• Title/Summary/Keyword: color Doppler ultrasonography

Search Result 40, Processing Time 0.02 seconds

Renal hemodynamics in dogs with experimental hydronephrosis treated with transarterial embolization of renal artery (신장동맥색전술을 실시한 개의 실험적 수신증의 혈동학)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.413-419
    • /
    • 2001
  • This study was performed to evaluate the renal hemodynamics using color Doppler ultrasonography in dogs with unilateral experimental hydronephrosis treated with transarterial embolization of the renal artery (TAE-RA). Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. The mean resistive index (RI) value of kidney was significantly increased at 4, 9, 17 days after ligation of ureter. Unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$body temperature, pulse, and respiratory rate were within normal ranges during procedures. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. In color Doppler ultrasonographic findings, there was no blood flow into the embolized kidneys treated by TAE-RA, however, blood flow signal was found in contralateral normal kidney of dogs treated with TAE-RA compared to that of normal kidney in normal control group. It is concluded that TAE-RA does not affect the hemodynamics of contralateral normal kidney in dogs with experimental hydronephrosis and color Doppler ultrasonography is simple and non-invasive modality for the monitoring of the revascularization of the renal artery after TAE-RA.

  • PDF

The Impacts of Piezoelectric Elements' Defects On Color & Power Doppler Images (초음파 프로브에서 소자결함이 컬러 및 파워 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2015
  • An ultrasound probe has a big impact on Doppler images even though it has very high risk of frequent function-breakdowns occurring in medical ultrasound scanners. This study experimentally analyses the impacts of an ultrasonic probe's defected elements on power & color Doppler images. The results show that, the bigger the size of defected probe elements is, and the closer a group of action elements is to the center, the more the brightness of images and the velocity of Doppler diminish. When elements' defects increase in color & power Doppler images, false images are formed to be mistaken for blood-vessel plaque in neighboring regions. Accordingly, whenever element defects are suspected, we need check-up process in B-mode. From this respective, it is advisable to have primary interest in a probe and carry out continuous probe QA for ultrasonography.

The efficacy of ultrasonography in monitoring the healing of jaw lesions

  • Zainedeen, Obai;Haffar, Iyad Al;Kochaji, Nabil;Wassouf, George
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose: This study aimed to assess the reliability of ultrasonography (US) in comparison with cone-beam computed tomography (CBCT) as a tool for monitoring the healing of jaw lesions. Materials and Methods: Twenty-one radiolucent lesions in jaws referred to the Oral Surgery Department at our institution were selected for this study. All lesions underwent CBCT and US examinations. The anteroposterior, superoinferior, and mesiodistal dimensions of the lesions were measured on CBCT and US images before surgery and at 6 months after surgery. The dimensions were compared between the US and CBCT images. Blood-flow velocity around the lesions was measured by color Doppler before surgery and at 1 week and 6 months after surgery to assess the capability of US to show changes in blood-flow velocity around the lesion. Results: Before surgery, there were no significant differences between US and CBCT in the mesiodistal and anteroposterior dimensions, although a significant difference was found in the superoinferior dimension (P<.05). However, at 6 months after surgery, significant differences were found between US and CBCT in all dimensions, and it is likely that the US measurements more accurately reflected the extent of healing. The average blood-flow velocity increased at 1 week after surgery (5.84 cm/s) compared with the velocity before surgery (4 cm/s) (P<.05). Then, at 6 months after surgery, the blood-flow velocity significantly decreased (3.53 cm/s) compared to the velocity measured at 1 week after surgery (P<.05). Conclusion: US with color Doppler was confirmed to be a more efficient tool than CBCT for monitoring bone healing.

