• Title/Summary/Keyword: communication networks

Search Result 5,470, Processing Time 0.035 seconds

Blind Source Separation for OFDM with Filtering Colored Noise and Jamming Signal

  • Sriyananda, M.G.S.;Joutsensalo, Jyrki;Hamalainen, Timo
    • Journal of Communications and Networks
    • /
    • v.14 no.4
    • /
    • pp.410-417
    • /
    • 2012
  • One of the premier mechanisms used in extracting unobserved signals from observed mixtures in signal processing is employing a blind source separation (BSS) algorithm. Orthogonal frequency division multiplexing (OFDM) techniques are playing a prominent role in the sphere of multicarrier communication. A set of remedial solutions taken to mitigate deteriorative effects caused within the air interface of OFDM transmission with aid of BSS schemes is presented. Four energy functions are used in deriving the filter coefficients. Energy criterion functions to be optimized and the performance is justified. These functions together with iterative fixed point rule for receive signal are used in determining the filter coefficients. Time correlation properties of the channel are taken advantage for BSS. It is tried to remove colored noise and jamming components from themixture at the receiver. Themethod is tested in a slow fading channel with a receiver containing equal gain combining to treat the channel state information values. The importance is that, these are quite low computational complexity mechanisms.

Performance Analysis of Multi-Hop Decode-and-Forward Relaying with Selection Combining

  • Bao, Vo Nguyen Quoe;Kong, Hyung-Yun
    • Journal of Communications and Networks
    • /
    • v.12 no.6
    • /
    • pp.616-623
    • /
    • 2010
  • In this paper, exact closed-form expressions for outage probability and bit error probability (BEP) are presented for multi-hop decode-and-forward (DF) relaying schemes in conjunction with cooperative diversity, in which selection combining technique is employed at each node. We have shown that the proposed protocol offers remarkable diversity advantage over direct transmission as well as the conventional DF relaying schemes with the same combining technique. We then investigate the system performance when different diversity schemes are employed. It has been observed that the system performance loss due to selection combining relative to maximal ratio combining is not significant. Simulations are performed to confirm our theoretical analysis.

An Improved Priority Application for Humanoid Robot in the Controller Area Network(CAN) (CAN내장 휴머노이드 로봇에 대한 진보된 우선순위 적용)

  • Ku Ja-bong;Huh Uk-youl;Kim Jin-geol;Kim Byung-yoon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.10
    • /
    • pp.714-719
    • /
    • 2004
  • The Controller Area Network (CAN) is being widely used in real-time control applications such as automobiles, aircraft, and automated factories. Unfortunately, CAN, in its current form, is not able to either share out the system bandwidth among the different devices fairly or to grant an upper bound on the transmission times experienced by the nodes connected to the communication medium as it happens, for instance, in the token-based networks. In this paper. we present the message scheduling for CAN, based on the distributed control scheme to integrate actuators and sensors in a humanoid robot. Besides introducing the new algorism, this paper also presents some performance figures obtained using a specially developed software simulator, while the behavior of the new algorism is compared with the traditional CAN systems, in order to see how effective they are.

Application of On-line Diagnostic System for Oil-filled Power Transformers (대용량 변압기 예방진단 시스템 적용 사례)

  • Kim Y.H.;Lee C.R.;Hwangbo S.W.;;Shin Y.T.;Park K.S.;Lee J.B.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.590-593
    • /
    • 2004
  • This paper presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on YeoSu thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

Performance Analysis of Multi-Gigabit Wireless Transmission at THz WLAN-Type Applications

  • Choi, Yonghoon
    • Journal of Communications and Networks
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2014
  • Optimal position of access point (AP) is important for multi-gigabit wireless transmission in terahertz (THz) wireless local area network (WLAN)-type applications, where there exist the THz characteristic multiple clusters in channel propagation. By considering the multiple clusters in THz indoor communications, this paper investigates the optimal AP position when two APs are issued for increasing the system capacity. Numerical results reveal that the central position of each AP within each half service region, which offers the shortest cumulated path length for line-of-sight paths, is optimal to achieve the maximal system capacity.

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment (전자파 검출에 의한 전력기기 On-Line 열화 측정시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kim, C.W.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1664-1666
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

Study On The Protective Effect of Lightning Surge for Electronic Equipments According to Installation Methods of Surge Protective Device (서지보호소자의 설치방식에 따른 기기의 뇌보호효과 검토)

  • Lee, Suck-Woo;Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.616-619
    • /
    • 2004
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society. And electronic equipments contained electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit in electronic equipments and AC power lines are becoming more widely. To achieve effective method of surge protection, there are needs for correlation between lightning surge protective effect of electronic equipment and installation method of surge protective device. This paper describes as a result of experiments for correlation between lightning surge protective effect and installation method of surge protective device.

  • PDF

Propagation Aspect of Lightning Surge According to The Arrangement of Indoor wire (옥내배선 배치에 따른 서지 전파양상)

  • Lee, Suck-Woo;Whang, Kyu-Hyun;Seo, Ho-Joon;Rhie, Dong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.658-661
    • /
    • 2004
  • Lightning surge damages of low voltage equipments in building are increasing due to increase in electrical and communication networks in the information-oriented society And electrical circuits with semiconductor are very weak against lightning surge. To achieve effective method of surge protection on low voltage lines, there are needs for the relationship between propagation aspects of lightning surge and arrangement of indoor wire. This paper describes the experimental study on the relationship between them. This result may be raw data for establishment of surge protection system.

  • PDF

An Controller Area Network(CAN) Application for Humanoid Robot (휴머노이드 로봇에 대한 CAN 적용)

  • Ku, Ja-Bong;Huh, Uk-Youl;Kim, Jin-Geol
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2400-2402
    • /
    • 2004
  • The Controller Area Network (CAN) is being widely used in real-time control applications such as automobiles, aircraft, and automated factories. Unfortunately, CAN, in its current form, is not able to either share out the system bandwidth among the different devices fairly or to grant an upper bound on the transmission times experienced by the nodes connected to the communication medium as it happens, for instance, in the token-based networks. In this paper, we present the message scheduling for CAN, based on the distributed control scheme to integrate actuators and sensors in a humanoid robot. Besides introducing the new algorithm, this paper also presents some performance figures obtained using a specially developed software simulator, while the behavior of the new algorithm is compared with the traditional CAN systems, in order to see how effective they are.

  • PDF

Real Time Control for Robot Manipulator Using Transputer (트랜스퓨터를 이용한 로보트 매니퓰레이터의 실시간 제어)

  • Jang, Yong-Geun;Hong, Suk-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.397-400
    • /
    • 1992
  • Many dynamic control have been proposed; however, most of them are limited within stage of simulation study. The main reason is that the computations required for inverse dynamics are far beyond the ability of the present commercially available microprocessors. In this paper, In order to achieve real-time processing in robot dynamic control, a parallel processing computer for robot dynamic control is implemented using two transputer. Two transputer compute two degree of freedom robot. The transputer is a special purpose MPU for parallel processing. Transputers are used in networks to build a high performance concurrent system. A network of transputers and peripheral controllers is constructed using point-to-point communication. To gain most benifit from the transputer architecture, the whole system is programmed in OCCAM which is a high level language for concurrent applications. This control algorithm is applied to the RHINO SCARA type manipulator. We could taked about 438.6 microseconds to compute robot dynamic with two-processors.

  • PDF