• Title/Summary/Keyword: combustibles

Search Result 130, Processing Time 0.022 seconds

Characteristics of Municipal Solid Wastes Generation in a Small City -For Donghae City- (소규모 도시의 생활폐기물 발생특성 -동해시를 중심으로-)

  • Kim, Seung-Ho;Won, Chul-Hee;Kim, Byoung-Ug;Rim, Jay-Myoung
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.103-108
    • /
    • 2002
  • This research was performed to investigate the generation and physico-chemical characteristics of municipal solid wastes. The results were as follows: i) The generation rate and bulk density were 0.157 kg/cap/d and 147.8 g/L in residential zone, respectively. In non-residential zone, the generation and bulk density were 1.71 kg/cap/d and 85.6 g/L, respectively. Consequently, bulk density of non-residential zone was lower than that of residential zone. ii) The wastes consisted of 90% of combustibles and 10% of incombustibles in residential zone. And the wastes from non-residential zone was composed 85% of combustibles and 15% of incombustibles. iii) Water content was estimated at 47~50% in residential zone and restaurants. In non-residential zone, except restaurants, water content was in the range of 10~30%. Ash content was nearly 10% in overall zone.

  • PDF

Fire Characteristics of Circuit Breakers for Low Voltage during Switching Arcs according to the Characteristics of Combustibles (가연물 특성에 따른 저압용 차단기의 스위치 아크에 의한 화재특성)

  • Kim, Dong-Woo;Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Choi, Chung-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.37-38
    • /
    • 2006
  • In this paper, the fire characteristics of circuit breakers for low voltage during switching arcs were analyzed according to the characteristics of combustible materials. Arc dispersion and ignition process were taken by high speed imaging system and digital camera. In this experiment, four resistors were connected as loads. To discover the fire characteristics of circuit breakers by combustible materials, ethanol and cotton were installed as combustibles near contacts respectively. In case of ethanol, fire broke out near the contacts while switch was turned on and turned off. Whereas, in case of cotton, fire broke out near deteriorated contacts while switch was turned off.

  • PDF

Influences of changes in the Thermal Properties on Pyrolysis of Solid Combustibles (열물성의 변화가 고체 가연물의 열분해에 미치는 영향)

  • Hong, Ter-Ki;Lee, Jong Won;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.41-48
    • /
    • 2017
  • In order to investigate the influence of changes in the thermal properties of solid combustibles on thermal decomposition, a series of solid pyrolysis experiments were performed using a cone calorimeter specified in KS F ISO 5660-1. In the present study, Poly Methyl Methacrylate (PMMA) which does not produce Char during pyrolysis process was used as solid fuel. Results obtained from cone calorimeter experiments were compared to ones obtained from numerical analysis of Fire Dynamics Simulator (FDS) 1D pyrolysis model adopted with thermal properties of solid fuel as input parameters. Comparisons between experimentally calculated and model-predicted mass loss rate were then made to elucidate the effect of changes in the thermal properties on pyrolysis of PMMA.

Improvement Proposal for the Fire Suppression Systems of Open Parking Lots (개방형주차장의 소방설비 개선 제안)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • In cars, the amount of combustibles, such as plastics, textiles, etc., have increased dramatically to improve the fuel efficiency of cars by reducing the gross vehicle weight according to the increases in an oil price and to reduce environmental problems. One or two cars were involved in a parking lot fire prior to the mid-2000 s. On the other hand, there were many parking lot fires where the entire car was destroyed due to increasing the use of plastics. In this study, the quantity of combustibles in a car was 316.2 kg over a total weight 1935 kg. This is 16.34% of total weight and 10 times greater than that three decades earlier. When a sprinkler is installed as a parking lot fire protection system as a substitute for water spray, the water discharge of the sprinkler must maintain the original density of water spray, $20lpm/m^2$. In addition, the use of a hose reel $CO_2$ system at pilotis parking lots must be prohibited because the hose reel $CO_2$ system has no adaptability for a car fire. Instead, this study proposes foam, dry powder, loaded stream systems be used in parking lot fire suppression systems.

Evaluation of Design Fire Curves for Single Combustibles in a Cinema Complex (복합영상관 단일 가연물의 디자인 화재곡선 평가)

  • Jang, Hyo-Yeon;Hwang, Cheol-Hong;Oh, Chang Bo;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.18-27
    • /
    • 2020
  • An actual fire test was performed on single combustibles placed in a local cinema complex, and quantitative differences in the maximum heat release rate (HRR) and fire growth rate were investigated based on the design fire curve methods (i.e., the general and 2-stage methods). In terms of combustible use and fire load, a total of 12 combustibles were selected, classified into cinema lounge and movie theater. It was found that the maximum HRR and fire growth rate determined using the two-stage method were quantitatively different from those of the general method. The application of the two-stage method, which can be used to determine the fire growth rate of the initial fire stage more precisely, could be useful in accurately predicting the activation time of fire detectors and fire-extinguishing facilities, as well as the available safe egress time (ASET) and required safe egress time (RSET).

