• 제목/요약/키워드: combination resonance

검색결과 224건 처리시간 0.021초

자기공명영상촬영용 경사자계코일의 3차원설계 (3-Dimensional Design of Gradient Coils for Magnetic Resonance Imaging)

  • 류연철;현정호;이흥규;오창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.235-237
    • /
    • 2006
  • In this paper, the previous 2-D gradient coil design method using loop current elements is extended to 3-D or multi-layer structures which is useful for various MRI applications including MR microscopic imaging where relatively large space may be available for the implementation of the gradient coils. Either the power consumption or the stored energy (thus, inductance), or the combination of the two can be minimized with a set of chosen target field constraints. Complete 3-D design equations for the optimization as well as inductance or resistance calculation are derived. An effective coil shape correction method for a curved current pattern is also developed. The design method can also be easily extended to the active shielding structure.

  • PDF

Properties of Interlayer Low Dielectric Polyimide during Aluminum Etching with Electron Cyclotron Resonance Etcher System

  • Kim, Sang-Hoon;Ahn, Jin-Ho
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.87-96
    • /
    • 2000
  • The properties of polyimide for interlayer dielectric applications are investigated during plasma etching of aluminum on it. Chlorine-based plasma generally used for aluminum etching results in an increase in the (dielectric constant of polyimide, while $SF_6$ plasma exhibits a high polyimide etch rate and a reducing effect of the dielectric constant. The leakage current of polyimide is significantly suppressed after plasma exposure. An optimal combination of Al etch with $Cl_6$ plasma and polyimide etch with $SF_6$ plasma is expected to be a good tool for realizing multilevel metallization structures.

  • PDF

V-형 선형 초음파 모터의 구동 특성 (Driving Characteristic of Ultrasonic Linear Motor With V-type)

  • 정성수;박태곤
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.425-429
    • /
    • 2007
  • A linear ultrasonic motor was designed by a combination of the longitudinal and bending mode. linear ultrasonic motors are based on an elliptical motion on the surface of elastic body, such as bar or plates. The corresponding eigen-mode of one resonance frequency can be excited twice at the same time with a phase shift of 90 degrees in space and time. That is excite symmetric and anti-symmetric modes. Then it determines the thrust and speed of the motor. Linear ultrasonic motors are investigated experimentally in according to be fabricated a general classification to motor structure and material characteristic. There was the first to simulate as use of finite element analysis ANSYS 9.0. The AL-T2W8-ARM14-LEG18-ANGLE80 motor has a maxim efficiency 18 % under the speed 0.14 m/s, thrust 345 gf and preload 280 gf, operating frequency is 57.6 kHz.

전자 스핀 공명을 이용한 메로시아닌 색소 LB막의 특성 (Characteristics of Meroeyanine Dye LB Films Using Electron Spin Resonance Spectroscopy)

  • 신훈규;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1569-1571
    • /
    • 1996
  • The role of ESR spectroscopy in the characterization of functional LB films is discussed. Optical absorption were performed on LB films of binary mixtures of three kinds of merocyanine dyes where DS and 6Me-DS form J-like aggregates but not DO in single component films. The observed optical absorption spectra of mixed films were markedly dependant on the combination of dyes. We found the formation of J-aggregates in a mixed merocyanine dyes containing a non J-aggregate forming dye DO, in a single component case. In structural studios, ESR is of particular important in the analysis of molecular orientation of LB films. Development of new functional LB films may provide more cases where ESR spectroscopy will clarify the nature of such films.

  • PDF

Feasibility of Proton Chemical Shift Imaging with a Stereotactic Headframe

  • 백현만;최보영;손병철;정성택;이형구;서태석
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.86-86
    • /
    • 2003
  • Purpose: To prove feasibility of proton chemical shift. imaging (1H CSI) during stereotactic procedure, authors peformed 1H CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, evaluated the pathologic results Materials and methods: The 1H CSI directed stereotactic biopsy was performed in five patients. 1H CSI was performed before conventional stereotactic MRI with gadolinium enhancement for stereotactic coordinates. The metabolite images expressed as integral ratios, Cho/Cr and Lac/Cr, were displayed in different colors. The stereotactic target coordinates were correlated with the coordinates from the 1H CSI images.

