the basic human body measurement definitions and anthropometric terms between the Korean Standard and the International Standard. Measurement definitions, measurement method and measurement terms of the international standard ISO 8559, 7250 were compard with the KSRI-88-103-IR. We have tried to suggest the new methods and new terms such as eye height, waist height, arm length.

  • PDF

A comparative analysis of measurement domain of elementary school mathematics curriculum in Korea and Japan: centered on extensive quantity (우리나라와 일본의 초등학교 수학과 교육과정 측정 영역 비교·분석: 외연량을 중심으로)

  • Lee, Seung Eun;Lee, Jeong Eun;Park, Kyo Sik
    • Journal of the Korean School Mathematics Society
    • /
    • v.21 no.1
    • /
    • pp.19-37
    • /
    • 2018
  • In this study, the actual state of teaching seven extensive quantities (time, length, capacity, weight, area, angle measure, volume) of measurement domain are analyzed comparatively between the 2015 revised elementary school mathematics curriculum in Korea and the 2017 revised elementary school mathematics curriculum in Japan in terms of comparison in measurement, direct measurement, indirect measurement, and estimation in measurement. From the results of this comparative analysis, some implications for discussion on the development of the next elementary school mathematics textbook and the next elementary mathematics curriculum can be suggested. First, it is necessary to discuss on clarifying the range of handling of comparison, direct measurement, indirect measurement, estimation of seven extensive quantities respectively. Second, it is necessary to discuss on doing direct comparison when intuitive comparison is difficult. Third, it is necessary to discuss on reconsidering indirect comparison of weights. Fourth, it is necessary to discuss on reconsidering measurement using arbitrary units in case of angular measures. Fifth, it is necessary to discuss on dealing with estimating the area of $1cm^2$ and $1m^2$ and the volume of $1cm^3$ and $1m^3$ for the purpose to make rough guesses their size respectively.

A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System (지역난방배관의 누수감지 신뢰성 향상에 관한 연구)

  • 신춘식;안영주;변기식
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.66-72
    • /
    • 1999
  • Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe. the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.

  • PDF

A System for Measuring 3D Human Bodies Using the Multiple 2D Images (다중 2D 영상을 이용한 3D 인체 계측 시스템)

  • 김창우;최창석;김효숙;강인애;전준현
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.5
    • /
    • pp.1-12
    • /
    • 2003
  • This paper proposes a system for measuring the 3D human bodies using the multiple 2D images. The system establishes the multiple image input circumstance from the digital camera for image measurement. The algorithm considering perspective projection leads us to estimate the 3D human bodies from the multiple 2D images such as frontal. side and rear views. The results of the image measurement is compared those of the direct measurement and the 3D scanner for the total 40 items (12 heights, 15 widths and 13 depths). Three persons measure the 40 items using the three measurement methods. In comparison of the results obtained among the measurement methods and the persons, the results between the image measurement and the 3D scanner are very similar. However, the errors for the direct measurement are relatively larger than those between the image measurement and the 3D scanner. For example, the maximum errors between the image measurement and the 3D scanner are 0.41cm in height, 0.39cm in width and 0.95cm in depth. The errors are acceptable in body measurement. Performance of the image measurement is superior to the direct. because the algorithm estimates the 3D positions using the perspective projection. In above comparison, the image measurement is expected as a new method for measuring the 3D body, since it has the various advantages of the direct measurement and 3D scanner in performance for measurement as well as in the devices, cost, Portability and man power.

The effects of GCM ankle joint therapy on Shoulder and Neck (전신조정술 발목관절치료가 어깨와 목에 미치는 영향)

  • Hyoung In-Hyouk;Ahn Mock;Bae Sung-Soo;Mun Sang-Eun;Chae Jung-Byung
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.479-487
    • /
    • 2003
  • Tje purpose of this study is to understand body as a whole concept through examining effects of distant shoulder and neck with GCM ankle joint therapy. The twenty three subject with ankle joint therapy and comparison groups without ankle joint therapy were authorized the score of before and after therapy by correspondence T-test using pump lines and tapes as instruments. The results are as follows. 1. The test group had change of shoulder in measurement 1, 2, 3 and were regarded statistically 1st measurement on left, 2nd on right.(p<.05) 2. The test group had change of neck in measurement 1, 2, 3 and were regarded statistically 2nd on left on right.(p<.05) 3. In the comparison group the comparison of shoulder height was not regarded statistically all at 1, 2 comparison on left and regarded statistically all at 1, 2 comparison on right.(p<.05) 4. In the comparison group the comparison of neck height was not regarded statistically both left and right at 1, 2 comparison.(p<.05)

  • PDF

A Study of Form Measurement using Noncontact Sensor (비접촉식 센서를 사용한 형상 측정 연구)

  • 송정섭;황윤호;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

A Logical Framework of Comparison Shopping Effectiveness and Comparison Challenge Methodology

  • Lee, Jae-Won
    • Proceedings of the CALSEC Conference
    • /
    • 2005.03a
    • /
    • pp.130-134
    • /
    • 2005
  • This research describes the comparison broker's role and its effectiveness measurement using a developed logical framework of comparison shopping service. And verifies that seller-led comparison challenge method provide comparison information of products to buyers more efficiently. In electronic commerce, buyer's satisfaction of purchase (S) can be defined as an interactive function between seller's competitiveness vector (P) of products that supplied to the market, and buyer's informed level vector (B) of products that is known from a lot of sources. Then the buyer's informed level can be changed through the information analysis among products by transformation process using comparison matrix (C). So the role of comparison shopping is to construct a comparison matrix and to serve it to the buyers, and to change the buyer's informed level. The changed informed level influences a buyer's satisfaction, that improved satisfaction of purchase is defined as the effectiveness of comparison shopping. As a perfect provision and usage of comparison matrix is impossible cause of cognitive limit, the most efficient method for improving the comparison effectiveness is the comparison challenge that detects the comparison elements of the largest buyer's information efficiency, and then to be compared between elementary products selectively. This research verifies the substantial superiority of comparison challenge through television market data experiments.

  • PDF

Precise Comparison of Two-dimensional Dopant Profiles Measured by Low-voltage Scanning Electron Microscopy and Electron Holography Techniques

  • Hyun, Moon-Seop;Yoo, Jung-Ho;Kwak, Noh-Yeal;Kim, Won;Rhee, Choong-Kyun;Yang, Jun-Mo
    • Applied Microscopy
    • /
    • v.42 no.3
    • /
    • pp.158-163
    • /
    • 2012
  • Detailed comparison of low-voltage scanning electron microscopy and electron holography techniques for two-dimensional (2D) dopant profiling was carried out with using the same multilayered p-n junction specimen. The dopant profiles obtained from two methods are in good agreement with each other. It demonstrates that reliability of dopant profile measurement can be increased through precise comparison of 2D profiles obtained from various microscopic techniques.