Radiographic and Ultrasonographic Diagnosis of Single Intrahepatic Portosystemic Shunt in a Dog (개의 단순 간내성 간문맥전신단락증의 영상진단학 및 치료 1예)

  • 전혜영;장동우
    • Journal of Veterinary Clinics
    • /
    • v.20 no.4
    • /
    • pp.508-515
    • /
    • 2003
  • A 4-month-old 5.7 kg male Golden retriever with history of seizure, depression, lethargy and anorexia was referred to Veterinary Medical Teaching Hospital, Chungbuk National University. Hematologic examination revealed microcytosis and nonregenerative anemia. Serum chemical values showed increased serum ammonia (423 $\mu$mol/L), ALP (1101 U/L), r-GTP (13.9 U/L) and CPK (1454 U/L), and decreased total protein (4.9 g/dl) and BUN (1.6 mg/dl). Microhepatia was shown in survey abdominal radiographs. Color doppler ultrasonographic examination revealed dilated tortuous vein with turbulent flow within liver parenchyma. Intraoperative jejunoportography and intraoperative ultrasonography confirmed the location and size of single intrahepatic shunt vessel in the left medial liver lobe. Also, the anomalous vessel entering the caudal vena cava was identified beneath the diaphragm. The shunting vessel was ligated with using an Ameroid constrictor. General conditions, hematologic and serum chemical values resolved gradually after surgery. One month after surgery abdominal radiograph showed normal gastric axis and it was consistent whit the normal size liver. Normal echogenecity of liver and enlargement of portal vein were shown in ultrasonography. It is assumed that survey radiography and ultrasonography are useful for diagnosis of single intrahepatic shunt in a dog and especially jejunoportography vein portography and intraoperative ultrasonography are suitable for confirmation of the anatomic location and size of the shunting vessels.

Peroneal Artery Perforator-Based Propeller Flaps for Reconstruction of Soft Tissue Defect around the Ankle Joint: A Report of Four Cases (비골 동맥 천공지 기저 프로펠러 피판술을 이용한 족관절 주위 연부조직 결손의 재건술: 4예 보고)

  • Cho, Byung-Ki;Park, Ji-Kang;Park, Kyoung-Jin;Chong, Suri
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.4
    • /
    • pp.222-226
    • /
    • 2014
  • Four patients with soft tissue defects around the ankle joint were covered with peroneal artery perforator-based propeller flaps. Using color Doppler sonography, the flap was designed by considering the location of the perforator and soft tissue defects. The procedure was then performed by rotating the flap by $180^{\circ}$. Additional skin graft was required in a patient due to partial necrosis, and delayed wound repair was performed in another patient with poor blood circulation at the distal part of the flap. The remaining patients did not have any complications and results were considered excellent. Good outcomes were eventually obtained for all patients.

Unusual Presentation of a Testicular Lymphoma Mimicking a Missed Testicular Torsion: A Case Report (계류 고환염전으로 오인된 드문 형태의 고환 림프종: 증례 보고)

  • Mi Jin Kim;Young Hwan Lee;Youe Ree Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1287-1291
    • /
    • 2021
  • Testicular lymphoma is an uncommon testicular tumor that usually presents as a painless mass. It usually shows hypervascularity on color Doppler ultrasound (US) and a mild enhancement on enhanced CT or MRI. We present an unusual case of a testicular lymphoma mimicking a missed testicular torsion in a 67-year-old male patient with right scrotal swelling and intermittent pain for 2 months. Color Doppler US demonstrated the absence of vascularity in the enlarged right testis, and the initial diagnosis was a missed testicular torsion. CT demonstrated a poorly enhancing mass rather than a missed testicular torsion with enhanced small nodular foci at the periphery. The final pathological diagnosis was testicular lymphoma.

Pseudoaneurysm of Ulnar Artery after Endoscopic Carpal Tunnel Release

  • Ryu, Sung-Joo;Kim, In-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.380-382
    • /
    • 2010
  • The authors present an extremely rare case of a pseudoaneurysm of the ulnar artery as a complication of a two-portal endoscopic carpal tunnel release (ECTR). A 70-year-old man with chronic renal failure and on maintenance hemodialysis with a left arteriovenous fistula presented with paresthesia of his right hand. A clinical diagnosis of right carpal tunnel syndrome was confirmed by ultrasonography and an electro physiologic study. He underwent two-portal ECTR, and the paresthesia was much improved. However, he presented to us one month after operation with severe pain, a tender mass distal to the right wrist crease and more aggravation of the paresthesia in the ulnar nerve distribution. Doppler ultrasound was performed and revealed a hypo echoic lesion 20 mm in diameter in the right palm, with arterial Doppler flow inside connected to the palmar segment of the ulnar artery. An ulnar artery pseudoaneurysm was diagnosed and treated by ultrasound-guided percutaneous thrombin injection. Transverse color Doppler ultrasound image showed complete thrombosis of the pseudoaneurysm and flow cessation after a total injection of 500 units of thrombin. The symptoms were also improved.

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

Midgut Volvulus of Infant Simulating Intussusception Diagnosis with Color Doppler Ultrasonography (장중첩증의 임상양상을 보였던 영아의 중장 염전증(Midgut volvulus) 1례 -복부 초음파검사를 이용한 진단-)

  • Lee, Hae-Kyoung;Kim, Je-Woo;Oh, Phil-Soo;Lee, Young-Ah;Choi, Ha-Joo;Yun, Hea-Sun;Yang, Ik;Lee, Kyung-Won;Lee, Jae-Jung
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.1 no.1
    • /
    • pp.133-137
    • /
    • 1998
  • Although midgut volvulus is clinically characterized by bilous vomiting and abdominal distention, plain abdominal X-ray is usually non-specific and therefore it can be misdiagnosed to other diseases. Upper gastrointestinal contrast study and computed tomography have been used as a routine diagnostic tool but it takes cost and time. Abdominal ultrasonography is a relatively good alternatives in diagnosing midgut volvulus and it relatively saves cost and time. But case presentation of midgut volvulus diagnosed with abdominal ultrasonography are rarely found in literature. We experienced a 6 month old girl who had come to our hospital with bilous vomiting and was diagnosed as midgut volvulus with ultrasonography. Thus we report this case with the presentation of typical ultrasonographic findings of midgut volvulus.

  • PDF

The Etiologic Diseases and Diagnostic Usefulness of Color Doppler Ultrasonography in Children with Chronic Coughs (소아 만성 기침의 원인 질환과 컬러 도플러 초음파 검사의 진단적 유용성)

  • Park, Sun Young;Lee, Joon Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.489-497
    • /
    • 2002
  • Purpose : The objectives of this study were to investigate the causes of chronic cough and to establish the appropriate diagnostic approach to chronic cough in children. Methods : One hundred and thirty two cases of chronic cough were prospectively evaluated. They visitors to pediatric chronic cough clinics at Kang-nam saint Mary's Hospital of Catholic University from August 2000 to July 2001 for 12 months. Careful history taking by questionnaire, physical examination, radiologic studies of chest and sinus, hematologic and immunologic studies, allergic skin tests, and methacholine challenge tests were performed. Color doppler(CD) ultrasonography were performed and compared with simultaneous 24 Hr. esophageal pH monitoring to diagnose gastroesophageal reflux disease(GERD). Results : Age distributions were demonstrated that nine in infants, 82 in early childhood, 38 in late childhood, and three in adolescence. Common causes of chronic cough were bronchial asthma in 40 cases, chronic sinusitis in 22 cases, GERD in seven cases, bronchial asthma combined with sinusitis in 28 cases, bronchial asthma combined with GERD in 14 cases, psychogenic cough in two. cases, foreign body in one case, chronic bronchitis in one case, and bronchiolitis in one case. Comparing with 24 Hr. pH monitoring, sensitivity, specificity, positive predictive value and negative predictive values of CD ultrasonography were 88%, 69%, 85 %, and 73% respectively. Conclusion : The most common causes of chronic cough in children were bronchial asthma, sinusitis and GERD in order. We suggest that CD ultrasonography can be used as a good, convenient screening method for patients with suspected GERD in outpatient settings.