Experimental Study on the Effect of Flow around Solid Combustibles and Thermal Thickness on Heat Release Rate Characteristics (고체 가연물 주위의 유동과 열적 두께의 변화가 열방출률 특성에 미치는 영향에 관한 실험적 연구)

  • Hong, Ter-Ki;Seo, Dong-Pyo;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.28-34
    • /
    • 2020
  • In this study, an ISO 5660-1 cone calorimeter experiment was conducted to examine the effects of changes in flow and thermal thickness around solid combustibles on heat release rate characteristics. Polymethyl methacrylate (PMMA) is a solid combustible material that does not generate char during the combustion reaction. Hence, it was selected for the experiment, and the thermal penetration depth was calculated to distinguish the thermal thickness of PMMA. Furthermore, the thermal decomposition characteristics were analyzed by measuring the heat release rate measured during the combustion of PMMA. This was performed after generating the forced flow around the combustibles by setting the duct flow of the cone calorimeter to 12, 24, and 40 L/s. The results confirmed that the thermal release rate of the thermally thin combustible material was not significantly affected by the change in the surrounding flow. Hence, the thermally thick combustible material was significantly affected by the change in the flow rate.

Sensitivity analysis of input variables to establish fire damage thresholds for redundant electrical panels

  • Kim, Byeongjun;Lee, Jaiho;Shin, Weon Gyu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.84-96
    • /
    • 2022
  • In the worst case, a temporary ignition source (also known as transient combustibles) between two electrical panels can damage both panels. Mitigation strategies for electrical panel fires were previously developed using fire modeling and risk analysis. However, since they do not comply with deterministic fire protection requirements, it is necessary to analyze the boundary values at which combustibles may damage targets depending on various factors. In the present study, a sensitivity analysis of input variables related to the damage threshold of two electrical panels was performed for dimensionless geometry using a Fire Dynamics Simulator (FDS). A new methodology using a damage evaluation map was developed to assess the damage of the electrical panel. The input variables were the distance between the electrical panels, the vertical height of the fuel, the size of the fire, the wind speed and the wind direction. The heat flux was determined to increase as the vertical distance between the fuel and the panel decreased, and the largest heat flux was predicted when the vertical separation distance divided by one half flame length was 0.3-0.5. As the distance between the panels increases, the heat flux decreases according to the power law, and damage can be avoided when the distance between the fuel and the panel is twice the length of the panel. When the wind direction is east and south, to avoid damage to the electrical panel the distance must be increased by 1.5 times compared to no wind. The present scale model can be applied to any configuration where combustibles are located between two electrical panels, and can provide useful guidance for the design of redundant electrical panels.

Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment (반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석)

  • Gyu Bin Kim;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.

Separation Characteristic and Recycling of Excavated Materials Containing Waste (폐기물혼입굴착물의 선별특성과 재활용성 평가)

  • Lee, Suyoung;Kim, Kyuyeon;Jeon, Taewan;Shin, Sunkyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.5-12
    • /
    • 2019
  • The study is carried out to survey the proper management and to propose an eco - friendly separation system through efficient screening and resource recovery of excavated materials containing waste from various excavating fields such as reconstruction of landfill sites for reuse, reclamation of unsanitary landfill and residential land development of waste dumping sites. The current status and screening process and analytical characteristics of the excavated materials containing waste were reviewed. Through the analysis of the samples such as separated combustibles, recyclable soils and residues collected from the on-site visits we were able to understand the characteristics of separated materials and excavated materials containing waste such as calorific value, elementary composition, TOC, foreign material content and LOI. It has been found that elimination of the moisture of excavations, removal of attached soil from the surfaces of the excavated combustibles and the quantitative supply method of the input devices are the main operating factors as essential factors for the optimal separation of excavated materials containing waste. For efficient management and recycling of excavated materials containing, it is necessary to set criteria of ash content in separated combustibles and criteria organic matter content in separated soils.

연기성상에 따른 감도특성 시험보고

  • Jeong, Yang-Heon;Lee, Bok-Yeong;Yu, In-Ho
    • Fire Protection Technology
    • /
    • s.17
    • /
    • pp.10-14
    • /
    • 1994
  • Since it is extremely of importance that the automatic fire detection systems are reliable and able to operate properly in case of fire, they are subjucted to test on the variety of combustibles.

  • PDF