  • PDF

Structural Analysis of Black Common Bean (Phaseolus vulgaris L.) Anthocyanins

  • Choung, Myoung-Gun
    • Food Science and Biotechnology
    • /
    • 제14권5호
    • /
    • pp.672-675
    • /
    • 2005
  • Two anthocyanins were isolated from 1% HCl-20% methanol extracts of KG 97287 black common bean (Phaseolus vulgaris L.) using semipreparative, high-performance liquid chromatography (HPLC). The anthocyanins were identified using a combination of LC/ES-mass spectrometry (MS) and spectroscopic methods of UV-Vis, $^1H-$ and $^{13}C-$ nuclear magnetic resonance (NMR). The chemical structures of these two anthocyanins were elucidated as delphinidin 3-glucoside and petunidin 3-glucoside and their contents in KG 97287 black common bean seed coats were determined to be $2.614{\pm}0.11$ and $0.167{\pm}0.01\;mg/g$, respectively. These contents were lower than reported internationally and we recommend the introduction into Korea of high anthocyanin varieties of black common bean.

THE FUKUSHIMA DISASTER - SYSTEMIC FAILURES AS THE LACK OF RESILIENCE

  • Hollnagel, Erik;Fujita, Yushi
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.13-20
    • /
    • 2013
  • This paper looks at the Fukushima disaster from the perspective of resilience engineering, which replaces a search for causes with an understanding of how the system failed in its performance. Referring to the four resilience abilities of responding, monitoring, learning, and anticipating, the paper focuses on how inadequate engineering anticipation or risk assessment during the design, in combination with inadequate response capabilities, precipitated the disaster. One lesson is that systems such as nuclear power plants are complicated, not only in how they function during everyday or exceptional conditions, but also during their whole life cycle. System functions are intrinsically coupled synchronically and diachronically in ways that may affect the ability to respond to extreme conditions.

Metabolic Discrimination of Safflower Petals of Various Origins Using 1H NMR Spectroscopy and Multivariate Statistical Analysis

  • Whang, Wan-Kyun;Lee, Min-Won;Choi, Hyung-Kyoon
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.557-560
    • /
    • 2007
  • The metabolic discrimination of safflowers from various geographical origins was performed using 1H nuclear magnetic resonance (NMR) spectroscopy followed by principal components analysis. With a combination of these techniques, safflower samples from different origins could be discriminated using the first two principal components (PC) of the 1H NMR spectra of the 50% methanol fractions. PC1 and PC2 accounted cumulatively for 91.3% of the variation in all variables. The major peaks in the 1H NMR spectra that contributed to the discrimination were assigned to fatty acid (terminal CH3), lactic acid, acetic acid, choline derivatives, glycine, and safflower yellow derivatives. In this study, we suggest that various types of safflower can be discriminated using PCA and 1H NMR spectra.

진단방사선에서의 자기공명분광 (Radiology of Magnetic Resonance Spectroscopy)

  • Park, Bo-Young
    • 한국의학물리학회지:의학물리
    • /
    • 제3권2호
    • /
    • pp.33-42
    • /
    • 1992
  • 과학분야에서 가장 획기적인 방법중의 하나로 각광받는 자기공명분광의 기본적인 원리가 의학분야의 진단방사선에서 유망한 방법론으로 소개되었다. 자기공명의 다양한 응용은 의학에서 보다 정확하고 민감한 정밀 진단의 가능성을 시사한다. 자기공명영상의 해부학적 정보와 자기공 명분광의 생화학적 정보의 결합은 진단방사선의 밝은 전망을 제시한다.

  • PDF

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF